Power Reactor
Event Number: 49531
Facility: SUSQUEHANNA
Region: 1     State: PA
Unit: [1] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: MARTIN LICHTNER
HQ OPS Officer: JOHN SHOEMAKER
Notification Date: 11/13/2013
Notification Time: 09:53 [ET]
Event Date: 11/13/2013
Event Time: 02:26 [EST]
Last Update Date: 01/10/2014
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(C) - POT UNCNTRL RAD REL
Person (Organization):
J LILLIENDAHL (R1DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 99 Power Operation 99 Power Operation
2 N Y 100 Power Operation 100 Power Operation
Event Text
SECONDARY CONTAINMENT ZONE II DIFFERENTIAL PRESSURE LOST DURING RECOVERY FROM VENTILATION DRAWDOWN TEST

"On November 13, 2013 at 0226 [EST], Secondary Containment Zone II (Unit 2 Reactor Building) differential pressure was lost during restoration of a ventilation drawdown test. During restoration Unit 2 'A' Train Reactor Building Ventilation fans tripped. The 'B' Train fans were placed in service and secondary containment was restored. Zone I (Unit 1 Reactor Building) and III (Common Refuel Floor Area) ventilation remained in service and stable.

"Zone II differential pressure recovered within a few minutes and was verified to be stable. LCO 3.6.4.1 was exited for both units at 0257 [EST]. Tech Spec Secondary Containment Operability requires a negative pressure of at least 0.25 inches water gauge.

"There have been no further perturbations in differential pressure and secondary containment remains operable.

"This event is being reported under 10 CFR 50.72(b)(3)(v)(c) and per the guidance of NUREG 1022 Rev 3 section 3.2.7 as a loss of a Safety Function. There is no redundant Susquehanna Secondary Containment System."

The cause of the Unit 2 "A" Train Reactor Building ventilation fans tripping is still under investigation.

The licensee has notified the NRC Resident Inspector.

* * * RETRACTION ON 1/10/14 AT 1657 EST FROM DOUG LAMARCA TO NESTOR MAKRIS * * *

"NUREG-1022, Revision 3 states, ' reports are not required when systems are declared inoperable as part of a planned evolution for maintenance or surveillance testing when done in accordance with an approved procedure and the plant's TS (unless a condition is discovered that would have resulted in the system being declared inoperable).'

"The event reported in this event notification occurred during a pre-planned evolution for surveillance testing that was done in accordance with an approved procedure and the Susquehanna Technical Specifications. The loss of differential pressure occurred during restoration from the surveillance test and occurred prior to completing the planned evolution and declaring the system OPERABLE. Specifically, the trip of the fans occurred when restoring the Reactor Building normal ventilation after a Zone 1, 2, and 3 isolation (returning back to normal ventilation from the Standby Gas Treatment System). The secondary containment boundary and standby gas treatment system were unaffected. This event occurred as a result of the testing process and would not have occurred during normal operation of the system. There was no discovered condition that would have resulted in the safety function of the system being declared inoperable under normal, non-testing conditions.

"Based on the above additional information, PPL is retracting this report. Susquehanna was in a planned evolution and did not discover a condition that could have prevented performing a safety function."

The licensee has notified the NRC Resident Inspector. Notified the R1DO (Schmidt).


Agreement State
Event Number: 49532
Rep Org: COLORADO DEPT OF HEALTH
Licensee: MIDWEST INSPECTION DBA DESERT NDT
Region: 4
City: BARNSVILLE   State: CO
County: WELD
License #: CO-RML#902-01
Agreement: Y
Docket:
NRC Notified By: CHERI HALL
HQ OPS Officer: JOHN SHOEMAKER
Notification Date: 11/13/2013
Notification Time: 10:23 [ET]
Event Date: 11/13/2013
Event Time: 00:00 [MST]
Last Update Date: 11/13/2013
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
THOMAS FARNHOLTZ (R4DO)
FSME EVENTS RESOURCE (EMAI)
Event Text
AGREEMENT STATE REPORT - SOURCE DISCONNECT

The following Agreement State Report was received via email:

"On Thursday, November 7, 2013, Midwest Inspection dba [doing business as] Desert NDT experienced a source disconnect [on a INC Radiography Camera]. The RSO was able to retrieve the source into a shielded source exchange container as authorized to do on the license. No over-exposures are reported at this time, and an investigation is underway by [Colorado] Department employees. A full report will follow in the next 30 days."

The camera is an INC radiography camera, Model 32, Serial # 7292. The licensee RSO received 54 mrem while performing a source exchange on the camera.


Power Reactor
Event Number: 49533
Facility: WOLF CREEK
Region: 4     State: KS
Unit: [1] [] []
RX Type: [1] W-4-LP
NRC Notified By: PIERCE C. MOORE
HQ OPS Officer: JOHN SHOEMAKER
Notification Date: 11/13/2013
Notification Time: 11:42 [ET]
Event Date: 11/13/2013
Event Time: 09:24 [CST]
Last Update Date: 11/13/2013
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
THOMAS FARNHOLTZ (R4DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
FUEL OIL LEAK TO THE ENVIRONMENT

"Approximately 10 gallons of fuel oil was spilled from excavation equipment onto the ground inside the owner controlled area. Notifications will be made to the National Response Center and the Kansas Dept. of Health and Environment. Cleanup by on-site personnel is in progress. No fuel oil made contact with any surface water.

"NRC resident inspector has been notified [by the licensee]."


!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Agreement State
Event Number: 50267
Rep Org: PA BUREAU OF RADIATION PROTECTION
Licensee: LEHIGH VALLEY HOSPITAL - HAZLETON
Region: 1
City: HAZLETON   State: PA
County:
License #: PA-0106
Agreement: Y
Docket:
NRC Notified By: DAVID ALLARD
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 07/10/2014
Notification Time: 14:35 [ET]
Event Date: 11/13/2013
Event Time: 00:00 [EDT]
Last Update Date: 07/28/2014
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
ANNE DeFRANCISCO (R1DO)
FSME EVENTS RESOURCE (FSME)
Event Text
AGREEMENT STATE REPORT - BRACHYTHERAPY UNDERDOSE

The following information was received via fax:

"This medical event (ME) was self-identified by the licensee during an audit. A patient who had undergone an iodine-125 (I-125) prostate brachytherapy procedure was reported to have a 'D90' dose of 43% of the written directive. The licensee radiation safety officer and physician are in contact regarding this ME. It is unknown at this time if the patient has been notified.

"The Department [Pennsylvania Department of Environmental Protection] is waiting for the required 15 day written report from the licensee. The Department will then conduct a reactive inspection."

PA Event Number: PA140017

A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.


* * * RETRACTION FROM DAVID ALLARD TO DONALD NORWOOD AT 1641 EDT ON 7/28/2014 * * *

The following information was received via facsimile:

"Through an internal audit, it was initially thought that a patient who had undergone an iodine-125 (I-125) prostrate brachytherapy treatment in November, 2013 was believed to have had a 'D90' dose of only 43% of the written directive. However, based on a re-assessment by the licensee's Chief Medical Physicist, it appears that greater than 80% of the prostate volume received the prescribed dose.

"[The] reported medical event is to be retracted."

Notified R1DO (Dimitriadis) and FSME Events Resource via E-mail.