Skip to main content

Event Notification Report for October 06, 2016

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
10/05/2016 - 10/06/2016

EVENT NUMBERS
5228652348

Agreement State
Event Number: 52286
Rep Org: VIRGINIA RAD MATERIALS PROGRAM
Licensee: GLOBAL GEOTECHNICAL CONSULTANTS
Region: 1
City: FAIRFAX   State: VA
County:
License #: 153-619-1
Agreement: Y
Docket:
NRC Notified By: CHARLES COLEMAN
HQ OPS Officer: DONALD NORWOOD
Notification Date: 10/07/2016
Notification Time: 13:09 [ET]
Event Date: 10/06/2016
Event Time: 00:00 [EDT]
Last Update Date: 10/07/2016
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
JON LILLIENDAHL (R1DO)
NMSS_EVENTS_NOTIFIC (EMAI)
Event Text
AGREEMENT STATE REPORT - DAMAGED MOISTURE/DENSITY GAUGE

The following information was received via facsimile:

"On October 6, 2016, at approximately 0200 EDT, a loader backed over the licensee's portable gauge during work in Fairfax County, Virginia. The gauge was a Troxler Model 3400, s/n 31366, with an 8 millicurie cesium-137 source, s/n 750-6052, and a 40 millicurie americium-241:Be source, s/n 47-28023. The operator secured the gauge and cordoned the accident area. Radiation surveys by the licensee's Radiation Safety Officer confirmed the sources were in their shielded positions and that no contamination resulted from the accident. The damaged gauge has been shipped to a licensed service provider for repair."

Virginia Event Report ID No.: VA-16-014


Agreement State
Event Number: 52348
Rep Org: ILLINOIS EMERGENCY MGMT. AGENCY
Licensee: CLARK DIETRICH BLDG SYSTEMS
Region: 3
City: ROCHELLE   State: IL
County:
License #: 9223802
Agreement: Y
Docket:
NRC Notified By: DAREN PERRERO
HQ OPS Officer: VINCE KLCO
Notification Date: 11/07/2016
Notification Time: 12:28 [ET]
Event Date: 10/06/2016
Event Time: 00:00 [CDT]
Last Update Date: 11/07/2016
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
MARK JEFFERS (R3DO)
NMSS_EVENTS_NOTIFICA (EMAI)
Event Text
AGREEMENT STATE REPORT - SHUTTER FAILED TO OPERATE AS DESIGNED

The following information was received by email:

"On November 2, [2016], the registrant's representative reported [to the State of Illinois] that a generally licensed gauge under their control had failed to operate as designed. A Gamma Instruments model GR100 device exhibited signs of the shutter not closing properly. A contractor was notified and repairs affected. The gauge was subsequently returned to service with no additional engineering issues noted. Procedures at the plant were modified such that the area around the gauge is now cleaned following each shift."

The fixed gauge serial number was 930706, and the sealed source was 37 GBq of Am-241.

Illinois Event: IL 16010