Skip to main content

Event Notification Report for January 22, 2017

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
01/21/2017 - 01/22/2017

EVENT NUMBERS
5250652503

Agreement State
Event Number: 52506
Rep Org: TEXAS DEPT OF STATE HEALTH SERVICES
Licensee: URI, INC.
Region: 4
City: KINGSVILLE   State: TX
County: KLEBERG
License #: R03653
Agreement: Y
Docket:
NRC Notified By: M ABBASZADEH
HQ OPS Officer: JOHN SHOEMAKER
Notification Date: 01/23/2017
Notification Time: 12:27 [ET]
Event Date: 01/22/2017
Event Time: 00:00 [CST]
Last Update Date: 01/23/2017
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
JESSE ROLLINS (R4DO)
NMSS_EVENTS_NOTIFIC (EMAI)
Event Text
AGREEMENT STATE REPORT - FIRE AT A URANIUM RECOVERY FACILITY

The following report was received from the State of Texas via email:

"On Sunday, January 22, 2017, at 1041 [CST], [the Texas Commission on Environmental Quality] CID [Critical Infrastructure Division] received a call from URI's Radiation Safety Officer [RSO], for the Kingsville Dome facility, that a fire occurred on the west side of well field 17 in Production Area 3, on Sunday morning, January 22, 2017. [The RSO] stated the cause of the fire appeared to be a cigarette butt. A URI operator working at the site noticed the fire. When the operator arrived at the fire location, he noticed that the fire department (FD) was already putting out the fire. At the time of the call, according to [the RSO], the fire was under control and the FD was making sure to put out the hot spots. At the time of the fire, the well field was on a shutdown status and there were no other activities at the well field. The preliminary findings were damage to some of the well field fences and wells in the well field."

The extent of damage is still being evaluated and there are no reports of contamination or exposures, outside of the facility, at this time.

The URI, Inc., Kingsville Dome is an In-Situ Uranium Recovery facility in Texas.

Texas Report Number: None assigned at this time.


Power Reactor
Event Number: 52503
Facility: FITZPATRICK
Region: 1     State: NY
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: THOMAS YURKON
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 01/22/2017
Notification Time: 16:19 [ET]
Event Date: 01/22/2017
Event Time: 14:00 [EST]
Last Update Date: 01/22/2017
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(ii)(A) - DEGRADED CONDITION
Person (Organization):
SILAS KENNEDY (R1DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Refueling 0 Refueling
Event Text
WELD DEFECT FOUND DURING A SHUTDOWN INSPECTION

"Information from a Manual Phased Array UT (Ultrasonic Testing) examination of the 'A' RHR LPCI [Residual Heat Removal Low Pressure Coolant Injection] Injection Loop indicates an axially oriented indication 0.95 inch in length and 0.81 inch through wall. This is on weld number 24-10-130 (T to Valve dissimilar metal weld).

"This event is being reported as a degraded condition pursuant to 10CFR50.72(b)(3)(ii)(A) based on the fact that the indications result in a defect in the primary coolant system which cannot be found acceptable under ASME Section XI.

"The licensee informed the NRC Resident Inspector."

The weld is located where the RHR piping taps into the reactor vessel. The wall thickness at this location is 1.15 inches.