Event Notification Report for November 03, 2017

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
11/02/2017 - 11/03/2017

EVENT NUMBERS
530525305353051

Power Reactor
Event Number: 53052
Facility: INDIAN POINT
Region: 1     State: NY
Unit: [] [3] []
RX Type: [2] W-4-LP,[3] W-4-LP
NRC Notified By: OVIDIO RAMIREZ
HQ OPS Officer: JEFF HERRERA
Notification Date: 11/03/2017
Notification Time: 21:08 [ET]
Event Date: 11/03/2017
Event Time: 20:22 [EDT]
Last Update Date: 11/06/2017
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
RAY MCKINLEY (R1DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
3 A/R Y 100 Power Operation 0 Hot Standby
Event Text
INDIAN POINT UNIT 3 REACTOR TRIP ON LOW STEAM GENERATOR LEVEL

"On November 3rd, 2017 at 2022 EDT, the Indian Point Unit 3 Reactor Protection system automatically actuated at 100 percent power. Annunciator first out indication was from 33 SG [Steam Generator] Low Level. This automatic reactor trip is reportable to the NRC under 10 CFR 50.72(b)(2)(iv)(B). All control rods fully inserted on the reactor trip. All safety systems responded as expected. The Auxiliary Feedwater System actuated as expected. Offsite power and plant electrical lineups are normal. All plant equipment responded normally to the unit trip. No primary or secondary code safeties lifted during the trip.

"The Auxiliary Feedwater System actuated following the automatic trip as expected. This is reportable under 10 CFR 50.72(b)(3)(iv)(A). The Emergency Diesel Generators did not start as offsite power remained available and stable. The Unit remains on offsite power and all electrical loads are stable. Unit 3 is in Hot Standby at normal operating temperature and pressure with decay heat removal using auxiliary feedwater to the steam generators and normal heat removal through the condenser via the high pressure steam dumps. Unit 2 was unaffected and remains at 100 percent power.

"A post trip investigation is in progress."

The licensee indicated that Radiation Monitor number 14 spiked twice during the transient, however, is currently not indicating any signs of radiation.

The licensee will notify the NRC Resident Inspector and the NY Public Service Commission.

* * * UPDATE AT 1523 EST ON 11/06/17 FROM RAMIREZ OVIDIO TO JEFF HERRERA * * *

"The initial notification stated that Indian Point Unit 3 Reactor Tripped on 33 SG [Steam Generator] Low Level, this is incorrect. Indian Point Unit 3 Reactor Tripped on a Turbine Trip. The Turbine Trip was caused by a Generator Back-up Lockout Relay. The Turbine Trip was the 'first' annunciator first-out but was acknowledged instead of silenced during initial operator actions. The Turbine Trip first-out being acknowledged allowed a Low Steam Generator first-out to later annunciate. A Low Steam Generator Level is an expected condition post trip.

"This update does not change any actions taken by the operating team or required notifications under 10 CFR 50.72(b)(2)(iv)(B) and 10 CFR 50.72(b)(3)(iv)(A).

"A post trip investigation remains in progress.

"The licensee will notify the NRC Resident Inspector and the NY Public Commission."

Notified the R1DO(Cook)


Power Reactor
Event Number: 53053
Facility: PEACH BOTTOM
Region: 1     State: PA
Unit: [2] [3] []
RX Type: [2] GE-4,[3] GE-4
NRC Notified By: SARAH AFARIAN
HQ OPS Officer: JEFF HERRERA
Notification Date: 11/04/2017
Notification Time: 14:00 [ET]
Event Date: 11/03/2017
Event Time: 16:49 [EDT]
Last Update Date: 11/04/2017
Emergency Class: NON EMERGENCY
10 CFR Section:
26.719 - FITNESS FOR DUTY
Person (Organization):
RAY MCKINLEY (R1DO)
FFD GROUP (EMAI)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 100 Power Operation
3 N N 0 Refueling 0 Refueling
Event Text
FITNESS FOR DUTY - LICENSED EMPLOYEE CONFIRMED POSITIVE FOR FITNESS FOR DUTY

A licensed employee had a confirmed positive test for a controlled substance during a random fitness-for-duty test. The employees plant access has been placed on administrative hold.

The NRC Resident Inspector has been notified.


!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 53051
Facility: DAVIS BESSE
Region: 3     State: OH
Unit: [1] [] []
RX Type: [1] B&W-R-LP
NRC Notified By: TOM COBBLEDICK
HQ OPS Officer: JEFF HERRERA
Notification Date: 11/03/2017
Notification Time: 00:00 [ET]
Event Date: 11/03/2017
Event Time: 00:00 [EDT]
Last Update Date: 12/14/2017
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
HIRONORI PETERSON (R3DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
STATION VENT RADIATION MONITOR EFFICIENCY FACTOR NON-CONSERVATIVE

"On 11/3/17, with the unit operating in Mode 1 at approximately 100 percent power, an issue was identified with the Station Vent Radiation Monitors. The noble gas channels utilize an efficiency factor for isotope Kr-85 instead of the required Xe-133. For the normal range radiation monitors, the efficiency factor is non-conservative, resulting in both monitors being declared inoperable at 1045 hours EDT. As a result, the Normal Control Room Ventilation System was shut down and isolated, and the Control Room Emergency Ventilation System started in accordance with Technical Specification Required Actions at 1122 hours.

"The inoperability of both Station Vent Normal Range Radiation Monitors represents a condition that at the time of discovery could have prevented the fulfillment of the safety function of a system needed to mitigate the consequences of an accident. The Station Vent Accident Range Monitors also utilize an efficiency factor for Kr-85 instead of Xe-133, but for the Accident Range Monitors the efficiency factor is conservative. Because alternate means exist to determine release rate, which include use of grab samples and field surveys, this degraded capability does not represent a major loss of emergency assessment capability.

"The NRC Resident Inspector has been notified."


* * * RETRACTION FROM NICK DOWNING TO DONALD NORWOOD AT 0927 EST ON 12/14/2017 * * *

"On 11/3/2017, the efficiency factors for the Station Vent Normal and Accident Range Radiation Monitors were revised to the proper setting for the required isotope, the normal range monitors were declared Operable, and the Control Room Normal Ventilation System was returned to service.

"An evaluation of the issue with the Station Vent Normal Range Radiation Monitors was performed, which determined the Control Room Ventilation isolation setpoint is well below the point at which the dose to the Control Room Operators would exceed General Design Criteria (GDC) limits following a Design Bases Accident. The error introduced from using an incorrect efficiency value did not challenge the margin to the GDC limits; therefore, the Station Vent Normal Range Monitors remained operable, and this issue did not prevent the monitors from fulfilling their safety function to mitigate the consequences of an accident.

"The NRC Resident Inspector has been notified."

Notified R3DO (Stone).