AGREEMENT STATE REPORT - RADIOGRAPHY SOURCE DISCONNECT

The following information was received from the State of Texas via email:

"On April 16, 2014, the Agency [Texas Department of State Health Services] received notice that on April 15, 2014, a radiography source disconnect had occurred at a temporary field site in or near Martinsville, Texas at approximately 4:45 PM. The camera was a QSA 880D with a 22 curie iridium-192 source. The source was retrieved. No exposure to the public resulted from this event. The cause of failure is unknown at this time, but a crank malfunction is suspected. Additional information will be supplied as it is received in accordance with SA-300."

Texas Incident #: I-9184


Power Reactor
Event Number: 50038
Facility: FORT CALHOUN
Region: 4     State: NE
Unit: [1] [] []
RX Type: (1) CE
NRC Notified By: MICHAEL PEAK
HQ OPS Officer: CHARLES TEAL
Notification Date: 04/15/2014
Notification Time: 19:16 [ET]
Event Date: 04/15/2014
Event Time: 15:15 [CDT]
Last Update Date: 04/15/2014
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(i) - PLANT S/D REQD BY TS
Person (Organization):
VINCENT GADDY (R4DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
TECHNICAL SPECIFICATION REQUIRED SHUTDOWN DUE TO FAILURE OF CONTROL ROOM AIR CONDITIONING

"At 1505 CDT the 'A' control room air conditioner (VA-46A) trouble alarm annunciated in the control room. The unit was confirmed to be not functioning properly and was declared inoperable at time 1515 [CDT]. The 'B' control room air conditioner (VA-46B) was previously declared inoperable due to maintenance. With both control room air conditioners inoperable the plant entered technical specification 2.0.1, a 6 hour shutdown action statement. Repairs to the 'B' had been previously planned and are in progress to allow the unit to be returned to service as soon as possible. Troubleshooting and subsequent repairs to the 'A' unit are in progress. At 1812 [CDT], the station commenced a shutdown to comply with the required action statement."

The NRC Resident Inspector has been informed.

* * * UPDATE FROM ORTIZ TO KLCO ON 4/15/14 AT 2237 EDT * * *

"At time 2050 [CDT], VA-46A was declared operable based on installation of an emergency temporary modification. TS 2.0.1 has been exited. Shutdown has been secured and FCS is stable at a nominal 33% power."

The licensee notified the NRC Resident Inspector.

Notified the R4DO (Gaddy).