Skip to main content

Event Notification Report for July 20, 2017

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
07/19/2017 - 07/20/2017

EVENT NUMBERS
52865

Power Reactor
Event Number: 52865
Facility: DAVIS BESSE
Region: 3     State: OH
Unit: [1] [] []
RX Type: [1] B&W-R-LP
NRC Notified By: WARREN CLEVELAND
HQ OPS Officer: DAN LIVERMORE
Notification Date: 07/20/2017
Notification Time: 13:30 [ET]
Event Date: 07/20/2017
Event Time: 12:30 [EDT]
Last Update Date: 07/20/2017
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(ii)(B) - UNANALYZED CONDITION 50.72(b)(3)(v)(A) - POT UNABLE TO SAFE SD
Person (Organization):
LAURA KOZAK (R3DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
POTENTIAL TORNADO MISSILE VULNERABILITIES

"In order to address the concerns outlined in RIS 2015-06 'TORNADO MISSILE PROTECTION,' an evaluation of tornado missile vulnerabilities and their potential impact on Technical Specification (TS) plant equipment was conducted. This evaluation concluded that the following Structures, Systems, and Components (SSCs) are potentially vulnerable to tornado generated missiles:

"The Davis-Besse Nuclear Power Station (DBNPS) Unit 1 Emergency Diesel Generator (EDG) Fuel Oil Storage Tanks (FOST) (DB-Tl53-l, DB-T-153-2) support the EDG operation for 7 days. The vents on the FOST are necessary to support the transfer of fuel from the FOST to the EDG day tank. These vents are not protected and are vulnerable to a potential tornado-generated missile impact. This postulated strike could impact fuel transfer to the EDG day tank and, therefore does not support operability of both EDGs for Technical Specification 3.8.1.

"Tornado generated missiles striking the FOST vent piping could potentially affect pump performance and challenge the structural integrity of the tank. This would render both the FOST and corresponding EDG inoperable. This condition is reportable per 10 CFR 50.72(b)(3)(ii)(B) and 10 CFR 50.72(b)(3)(v)(A).

"The potential vulnerabilities for the FOST vents (as discussed above) are being addressed in accordance with NRC EGM-15-002 Revision 1 and DSS-ISG-2016-01 NRC enforcement discretion and interim guidance documents. Immediate compensatory measures were taken to mitigate the potential consequences of an onsite tornado generated missile impact on the FOST vents."

The licensee notified the NRC Resident Inspector.