Event Notification Report for May 11, 2018

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
05/10/2018 - 05/11/2018

EVENT NUMBERS
5339853399

Power Reactor
Event Number: 53398
Facility: WATTS BAR
Region: 2     State: TN
Unit: [] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: CHUCK BROESCHE
HQ OPS Officer: DONALD NORWOOD
Notification Date: 05/11/2018
Notification Time: 15:19 [ET]
Event Date: 05/11/2018
Event Time: 10:11 [EDT]
Last Update Date: 05/11/2018
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(C) - POT UNCNTRL RAD REL 50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
FRANK EHRHARDT (R2DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 58 Power Operation 58 Power Operation
Event Text
CONTAINMENT SHIELD BUILDING INOPERABLE

"At 1011 EDT on May 11, 2018, Containment Shield Building Annulus differential pressure exceeded the required limit. The Shield Building was declared inoperable requiring entry into Technical Specification (TS) 3.6.15 Conditions A and B. The event was initiated by failure of the operating annulus vacuum fan. Main Control Room Operators manually started the stand-by annulus vacuum fan to recover pressure. Shield Building Annulus differential pressure was restored to the required value at 1016 EDT and TS 3.6.15 Condition A and B were exited on May 11, 2018 at 1016 EDT.

"The failure mechanism for the annulus vacuum fan is being investigated.

"The Containment Shield Building ensures the release of radioactive material from the containment atmosphere is restricted to those leakage paths and associated leakage rates assumed in the accident analysis during a Loss of Coolant Accident (LOCA). The Emergency Gas Treatment System (EGTS) would have automatically started and performed its design function to maintain the Shield Building Annulus differential pressure within required limits.

"The event is being reported pursuant to 10 CFR 50.72(b)(3)(v)(C) and 10 CFR 50.72(b)(3)(v)(D). The NRC Resident has been notified."


Power Reactor
Event Number: 53399
Facility: GRAND GULF
Region: 4     State: MS
Unit: [1] [] []
RX Type: [1] GE-6
NRC Notified By: WESLEY MARSHALL
HQ OPS Officer: OSSY FONT
Notification Date: 05/12/2018
Notification Time: 06:58 [ET]
Event Date: 05/11/2018
Event Time: 23:27 [CDT]
Last Update Date: 05/12/2018
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
MARK HAIRE (R4DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Refueling 0 Refueling
Event Text
INADVERTENT ACTUATION OF THE EMERGENCY DIESEL GENERATOR

"On 5/11/2018, at 2327 hours CDT, with the plant in Mode 5, Grand Gulf Nuclear Station was making preparations for surveillance test 06-OP-1P75-R-0003, Standby Diesel Generator 1 Functional Test. The Grand Gulf Nuclear Station experienced an auto-start of the Division 1 [Emergency] Diesel Generator [EDG] when the 15AA Bus Potential Transformer (PT) fuse drawer was racked out instead of the line PT fuse drawer for Bus 15AA feeder breaker 152-1514. This resulted in the 15AA Incoming Feeder Breaker 152-1511 from Engineered Safety Features Transformer 12 opening, de-energizing the 15AA Bus. The Division 1 EDG started and energized Bus 15AA. The Division 1 LSS SYSTEM FAIL annunciator was received and Standby Service Water A failed to start due to the 15AA Bus PT fuse drawer being racked out. Standby Gas Treatment Train B was manually initiated per the Loss Of AC Power Off Normal Emergency Procedure. Station equipment operated as expected based on the PT fuse drawer that was racked out.

"The Division 1 EDG was manually tripped from the Control Room because cooling from the Standby Service Water A was not available.

"RHR [residual heat removal] B was in Shutdown Cooling [mode] and was verified not affected"

The licensee has notified the NRC Resident Inspector.