Skip to main content

Event Notification Report for June 28, 2017

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
06/27/2017 - 06/28/2017

EVENT NUMBERS
52835528315283252849

Agreement State
Event Number: 52835
Rep Org: TEXAS DEPT OF STATE HEALTH SERVICES
Licensee: ACUREN INSPECTION SERVICES
Region: 4
City: LA PORTE   State: TX
County:
License #: 01774
Agreement: Y
Docket:
NRC Notified By: ART TUCKER
HQ OPS Officer: JEFF HERRERA
Notification Date: 06/29/2017
Notification Time: 15:58 [ET]
Event Date: 06/28/2017
Event Time: 00:00 [CDT]
Last Update Date: 06/29/2017
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
RAY KELLAR (R4DO)
NMSS_EVENTS_NOTIFICA (EMAI)
Event Text
AGREEMENT STATE REPORT - UNABLE TO RETRACT SOURCE DUE TO CRIMPED GUIDE TUBE

The following report was received from the Texas Department of State Health Services via email:

"On June 29, 2017, the Agency [Texas Department of State Health Services] was notified by a licensee's radiation safety officer (RSO) that one of his radiography crews experienced an event. The radiographers were testing a 24 inch pipe and the shoots required the use of an extension on the guide tube and the use of a stand. While retracting the 56 curie iridium-192 source back to the QSA 880D camera, the stand fell on the guide tube extension crimping it far enough that the source could not be retracted beyond the crimp. The radiographers set up new boundaries and contacted the RSO. The RSO stated the source was driven to the end of the guide tube and shielding was placed over the source. The guide tube extension was removed from the camera and disconnected from the guide tube. The crank out assembly was dismantled and the drive cable was pulled through the camera and guide tube extension. The cable was inserted through the camera and the source retracted into the exposure device. The individual who recovered the source received 287 millirem (as indicated on their self-reading dosimeter.) The equipment was delivered to the manufacturer for inspection and repair or disposal. Additional information will be provided as it is received in accordance with SA-300.

"Texas Incident Number: I9499"


Agreement State
Event Number: 52831
Rep Org: MARYLAND DEPT OF THE ENVIRONMENT
Licensee: MARYLAND STATE HIGHWAY ADMINISTRATION
Region: 1
City: HANOVER   State: MD
County:
License #: MD-03-114-01
Agreement: Y
Docket:
NRC Notified By: ALAN JACOBSON
HQ OPS Officer: BETHANY CECERE
Notification Date: 06/28/2017
Notification Time: 09:49 [ET]
Event Date: 06/28/2017
Event Time: 07:15 [EDT]
Last Update Date: 07/05/2017
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
RAY POWELL (R1DO)
NMSS_EVENTS_NOTIFICA (EMAI)
DENNIS ALLSTON (ILTA)
BERNARD STAPLETON (IRD)
Event Text
AGREEMENT STATE REPORT - STOLEN MOISTURE DENSITY GAUGE

The following is excerpted from an email from the Maryland Department of the Environment:

On 06/28/2017 at 7:15 EDT, the State project engineer (PE) reported that his project trailer had been broken into and a portable nuclear gauge (serial number 062051) was stolen. The equipment was kept stored, with a lock on the outside of the trailer and then locked inside the trailer. The gauge was stored locked in its carrying case.

The gauge model number is Troxler 3440. The gauge contains an 8 mCi Cs-137 source and 40 mCi Am-241/Be source.

Prince George's County Police Department was notified.

* * * UPDATE AT 1507 EDT ON 7/5/17 FROM ALAN JACOBSON TO MARK ABRAMOVITZ * * *

The following report was received via e-mail:

"The Maryland Department of the Environment (MDE) has reported that the portable nuclear gauge stolen on June 28, 2017 from a Maryland Department of Transportation, State Highway Administration (SHA) Project has been recovered. The gauge was apparently found abandoned on a residential property in District Heights, Maryland and recovered by Prince Georges County Police on July 4, 2017 with assistance from the Prince Georges County Fire/EMS Department's HAZMAT Division. The gauge was not damaged. Inspectors from the MDE's Air and Radiation Administration inspected the gauge, confirmed the device was not damaged and it was returned to the SHA Radiation Safety Officer on July 5, 2017."

Notified the R1DO (Ferdas), ILTAB (Tucker), IRD (Grant), and NMSS Resources (via e-mail).

THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf


Agreement State
Event Number: 52832
Rep Org: NJ RAD PROT AND REL PREVENTION PGM
Licensee: UNKNOWN
Region: 1
City: JERSEY CITY   State: NJ
County:
License #:
Agreement: Y
Docket:
NRC Notified By: JENNY GOODMAN
HQ OPS Officer: STEVE SANDIN
Notification Date: 06/28/2017
Notification Time: 17:03 [ET]
Event Date: 06/28/2017
Event Time: 00:00 [EDT]
Last Update Date: 06/28/2017
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
RAY POWELL (R1DO)
NMSS_EVENTS_NOTIFICA (EMAI)
Event Text
AGREEMENT STATE REPORT - ORPHANED Cs-137 SOURCE RECOVERED

The following information was received from the State of New Jersey via email:

"Received a preliminary report today that a metal recycling center (Sims Metal Management) has isolated a Cs-137 source estimated to be about 30 mCi. Exposure readings on contact are 5 R/hr. Source is isolated and secure. The owner of Sims Metal Management contacted Ecology Services who arrived today, identified the nuclide, took the contact readings, conducted wipe tests and will package it and properly and dispose of it in the near future. Ecology Services received reciprocity from NJ for this work. There are no reported markings on the source. DEP [NJ Department of Environmental Protection] personnel will investigate further. More to follow."

THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf


Non-Agreement State
Event Number: 52849
Rep Org: ACUREN INSPECTION
Licensee: ACUREN INSPECTION
Region: 1
City: MORGANTOWN   State: WV
County:
License #: 22-27593-01
Agreement: N
Docket:
NRC Notified By: CHRIS DIXON
HQ OPS Officer: DONG HWA PARK
Notification Date: 07/12/2017
Notification Time: 12:08 [ET]
Event Date: 06/28/2017
Event Time: 17:30 [EDT]
Last Update Date: 07/12/2017
Emergency Class: NON EMERGENCY
10 CFR Section:
30.50(b)(2) - SAFETY EQUIPMENT FAILURE
Person (Organization):
ANTHONY DIMITRIADIS (R1DO)
HIRONORI PETERSON (R3DO)
NMSS_EVENTS_NOTIFICA (EMAI)
Event Text
STUCK RADIOGRAPHY CAMERA SOURCE

"On June 28, 2017, at approximately 1725 EDT, a RT [Radiographic Testing] crew was performing radiography in Morgantown, WV. After completing a weld, they proceeded to move the exposure device to the next location. Due to the terrain and trench conditions, the crew was utilizing a 7 foot guide tube with a 7 foot extension tube with the exposure device on the top side of the trench.

"While exposing the source, the trench below the exposure device shifted causing the exposure device to barrel roll into the trench. The radiographer attempted to retract the source, but was unsuccessful. He then adjusted his boundaries and notified the RSO [Radiation Safety Officer] and Operations Manager [OM] of the situation.

"The RSO proceeded to the Akron, OH lab to gather the retrieval equipment while the OM discussed the situation with the technician over the phone. Multiple photos of the scene were sent to the OM, at which time, it was determined that the guide tube had most likely been damaged during the fall. Within 15 minutes of the initial notification, both the RSO and OM were on their way.

"Once in route to the job site, the OM notified the Assistant Director of Radiation Safety of the situation. He then contacted another RSO to assist in the retrieval.

"At approximately 2130 EDT, the retrieval team arrived on site and continued to assess the situation. The exposure device was at the bottom of a trench, on its side. The source was in an unshielded position. The team believed that the source was just outside of the exposure device due to readings that were taken with the Teletector.

"With multiple attempts of pulling the cranks, the team was eventually able to position the source into the 4 HVL [Half-Value Layer] collimator that was still strapped to the pipe. At this point, the team was able to get a better view of the front of the camera and confirmed that the extension tube had been crimped right at the connection to the bayonet. The exposure device was then pulled backwards by the cranks in an attempt to straighten the tubes. When challenging the cranks, the team confirmed that the source would not be able to be retracted by normal means.

"The team then planned to move the exposure device back to an area of the trench that gave them better access to the damaged tube. They noted that the bungie cord holding the collimator to the pipe was behind the set screw that holds it to the guide tube stop. Knowing that they did not want to lose the 4 HVL of shielding provided by the collimator, they decided that the bungie would need to be removed first.

"With the use of remote tongs and an extendable hook, the collimator was freed from the bungie. At this time, the team proceeded to pull the exposure device back approximately 10 feet to an area with adequate lighting and room to continue with the retrieval process. As the device was being pulled backwards, the guide tube remained over the pipe. The extendable hook was then used to move the remainder of the guide tube and collimator to the camera side of the pipe with the collimator pointing down into the ground.

"With the dose rates at ALARA, the team proceeded with lead shot bags. At first, the bags were walked by rope with one person on either side of the trench. Once the dose rates were lowered even further, the team applied several more until the dose rate at the front of the exposure device was less than 5 mR/hr. The team then approached the exposure device with tools in hand. The tube was unable to be uncrimped completely with the protective coating on the tube. The damaged area was then stripped and uncrimped to the best of the team's ability. Once complete, the area was cleared and the source was retracted back into its shielded position inside of the exposure device. Once the confirmatory surveys were made, [Assistant Director of Radiation Safety] was notified of the successful retrieval."

The three individuals involved in the source retrieval received 13, 5 and 4 mRem.