Event Notification Report for October 13, 2017

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
10/12/2017 - 10/13/2017

EVENT NUMBERS
530155301253014

Power Reactor
Event Number: 53015
Facility: PALO VERDE
Region: 4     State: AZ
Unit: [1] [2] [3]
RX Type: [1] CE,[2] CE,[3] CE
NRC Notified By: DELBERT ELKINTON
HQ OPS Officer: DAN LIVERMORE
Notification Date: 10/14/2017
Notification Time: 16:37 [ET]
Event Date: 10/13/2017
Event Time: 19:48 [MST]
Last Update Date: 10/14/2017
Emergency Class: NON EMERGENCY
10 CFR Section:
26.719 - FITNESS FOR DUTY
Person (Organization):
THOMAS HIPSCHMAN (R4DO)
FFD GROUP (EMAI)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Refueling 0 Refueling
2 N Y 100 Power Operation 100 Power Operation
3 N Y 100 Power Operation 100 Power Operation
Event Text
FITNESS FOR DUTY - NON LICENSED SUPERVISOR FAILED RANDOM DRUG TEST

"At approximately 19:48 Mountain Standard Time on October 13, 2017, Palo Verde Nuclear Generating Station (PVNGS) staff confirmed a non-licensed supervisor tested positive for drugs during a random 'Fitness for Duty' test. The person's access authorization was terminated in accordance with station procedures."

The NRC resident inspector has been notified by the licensee.


Non-Agreement State
Event Number: 53012
Rep Org: IDAHO STATE UNIVERSITY
Licensee: IDAHO STATE UNIVERSITY
Region: 4
City: POCATELLO   State: ID
County: BANNOCK
License #: 1127380-01
Agreement: N
Docket: 030-32-3
NRC Notified By: RICH BREY
HQ OPS Officer: KARL DIEDERICH
Notification Date: 10/13/2017
Notification Time: 15:46 [ET]
Event Date: 10/13/2017
Event Time: 00:00 [MDT]
Last Update Date: 10/13/2017
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2201(a)(1)(i) - LOST/STOLEN LNM>1000X
Person (Organization):
THOMAS HIPSCHMAN (R4DO)
NMSS_EVENTS_NOTIFICA (EMAI)
CNSC (CANADA) (FAX)
Event Text
LOST OR MISSING MATERIAL

A series 50 nuclear accident dosimeter S/N AP237 with a 1 gram 62 mCi Pu-239 source was determined missing on 10/13/17. The dosimeter was one of 14 received by Idaho State University from the Department of Energy (DOE) in 1991. In 2003, this particular dosimeter was found to have detectable surface contamination and determined to have a compromised source. The device was removed from local inventory in 2003 pending transfer. Attempts were made to transfer the device to Idaho National Lab (INEL), but were declined. The device is believed to have been placed in the Idaho State University nuclear waste stream, and may have been transferred in 2006 or 2011 with other waste via Thomas Gray to US Ecology, but there are no supporting records. Investigation is ongoing.

THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf


!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 53014
Facility: BROWNS FERRY
Region: 2     State: AL
Unit: [1] [] []
RX Type: [1] GE-4,[2] GE-4,[3] GE-4
NRC Notified By: STEWART WETZEL
HQ OPS Officer: RICHARD SMITH
Notification Date: 10/13/2017
Notification Time: 22:46 [ET]
Event Date: 10/13/2017
Event Time: 17:00 [CDT]
Last Update Date: 06/08/2018
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
STEVE ROSE (R2DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
ACCIDENT MITIGATION - HIGH PRESSURE COOLANT INJECTION DECLARED INOPERABLE

"On October 13, 2017 at 1700 CDT, Unit 1 High Pressure Coolant Injection (HPCI) was declared Inoperable due to discovery of a leak on a sensing line to 1-PCV-073-0043, Lube Oil Cooler & Gland Seal Condenser Pressure Control Valve. The leak is a steady stream located where the sense line connects to the valve.

"This constitutes an unplanned HPCI System inoperability and requires an 8 hour ENS notification in accordance with 10 CFR 50.72(b)(3)(v)(D), due to the failure of a single train system affecting accident mitigation and a 60 day written report in accordance with 10 CFR 50.73(a)(2)(v)(D)."

The NRC Resident Inspector has been notified by the Licensee.

* * * RETRACTION ON 6/8/18 AT 1500 EDT FROM BILL BALL TO BETHANY CECERE * * *

"ENS Event Number 53014, made on 10/13/2017 is being retracted.

"NRC notification 53014 was made to ensure that the Eight-Hour Non-Emergency reporting requirements of 10 CFR 50.72 were met when a leak on a threaded union, along with piping vibration, was identified on U1 HPCls Lube Oil Cooler & Gland Seal Condenser Pressure Control Valve sensing line (1-PCV-073-0043).

"A Past Operability Evaluation [POE] was performed under CR# 1347736. The evaluation concluded that HPCI was degraded, but met the threshold for TS operability. Specifically the vibrations shown were evaluated and deemed to not impact pipe integrity. These vibrations were also evaluated for seismic events. Based on this the POE concluded that HPCI was capable of performing its intended safety function for its designed mission time.

"As such, the circumstances discussed in the report did not result in any condition that at the time of discovery could have prevented the fulfillment of the safety function of structures of system that are needed to remove residual heat. Thus, there was no impact on nuclear safety. Therefore, this event is not reportable under 10 CFR 50.72(b)(3)(v)(B).

"TVA's evaluation of this event notification is documented in the corrective action program.

"The licensee has notified the NRC Resident lnspector."

Notified R2DO (Ernstes).