Skip to main content

Event Notification Report for November 28, 2017

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
11/27/2017 - 11/28/2017

EVENT NUMBERS
5309753100

Agreement State
Event Number: 53097
Rep Org: TEXAS DEPT OF STATE HEALTH SERVICES
Licensee: INTERTECK ASSET INTEGRITY MANAGEMENT, INC.
Region: 4
City: LONGVIEW   State: TX
County:
License #: 06801
Agreement: Y
Docket:
NRC Notified By: ART TUCKER
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 11/30/2017
Notification Time: 00:00 [ET]
Event Date: 11/28/2017
Event Time: 00:00 [CST]
Last Update Date: 12/19/2017
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
NEIL OKEEFE (R4DO)
NMSS_EVENTS_NOTIFICA (EMAI)
PATRICIA MILLIGAN (INES)
Event Text
AGREEMENT STATE REPORT - RADIOGRAPHY TRAINEE OVEREXPOSURE

The following report was received via e-mail:

"On November 28, 2017, the Agency [Texas Department of State Health Services] was contacted by the licensee's Radiation Safety Officer (RSO) who reported that on November 28, 2017, they were notified by their dosimetry processor that one of their radiographer trainee's exposure badges was reported to read 62 Rem. The RSO stated the trainee was returning to the Longview office from West Texas to be interviewed. The badge reading was for the month of October 2017. The RSO stated the trainee had operated the radiography camera crank out device, but had not changed out any film. It is believed the dose is to the badge only. The RSO stated they had not observed any adverse health effects in the trainee. On November 29, 2017, the Agency contacted the RSO and requested additional information. The RSO stated the trainee stated that they had not dropped their dosimeter and accidently exposed it. The trainee had stated that they had been wearing an alarming rate meter and it had never alarmed. The trainee's daily exposure record did not indicate any abnormal exposures. The radiographer supervising the trainee did not recall any abnormal operations while supervising the trainee. The RSO stated the trainee had not received any type of medical treatments during the exposure period. The RSO stated they were considering sending blood samples to REAC/TS for analysis. The RSO stated the dosimetry processor reported the exposure to the badge was angular. The RSO stated the trainee has been assigned duties that would not give them any additional exposure.

"The licensee will provide the Agency [Texas Department of State Health Services] any information gathered in the interview with the trainee. The RSO cannot state with certainty that the exposure is not real, therefore the Agency is providing this report to the Nuclear Regulatory Commission. Additional information will be provided as it is received in accordance with SA-300."

Texas Incident #: I-9523


* * * UPDATE ON 12/12/2017 AT 0955 EST FROM ART TUCKER TO STEVEN VITTO * * *

The following report was received via e-mail:

"On November 28, 2017, the Agency was contacted by the licensee's RSO who reported that the OSL [Optically stimulated luminescence] badge reading for one of their radiographer trainees was reported to read 62 rem. On December 8, 2017, the Agency interviewed the individual with the high badge reading and the licensee's radiation safety officer (RSO). The interviews did not provide any additional information that would explain the high badge reading. The RSO stated a blood sample from the individual was submitted to Radiation Emergency Assistance Center/Training Site (REAC/TS) on December 5, 2017. Additional information will be provided as it is received in accordance with SA-300."

R4DO (Deese), INES Officer (Milligan), and NMSS Events Group have been notified.


* * * UPDATE ON 12/19/2017 AT 0828 EST FROM ART TUCKER TO ANDREW WAUGH * * *

The following report was received via e-mail:

"On December 18, 2017, the licensee [Interteck Asset Integrity Management Inc.] reported 'I have received the test report and the result is negative. No dicentric chromosome was observed in a total of 500 metaphase cells analyzed.' indicating the exposure was to the badge only. Additional information will be provided as it is received in accordance with SA-300."

Notified R4DO (Pick), INES Officer (Milligan), and NMSS Events Group via email.


Agreement State
Event Number: 53100
Rep Org: TEXAS DEPT OF STATE HEALTH SERVICES
Licensee: EXXONMOBIL OIL CORPORATION
Region: 4
City: BEAUMONT   State: TX
County:
License #: 00603
Agreement: Y
Docket:
NRC Notified By: ART TUCKER
HQ OPS Officer: DAVID AIRD
Notification Date: 11/30/2017
Notification Time: 00:00 [ET]
Event Date: 11/28/2017
Event Time: 00:00 [CST]
Last Update Date: 12/01/2017
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
NEIL OKEEFE (R4DO)
NMSS_EVENTS_NOTIFICA (EMAI)
Event Text
AGREEMENT STATE REPORT - TWO NUCLEAR GAUGES INVOLVED IN FIRE

The following report was received via E-mail:

"On November 30, 2017, the Agency [Texas Department of State Health Services] was notified by the licensee's consultant that two nuclear gauges were involved in a fire on November 28, 2017. The consultant stated they could not gain access to the gauges until this date. The gauges are Thermo Fisher model 5203 gauges containing a two (2) curie (original activity) cesium-137 source. The consultant stated the dose rate on one of the gauges was reading 180 millirem an hour on a preliminary radiation survey. This dose rate appears to be higher than normal. A contamination survey was performed in the area of the gauges, but the results were not available at the time of the report. The gauges are located 20 - 30 feet above the ground and do not create an exposure risk to any individuals. Additional information will be provided as it is received in accordance with SA-300."

Texas Incident #: I-9524


* * * UPDATE AT 0740 EST ON 12/1/2017 FROM ART TUCKER TO MARK ABRAMOVITZ * * *

The following information was received via E-mail:

"The licensee has provided the following additional information:

"The source holders are visibly intact, however they are black with soot. Both of the gauges were surveyed. For B-1228 the readings are normal but B-1227 has a localized spot on the lower left-hand location of the shield where the readings are 180 mR/hr at contact and 14 mR/hr at 1 ft. Additional shielding has been attached to the lower left hand location of the shield to reduce the dose rate to 3 mR/hr at 1 ft. Sealed Source leak tests have been performed and the results will be communicated as soon as they are assayed. No personnel (member of the general public or radiation workers) have been within 5 feet of either source due to the unsafe structural conditions due to the fire. Additional information will be provided as it is received in accordance with SA-300."

Notified the R4DO (O'Keefe) and NMSS Events Notification (via e-mail).


* * * UPDATE FROM ART TUCKER TO DONALD NORWOOD AT 1511 EST ON 12/1/2017 * * *

The following information was received via E-mail:

"The licensee reported that the results of the leak test performed on the two gauges indicated the sources were not leaking (less than 0.0001 microCi). Additional information will be provided as it is received in accordance with SA-300."

Notified the R4DO (O'Keefe) and NMSS Events Notification (via e-mail).