Power Reactor
Event Number: 52363
Facility: COMANCHE PEAK
Region: 4     State: TX
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: DANNY BRADFORD
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 11/13/2016
Notification Time: 17:39 [ET]
Event Date: 11/13/2016
Event Time: 10:12 [CST]
Last Update Date: 11/13/2016
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
VIVIAN CAMPBELL (R4DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
ONE MAIN STEAM LINE RADIATION MONITOR FAILED

"At 1012 [CST], Unit 1 Main Steam Line 1-01 Radiation Monitor (1-RE-2325) failed high. With this radiation monitor non-functional, all of the emergency action levels for a steam generator tube rupture in steam generator 1-01 could neither be evaluated nor monitored. This unplanned condition is reportable as a loss of assessment capability per 10 CFR 50.72(b)(3)(xiii).

"Comanche Peak Nuclear Power Plant (CPNPP) has assurance of steam generator integrity and fuel cladding integrity and there is a negligible safety significance to the current condition from a public health and safety perspective. Additionally, compensatory measures are in place to assure adequate monitoring capability is available to implement the CPNPP emergency plan in the unlikely event of challenges to the steam generator or fuel cladding.

"Until this radiation monitor can be restored, Operations has implemented compensatory measures to monitor the main steamline 1-01 N-16 [Nitrogen-16] radiation monitor for early signs of a steam generator tube leak/rupture and pre-brief radiation protection technicians on taking local readings with a Geiger-Muller tube on Main Steam Line 1-01 and reporting the reading to the Control Room. Corrective actions are being pursued to restore 1-RE-2325 to functional status.

"The NRC Resident Inspector has been notified."

Radiation monitor 1-RE-2325 is not in the plant technical specifications but is important to safety and the Emergency Plan.