Skip to main content

Event Notification Report for May 14, 2017

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
05/13/2017 - 05/14/2017

EVENT NUMBERS
527515275252753

Power Reactor
Event Number: 52751
Facility: INDIAN POINT
Region: 1     State: NY
Unit: [] [3] []
RX Type: [2] W-4-LP,[3] W-4-LP
NRC Notified By: MICHAEL McCARTHY
HQ OPS Officer: DONALD NORWOOD
Notification Date: 05/14/2017
Notification Time: 15:32 [ET]
Event Date: 05/14/2017
Event Time: 09:30 [EDT]
Last Update Date: 05/14/2017
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
DON JACKSON (R1DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
3 N N 0 Hot Shutdown 0 Hot Shutdown
Event Text
SINGLE FLOW BARRIER ACCESS POINT FOUND UNBOLTED

"On May 14, 2017, with the Unit in Mode 4, it was identified that a single flow barrier access point (Gate C) to the 46 ft. elevation of Containment was unbolted for access to the inner crane wall to perform surveillance testing. This single flow barrier access point is required to be bolted closed to ensure the Emergency Core Cooling System (ECCS) operability basis which requires the sump barrier system to be operable in Modes 1- 4. The sump barrier system is required to prevent the transport of debris to the recirculation and containment sumps. This event is a safety system functional failure as the condition could have prevented adequate post-accident core cooling due to Design Basis Accident debris blockage of the recirculation and/or the containment sump and is reportable under 10 CFR 50.72(b)(3)(v)(D)."

The licensee notified the NRC Resident Inspector and the New York Public Service Commission.


Power Reactor
Event Number: 52752
Facility: CLINTON
Region: 3     State: IL
Unit: [1] [] []
RX Type: [1] GE-6
NRC Notified By: MARK MAYER
HQ OPS Officer: VINCE KLCO
Notification Date: 05/14/2017
Notification Time: 16:09 [ET]
Event Date: 05/14/2017
Event Time: 07:30 [CDT]
Last Update Date: 05/14/2017
Emergency Class: NON EMERGENCY
10 CFR Section:
26.719 - FITNESS FOR DUTY
Person (Organization):
DAVID HILLS (R3DO)
FFD GROUP (EMAI)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Refueling 0 Refueling
Event Text
FITNESS FOR DUTY

"At 0730 [CDT] on 5/14/2017, a visitor was working in the Protected Area (PA) on the turbine building roof and discovered a blue 12 ounce can of beer in their cooler. This was discovered when the visitor was removing items from their cooler into a larger community cooler. The visitor immediately notified their escort of the prohibited item. The escort then notified Security of the event. Security took possession of the item and the individual was escorted offsite. The individual stated when they packed their cooler at home they thought they had picked up a blue can of soda and did not notice it was a blue can of beer. This event is being reported per 10CFR26.719(b)."

The licensee notified the NRC Resident Inspector.


Power Reactor
Event Number: 52753
Facility: WATERFORD
Region: 4     State: LA
Unit: [3] [] []
RX Type: [3] CE
NRC Notified By: SCOTT MEIKLEJHON
HQ OPS Officer: VINCE KLCO
Notification Date: 05/14/2017
Notification Time: 21:27 [ET]
Event Date: 05/14/2017
Event Time: 18:23 [CDT]
Last Update Date: 05/14/2017
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
JOHN KRAMER (R4DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
3 N N 0 Refueling 0 Refueling
Event Text
FIRE IN ADMINISTRATIVE BUILDING RESULTS IN LOCAL FIRE DEPARTMENT NOTIFICATION

"On May 14, 2017 at time 1823 [CDT], Waterford 3 Steam Electric Station notified St. Charles Parish Emergency Services via 911 of a fire in the Generation Support Building (GSB), the Hahnville, Luling and Killona Fire Departments were dispatched. The GSB is an Administrative and Engineering Building outside the Protected Area and on the Owner Controlled Area. The fire was reported out at 1841. No personnel were injured due to the fire. The fire appeared to be from an external building exhaust fan. There was no internal or structural damage to the building. There was no radiological release. No Safety Related Systems were required to function."

The licensee notified the NRC Resident Inspector.