Skip to main content

Event Notification Report for April 27, 2016

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
04/26/2016 - 04/27/2016

EVENT NUMBERS
51893518875188851889

Agreement State
Event Number: 51893
Rep Org: ARIZONA RADIATION REGULATORY AGENCY
Licensee: MAYO CLINIC ARIZONA
Region: 4
City: PHOENIX   State: AZ
County:
License #: AZ 07-448
Agreement: Y
Docket:
NRC Notified By: BRIAN GORETZKI
HQ OPS Officer: DANIEL MILLS
Notification Date: 04/30/2016
Notification Time: 13:53 [ET]
Event Date: 04/27/2016
Event Time: 00:00 [MST]
Last Update Date: 04/30/2016
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
JEREMY GROOM (R4DO)
NMSS_EVENTS_NOTIFIC (EMAI)
Event Text
AGREEMENT STATE REPORT - IMPLANTED IODINE 125 SEED NOT ACCOUNTED FOR

The following was received from Arizona via email:

"On April 27th, the licensee [Mayo Clinic Arizona] discovered that one (1) I-125 seed was missing with an approximate activity of 0.3 millicuries. The breast tissue from a patient was analyzed by the licensees' surgical staff on April 26th and one seed was removed and then brought down to the nuclear medicine department on the morning of the 27th. The nuclear medicine staff quickly realized that there should have been two seeds, since two seeds were initially implanted. The licensee's radiation safety staff surveyed both the hospital surgical path area as well as the pathology/histology area and no source was discovered.

"The investigation into this event is ongoing.

"The U.S. NRC and Arizona Governor's office are being notified of this event."

Arizona Incident # 16-007

A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.


Power Reactor
Event Number: 51887
Facility: COOPER
Region: 4     State: NE
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: CURTIS MARTIN
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 04/27/2016
Notification Time: 12:25 [ET]
Event Date: 04/27/2016
Event Time: 08:23 [CDT]
Last Update Date: 04/27/2016
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION 50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
JEREMY GROOM (R4DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
LOSS OF TONE ALERT RADIO SYSTEM TOWER

"At 0823 CDT on 4/27/2016, Cooper Nuclear Station was notified by the National Weather Service that the Shubert radio transmission tower was not functioning. This affects the tone alert radios used to notify the public in the event of an emergency condition. This is considered to be a major loss of the public prompt notification system capability and is reportable under 10CFR50.72(b)(3)(xiii).

"Nemaha, Richardson and Atchison county authorities within the 10 mile EPZ [Emergency Planning Zone] were notified of the condition and the effect on the tone alert radios and will utilize local route notification (backup notification method) making this condition reportable under 10CFR50.72(b)(2)(xi) for notification of other government agencies.

"Estimated return to service time is unknown. The cause of the failure is a loss of communication with the tower.

"The NRC Senior Resident Inspector has been notified of this condition."


Non-Agreement State
Event Number: 51888
Rep Org: SPECTRUM HEALTH
Licensee: SPECTRUM HEALTH
Region: 3
City: GRAND RAPIDS   State: MI
County:
License #: 21-00243-06
Agreement: N
Docket:
NRC Notified By: EVAN BOOTE
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 04/27/2016
Notification Time: 17:09 [ET]
Event Date: 04/27/2016
Event Time: 14:05 [EDT]
Last Update Date: 04/27/2016
Emergency Class: NON EMERGENCY
10 CFR Section:
35.3045(a)(2) - DOSE > SPECIFIED EFF LIMITS
Person (Organization):
ANN MARIE STONE (R3DO)
NMSS_EVENTS_NOTIFICA (EMAI)
Event Text
MEDICAL EVENT - DOSE GIVEN TO INCORRECT SEGMENT OF THE LIVER

During a Y-90 TheraSphere treatment (hepatocellular carcinoma) to the right lobe of the liver segments 5, 6, 7, and 8 (estimated volume of 1290 ml), the catheter moved and the dose was actually given to medial segment 4 (estimated volume of 330 ml). The prescribed dose was 120 Gy (3.3 GBq) and the delivered dose was approximately 118.5 Gy as determined by bremmstrahlung imaging. Segment 4 was previously treated and there was some residual cancer at this location. This dose is not expected to have detrimental effects on the patient.

It is anticipated that segments 5,6,7,8 will be treated at some future time.

The patient has been notified and the prescribing physician will be notified.

A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.


Power Reactor
Event Number: 51889
Facility: MILLSTONE
Region: 1     State: CT
Unit: [] [2] []
RX Type: [1] GE-3,[2] CE,[3] W-4-LP
NRC Notified By: MICHAEL GAGNON
HQ OPS Officer: JEFF HERRERA
Notification Date: 04/28/2016
Notification Time: 00:15 [ET]
Event Date: 04/27/2016
Event Time: 20:07 [EDT]
Last Update Date: 04/28/2016
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(B) - POT RHR INOP 50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
JAMES DWYER (R1DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 100 Power Operation
Event Text
HIGH ENERGY LINE BREAK DOOR DISCOVERED OPEN

"On April 27, 2016 at 20:07 [EDT], a high energy line break (HELB) door between the turbine driven auxiliary feedwater pump and the motor driven auxiliary feedwater pump rooms was discovered open and unattended. In the event of a HELB, this condition could have rendered both trains of auxiliary feedwater inoperable. The boundary was not operable for approximately 1 hour. Upon discovery, the door was closed restoring the boundary.

"This event is being reported pursuant to 10 CFR 50.72(b)(3)(v) as any event or condition that alone could have prevented the fulfillment of the safety function of structures or systems that are needed to: (B) Remove residual heat; and (D) Mitigate the consequences of an accident.

"The NRC Senior Resident Inspector has been notified."

The Licensee notified the Connecticut DEEP and Waterford Dispatch.