Fuel Cycle Facility
Event Number: 49341
Facility: GLOBAL NUCLEAR FUEL - AMERICAS
Region: 2     State: NC
Unit: [] [] []
RX Type: URANIUM FUEL FABRICATION
Comments: LEU CONVERSION (UF6 TO UO2)
LEU FABRICATION
LWR COMMERICAL FUEL
NRC Notified By: SCOTT MURRAY
HQ OPS Officer: BILL HUFFMAN
Notification Date: 09/13/2013
Notification Time: 10:55 [ET]
Event Date: 09/13/2013
Event Time: 10:45 [EDT]
Last Update Date: 09/27/2013
Emergency Class: NON EMERGENCY
10 CFR Section:
PART 70 APP A (a)(4) - ALL SAFETY ITEMS UNAVAILABLE
Person (Organization):
SCOTT SHAEFFER (R2DO)
MERAJ RAHIMI (NMSS)
WILLIAM GOTT (IRD)
Event Text
ITEM RELIED ON FOR SAFETY MAY NOT BE RELIABLE

"At about 1045 EDT on 9/13/13, it was discovered that the feed tube level sensor on a press operation is not fail safe upon loss of signal. The sensor is a sole IROFS [Item Relied On For Safety] for a particular sequence. Criticality controls remained in place. Affected equipment has been shut down. No unsafe condition exists. Feed tube level sensor is in place for the sequence to limit mass. At no time was the mass limit exceeded. We are reporting under Part 70, Appendix A, (a)(4) which states that credited IROFS must remain available and reliable. We cannot evaluate reliability in the time required for a 1 hour report. In addition, the affected equipment has been secured. An investigation is underway to determine corrective actions and extent of condition."

The license will notify NRC Region 2.

* * * RETRACTION FROM SCOTT MURRAY TO DANIEL MILLS ON 9/27/2013 AT 1003 EDT * * *

"On 9/13/13, GNF-A conservatively made a 1 hour event notification (EN 49341) due to a discovery that a feed tube level sensor is not fail safe upon loss of signal. After further review, it has been determined that the control remained available, reliable and continued to meet performance requirements. As a result, the event notification is retracted."

The licensee has notified NRC Region 2.

Notified R2DO (Sykes), NMSS EO (Rubenstone), and IRD (Grant).


Agreement State
Event Number: 49348
Rep Org: TEXAS DEPARTMENT OF HEALTH
Licensee: MISTRAS GROUP INC.
Region: 4
City: LA PORTE   State: TX
County:
License #: LO6369
Agreement: Y
Docket:
NRC Notified By: KAREN BLANCHARD
HQ OPS Officer: PETE SNYDER
Notification Date: 09/16/2013
Notification Time: 13:58 [ET]
Event Date: 09/13/2013
Event Time: 00:00 [CDT]
Last Update Date: 09/16/2013
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
RICK DEESE (R4DO)
FSME EVENTS RESOURCE (EMAI)
Event Text
AGREEMENT STATE REPORT - RADIOGRAPHY CAMERA SOURCE FAILS TO RETRACT

"On September 16, 2013, the licensee notified the Agency [Texas Department of Health] that on September 13, 2013, one of its radiography crews had been unable to retract a Iridium-192 source back into a SPEC 150 exposure device at a temporary work site in Tilden, Texas. Following the first exposure of the morning, the source pigtail would not retract fully into the device. An authorized person performed the source retrieval. This individual received 20 millirem and the individual that assisted him received 10 millirem. No member of the public received any exposure as a result of this event.

"The licensee's radiation safety officer inspected the inside of the source guide tube using a tube scope and found that the coil in the source guide tube was pushed out into the inside of the tube where the connector fitting was crimped onto the guide tube. The connector had just been replaced by a local service company. An investigation into this event is ongoing. Information will be provided as it is obtained in accordance with SA-300."

Texas State Report # I-9114