Skip to main content

Event Notification Report for May 24, 2016

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
05/23/2016 - 05/24/2016

EVENT NUMBERS
519545195551970

Power Reactor
Event Number: 51954
Facility: SUMMER
Region: 2     State: SC
Unit: [1] [] []
RX Type: [1] W-3-LP,[2] W-AP1000,[3] W-AP1000
NRC Notified By: MICHAEL MOORE
HQ OPS Officer: BETHANY CECERE
Notification Date: 05/24/2016
Notification Time: 15:28 [ET]
Event Date: 05/24/2016
Event Time: 12:50 [EDT]
Last Update Date: 05/24/2016
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
EUGENE GUTHRIE (R2DO)
SHANA HELTON (NRR)
WILLIAM GOTT (IRD)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
OFFSITE NOTIFICATION DUE TO ONSITE FATALITY NOT RELATED TO WORK

"At approximately 1250 [EDT], a contract employee was found unresponsive in [their] personal vehicle located in the parking lot outside of the owner controlled area. The Fairfield County Coroner arrived on-site and declared the individual deceased at 1345. The fatality was due to an apparent personal medical issue and not work related."

The licensee has notified the NRC Resident Inspector.

The licensee has notified State of South Carolina Department of Labor - OSHA.


!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 51955
Facility: COMANCHE PEAK
Region: 4     State: TX
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: ANTHONY PATE
HQ OPS Officer: JEFF HERRERA
Notification Date: 05/24/2016
Notification Time: 17:48 [ET]
Event Date: 05/24/2016
Event Time: 10:22 [CDT]
Last Update Date: 06/02/2016
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
GREG WERNER (R4DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Cold Shutdown 0 Cold Shutdown
2 N Y 100 Power Operation 100 Power Operation
Event Text
UNPLANNED LOSS OF EMERGENCY ASSESSMENT CAPABILITY

"CPNPP [Comanche Peak Nuclear Power Plant] experienced an unplanned loss of the seismic monitoring instrument on May 24, 2016 at 1022 [CDT]. The unplanned loss of the seismic monitor resulted in a loss of assessment capability for the HA1.1 (seismic event greater than operating basis earthquake) Alert emergency classification. The seismic monitor was restored to service on May 24, 2016 at 1043.

"This loss of assessment capability is reportable to the NRC within 8 hours of discovery in accordance with 10 CFR 50.72(b)(3)(xiii)."

The NRC Resident Inspector has been notified.

* * * UPDATE ON 6/2/16 AT 1630 EDT FROM ANTHONY PATE TO DONG PARK * * *

"On May 24, 2016 at 1748 [EDT], Comanche Peak reported an unplanned loss of emergency assessment capability per 10 CFR 50.72(b)(3)(xiii) [EN# 51955]. Specifically, Comanche Peak reported an unplanned loss of the seismic monitoring instrument. The unplanned loss of the seismic monitor would have resulted in a loss of assessment capability for the HA 1.1 (seismic event greater than operating basis earthquake) Alert emergency classification. The seismic monitor was restored to service on May 24, 2016 at 1043 [CDT].

"The engineering review determined that the alarms displayed on the seismic monitoring screen provides Operations awareness of the system status. Signals were still being received from the sensor and if there was an OBE [Operating Basis Earthquake] during the time the alarms were in, it would have displayed on the monitoring screen and on the Main Control Board by providing an OBE Exceedance alarm, maintaining emergency assessment capability. Therefore, Comanche Peak requests that the May 24, 2016, 10 CFR 50.72(b)(3)(xiii) reportable event for Units 1 & 2 be retracted."

The licensee will notify the NRC Resident Inspector.

Notified R4DO (Deese).


Agreement State
Event Number: 51970
Rep Org: NEW YORK STATE DEPT. OF HEALTH
Licensee: NOT PROVIDED
Region: 1
City:   State: NY
County:
License #:
Agreement: Y
Docket:
NRC Notified By: JANAKI KRISHNAMOORTHY
HQ OPS Officer: JEFF HERRERA
Notification Date: 06/01/2016
Notification Time: 15:17 [ET]
Event Date: 05/24/2016
Event Time: 00:00 [EDT]
Last Update Date: 06/01/2016
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
DAN SCHROEDER (R1DO)
NMSS_EVENTS_NOTIFIC (EMAI)
Event Text
AGREEMENT STATE REPORT - MEDICAL UNDERDOSE TO THE LEFT LOBE OF LIVER

The following report was received from the New York State Department of Health, Bureau of Environmental Radiation Protection via facsimile:

"Radiation safety staff from a hospital called on 5/24/2016 to report a medical event that meets the reportability criterion on the borderline. 79.5 percent of intended dose is believed to have been delivered to the left lobe of the liver of a patient receiving Y90 treatment. The patient had received treatment to the right lobe a month ago. The left lobe was smaller with small vessels. The waste measured after the procedure showed that only about 79 .5 percent had been delivered. The licensee usually is able to administer 95 percent of intended dose in this procedure. We were informed that since the amount retained in the device is about the same, smaller doses tend to show a greater percent in retained in the device. They will send a report within 7 days."

NYS NRC Event Report ID No.: NYDOH-16-02
NY State Incident No.: 1146

A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.