Event Notification Report for December 08, 2017

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
12/07/2017 - 12/08/2017

EVENT NUMBERS
5310853109

Power Reactor
Event Number: 53108
Facility: LIMERICK
Region: 1     State: PA
Unit: [] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: RACHEL HEATH
HQ OPS Officer: VINCE KLCO
Notification Date: 12/08/2017
Notification Time: 17:25 [ET]
Event Date: 12/08/2017
Event Time: 13:10 [EST]
Last Update Date: 12/08/2017
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
CHRISTOPHER CAHILL (R1DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 100 Power Operation
Event Text
HIGH PRESSURE COOLANT INJECTION INOPERABLE DUE TO A LEAKING CHECK VALVE

"U/2 HPCI [Unit 2/High Pressure Coolant Injection] was declared inoperable due to leak by of the pump discharge check valve after pump shutdown from flow testing. This resulted in cycling of the minimum flow valve. The discharge valve was closed to prevent the continued cycling of the minimum flow valve. This condition was identified during normal surveillance testing."

The licensee notified the NRC Resident Inspector.


Agreement State
Event Number: 53109
Rep Org: KANSAS DEPT OF HEALTH & ENVIRONMENT
Licensee: INTEGRA TECHNOLOGIES
Region: 4
City: WICHITA   State: KS
County:
License #: GL
Agreement: Y
Docket:
NRC Notified By: JAMES UHLEMEYER
HQ OPS Officer: VINCE KLCO
Notification Date: 12/08/2017
Notification Time: 17:26 [ET]
Event Date: 12/08/2017
Event Time: 15:20 [CST]
Last Update Date: 12/08/2017
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
THOMAS HIPSCHMAN (R4DO)
NMSS_EVENTS_NOTIFICA (EMAI)
ILTAB (EMAI)
Event Text
AGREEMENT STATE REPORT - LOST POLONIUM SOURCE

The following information was excerpted from an email received from the State of Kansas:

The licensee is reporting that an ionizer containing a radioactive source (Model Number P-2063-1000) was lost. The licensee currently has 3 other ionizers of the same model. The device radioactive source was Polonium-210 (SN: A2KT674) with an activity of 31.5 mCi and was last leak tested on 9/20/2016. The device was checked out by the licensee and placed within the secure test floor while testing electrical devices at the Integra Technologies facility. The missing device use was last logged on 8/25/2017. The licensee believes that their maintenance department mistakenly threw the device away. Upon discovering that the device was missing, the licensee searched their facility several times over without finding the device. The prevention for further loss is that the remaining 3 units will be mounted in permanent locations using security screws so they cannot be removed by unauthorized personnel.

THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf