Skip to main content

Event Notification Report for January 16, 2017

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
01/15/2017 - 01/16/2017

EVENT NUMBERS
524915249252493

Fuel Cycle Facility
Event Number: 52491
Facility: BWX TECHNOLOGIES, INC.
Region: 2     State: VA
Unit: [] [] []
RX Type: URANIUM FUEL FABRICATION
NRC Notified By: DAVE SPANGLOR
HQ OPS Officer: STEVEN VITTO
Notification Date: 01/16/2017
Notification Time: 15:55 [ET]
Event Date: 01/16/2017
Event Time: 09:15 [EST]
Last Update Date: 01/16/2017
Emergency Class: NON EMERGENCY
10 CFR Section:
26.719 - FITNESS FOR DUTY
Person (Organization):
SCOTT SHAEFFER (R2DO)
ANGELA MCINTOSH (NMSS)
NMSS_EVENTS_NOTIFIC (EMAI)
FFD GROUP (EMAI)
Event Text
FITNESS-FOR- DUTY
A non-licensed employee supervisor had a confirmed positive for alcohol during a random fitness-for-duty test. The employee's access to the site has been terminated.

The Licensee has notified the NRC Resident Inspector.


Power Reactor
Event Number: 52492
Facility: PILGRIM
Region: 1     State: MA
Unit: [1] [] []
RX Type: [1] GE-3
NRC Notified By: MICHAEL MCDONNELL
HQ OPS Officer: STEVEN VITTO
Notification Date: 01/16/2017
Notification Time: 16:39 [ET]
Event Date: 01/16/2017
Event Time: 11:55 [EST]
Last Update Date: 01/16/2017
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(C) - POT UNCNTRL RAD REL 50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
ANTHONY DIMITRIADIS (R1DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
FAILURE OF REACTOR BUILDING ISOLATION DAMPERS TO ISOLATE

"On January 16, 2017, with the reactor at 100 percent and the mode switch in RUN, Pilgrim Station was performing preventative maintenance of secondary containment isolation dampers when dampers AO-N-82 and AO-N-83, refueling floor supply isolation dampers, failed to fully close when the control switches were taken to close.

"This 8-hour non-emergency notification is being made in accordance with 10 CFR 50.72(b)(3)(v), Any event or condition that at the time discovery could have prevented the fulfillment of the safety function of structures or systems that are needed to: (C) Control the release of radioactive material; or (D) Mitigate the consequences of an accident.

"The reactor building isolation dampers were cleaned and lubricated and post-work tested and timed in accordance with station procedures to verify that they had satisfactory closing times. Pilgrim Nuclear Power Station has returned the dampers to Operable status.

"The licensee will notify the Commonwealth of Massachusetts."

The licensee has notified the NRC Resident Inspector.


Agreement State
Event Number: 52493
Rep Org: TEXAS DEPT OF STATE HEALTH SERVICES
Licensee: IRISNDT INC
Region: 4
City: HOUSTON   State: TX
County:
License #: 06435
Agreement: Y
Docket:
NRC Notified By: IRENE CASARES
HQ OPS Officer: DONALD NORWOOD
Notification Date: 01/17/2017
Notification Time: 10:36 [ET]
Event Date: 01/16/2017
Event Time: 00:00 [CST]
Last Update Date: 01/17/2017
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
GREG WERNER (R4DO)
NMSS_EVENTS_NOTIFIC (EMAI)
Event Text
AGREEMENT STATE REPORT - RADIOGRAPHY DEVICE DAMAGED

The following information was received via E-mail:

"On January 17, 2017, the Agency [Texas Department of State Health Services] was notified by the licensee that on January 16, 2017 at 0200 CST a source retrieval had been completed. The source was Ir-192, 94 curies, serial number YA0408, used in a Spec 150 radiography device. The licensee reported that piping being imaged fell from the holding stand onto the guide tube crushing it and causing the source to become stuck and non-retractable. The radiographers called the radiation safety officer (RSO) who after several unsuccessful attempts to open the guide tube had to cut the source from the cable and placed it into the device with long reach tongs. No member of the public was exposed and the RSO maintained his exposure to not exceed regulatory limits. The licensee stated the device was taken out of service and will supply a detailed report of the incident. Additional information will be provided as it is received in accordance with SA300."

Texas Incident #: I-9457