Skip to main content

Event Notification Report for August 05, 2013

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
08/04/2013 - 08/05/2013

EVENT NUMBERS
4924249250492364923849239492444925249320

Agreement State
Event Number: 49242
Rep Org: VIRGINIA RAD MATERIALS PROGRAM
Licensee: ECS MID-ATLANTIC, LLC
Region: 1
City: LEXINGTON   State: VA
County:
License #: VA-770-314-5
Agreement: Y
Docket:
NRC Notified By: MIKE WELLING
HQ OPS Officer: DONG HWA PARK
Notification Date: 08/06/2013
Notification Time: 11:04 [ET]
Event Date: 08/05/2013
Event Time: 00:00 [EDT]
Last Update Date: 08/06/2013
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
JAMES TRAPP (R1DO)
FSME EVETS RESOURCE (EMAI)
Event Text
AGREEMENT STATE REPORT - DAMAGED DENSITY GAUGE

The following information was received from the Commonwealth of Virginia via facsimile:

"On August 5, 2013, an Authorized User (AU) was conducting density testing for asphalt placement for a parking lot using a CPN MC-1-DR. The AU had just performed a density test and set the gauge on the adjacent asphalt approximately 5 feet from the joint for the hot asphalt. The AU stepped to the joint to tell the asphalt roller operator that density values were low. As the AU stepped back, he heard a tandem axle truck backing up. As he stepped to pick up the gauge, he realized the rear tandem axle tire was about to strike the gauge. By the time he pulled the gauge handle, the rear tire rolled over the gauge. He pulled the gauge away from between the rear tandem axle tire and the center axle tire. He then set the gauge down. A survey of the damage gauge was performed by the RSO and the sources were verified to be in their shielded position. The gauge was returned to the shop for shipment to CPN. There was no adverse effect to public health and safety from this event."

VA Event Report ID Number: VA-13-05


Agreement State
Event Number: 49250
Rep Org: TENNESSEE DIV OF RAD HEALTH
Licensee: AEROJET ORDNANCE TENNESSEE
Region: 1
City: JONESBOROUGH   State: TN
County:
License #: S-90009
Agreement: Y
Docket:
NRC Notified By: LAURA TURNER
HQ OPS Officer: BILL HUFFMAN
Notification Date: 08/08/2013
Notification Time: 11:09 [ET]
Event Date: 08/05/2013
Event Time: 10:00 [EDT]
Last Update Date: 08/08/2013
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
JAMES TRAPP (R1DO)
FSME EVENT RESOURCES (E-MA)
Event Text
AGREEMENT STATE REPORT - ELEVATED AIRBORNE URANIUM LEVELS DUE TO EQUIPMENT MALFUNCTION

The following report was received from the State of Tennessee Division of Radiological Health via e-mail:

"Tennessee's Division of Radiological Health was notified on Wednesday August 7, 2013 by the RSO from Aerojet Ordnance Tennessee, regarding the failure of a primary ventilation system. On August 5, 2013 at 10:00 AM, an employee at the Deflash Station observed smoke outside the operation booth while grinding burrs off radiography camera castings. A supervisor was notified and investigation showed the ventilation system was working, but the belt connecting the pump and fan was broken. Operations were suspended and personnel evacuated.

"The belt was replaced on the pumps and the ventilation system was up and operational by 10:30 AM. Event resulted in elevated airborne uranium concentrations. All personnel in the building submitted urinalysis. Workers at the Deflash station were wearing respiratory protection during time of event as part of standard procedures. Area air samplers along with environmental air samplers were pulled and analyzed; initial results identified no concerns of elevated concentrations.

"The State will follow-up and keep NRC informed of the status of our investigation."

Tennessee Report Number:TN-13-134


Power Reactor
Event Number: 49236
Facility: MILLSTONE
Region: 1     State: CT
Unit: [] [2] []
RX Type: [1] GE-3,[2] CE,[3] W-4-LP
NRC Notified By: TODD PERKINS
HQ OPS Officer: DONG HWA PARK
Notification Date: 08/05/2013
Notification Time: 11:18 [ET]
Event Date: 08/05/2013
Event Time: 10:45 [EDT]
Last Update Date: 08/05/2013
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
JAMES TRAPP (R1DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 100 Power Operation
Event Text
HIGH RANGE STACK RADIATION MONITOR OUT OF SERVICE FOR MAINTENANCE:

"The Millstone Unit 2 high range stack radiation monitor is out for pre-planned maintenance. This is reportable in accordance with 10CFR50.72(b)(3)(xiii)."

The licensee has notified the NRC Resident Inspector, State, and local governments.


Agreement State
Event Number: 49238
Rep Org: NE DIV OF RADIOACTIVE MATERIALS
Licensee: OMAHA PUBLIC POWER DISTRICT
Region: 4
City: OMAHA   State: NE
County:
License #: 01-39-04
Agreement: Y
Docket:
NRC Notified By: RANDY LAMBERT
HQ OPS Officer: PETE SNYDER
Notification Date: 08/05/2013
Notification Time: 15:52 [ET]
Event Date: 08/05/2013
Event Time: 09:50 [CDT]
Last Update Date: 08/05/2013
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
MICHAEL VASQUEZ (R4DO)
FSME EVENT RESOURCE (EMAI)
Event Text
AGREEMENT STATE REPORT - SHUTTER STUCK ON A PROCESS GAUGE

The State of Nebraska submitted the following information via email:

"The licensee uses fixed industrial gauges for measuring levels in fly ash hoppers at the station's precipitator building. The industrial fixed gauges contain a Cesium 137 sealed source. The Cesium 137 sources were originally installed in April, 1984, and at the time contained 50 millicuries per source. The sources were manufactured and installed by Kay Ray Inc. The gauge that experienced the event was Kay Ray Gauge, Housing Model #7080 and housing serial number 16784H. The source capsule manufacture was Amersham model no. CDC 800 and K-R Ref. Number serial number 15095 V.

"In accordance with their license conditions two of the station's chemists were securing the Unit #5's precipitator sources in preparation for an inspection of the precipitator. The 'external' source closure mechanism for Unit #5 precipitator's 5FA-3E & 4E hoppers did not operate as designed and the shutter did not close when the handle on the floor was operated.

"The radiation sources, which are part of a hopper level sensor, are mounted between two fly ash hoppers 20 feet off the floor. The source closure mechanisms are connected to a handle located at the floor level by a flexible cable. These closure cables are secured to the structures so that when the handles are operated the control cables slide inside a sheath. On the 5FA-3E & 4E source, the shutter closure cable became loose up at the source which allowed the whole cable to slide back and forth when the handle was operated to try and close the shutter. This type of failure has been seen in the past and is easily fixed by tightening the screw which secures the end of the cable to the structure. This required a scaffold to be built up to the source level. A contractor came on site at 12:30 pm [CDT] on 8/5/2013 and erected a scaffold so repairs could be made."


Power Reactor
Event Number: 49239
Facility: LIMERICK
Region: 1     State: PA
Unit: [] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: DAN WILLIAMSON
HQ OPS Officer: PETE SNYDER
Notification Date: 08/05/2013
Notification Time: 21:38 [ET]
Event Date: 08/05/2013
Event Time: 14:56 [EDT]
Last Update Date: 08/05/2013
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
JAMES TRAPP (R1DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 100 Power Operation
Event Text
BOTH OFFSITE POWER SOURCES INOPERABLE DURING UNDERVOLTAGE TESTING

"Both Limerick 4 KV offsite sources were inoperable and Technical Specification 3.0.3 was entered for Unit 2 from 1456 to 1512 [EDT] during D23 4KV Undervoltage testing. During the undervoltage test, the affected diesel and one offsite source (101 Bus) are inoperable. During the test, the alternate offsite source (201 Bus) UV relay was tested and found to be inoperable, resulting in the need to declare the second offsite source (201 Bus) inoperable.

"When notified of the failure, action was taken to restore the 101 Bus offsite source to operable and exit the 3.0.3 condition [at] (1512 EDT). The 201 Bus Relay was successfully calibrated and tested to subsequently restore the 201 Bus to operability [at] (1543 EDT)."

Testing of the 201 bus UV relay is directed per procedure while the 101 bus is powered from the diesel generator.

The licensee notified the NRC Resident Inspector.


Agreement State
Event Number: 49244
Rep Org: TEXAS DEPARTMENT OF HEALTH
Licensee: MISTRAS GROUP INC.
Region: 4
City: TILDEN   State: TX
County:
License #: 06369
Agreement: Y
Docket:
NRC Notified By: IRENE CASARES
HQ OPS Officer: PETE SNYDER
Notification Date: 08/06/2013
Notification Time: 12:21 [ET]
Event Date: 08/05/2013
Event Time: 00:00 [CDT]
Last Update Date: 08/06/2013
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
MICHAEL VASQUEZ (R4DO)
FSME EVENT RESOURCE (EMAI)
Event Text
AGREEMENT STATE REPORT - STUCK RADIOGRAPHY CAMERA SOURCE

The State of Texas submitted the following information via email:

"On August 6, 2013, the Agency [Texas Department of Health] was notified by the licensee that on August 5, 2013, one of its radiography crews at a temporary work site near Tilden, Texas had a source disconnect on a QSA model 880D camera which contained an iridium-192 source. Authorized persons performed the source retrieval.

"The radiography two man crew pocket dosimeter readings were 188 and 22 millirem. Their dosimetry badges are being sent for processing. The two man retrieval team pocket dosimeters read 21 and 24 millirem. No member of the public received an exposure.

"The licensee is investigating the cause of the disconnect. All equipment is being sent for evaluation. Further information will be provided as it is obtained per SA-300."

TX Incident # I-9103


Power Reactor
Event Number: 49252
Facility: WATERFORD
Region: 4     State: LA
Unit: [3] [] []
RX Type: [3] CE
NRC Notified By: WILLIAM HARDIN
HQ OPS Officer: CHARLES TEAL
Notification Date: 08/08/2013
Notification Time: 19:52 [ET]
Event Date: 08/05/2013
Event Time: 14:30 [CDT]
Last Update Date: 08/08/2013
Emergency Class: NON EMERGENCY
10 CFR Section:
26.719 - FITNESS FOR DUTY
Person (Organization):
MICHAEL VASQUEZ (R4DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
3 N Y 100 Power Operation 100 Power Operation
Event Text
AN OFF-DUTY LICENSED OPERATOR WAS ARRESTED FOR DRIVING UNDER THE INFLUENCE

A off-duty licensed operator was arrested while driving a vehicle under the influence of alcohol. This was determined to violate the Waterford Fitness for Duty program. The individual has been administratively removed from performing licensed duties pending investigation.

The licensee has notified the NRC Resident Inspector.


Agreement State
Event Number: 49320
Rep Org: KANSAS DEPT OF HEALTH & ENVIRONMENT
Licensee: CODER X-RAY SERVICE
Region: 4
City: MCPHERSON   State: KS
County:
License #: 21-B165-01
Agreement: Y
Docket:
NRC Notified By: JAMES HARRIS
HQ OPS Officer: BILL HUFFMAN
Notification Date: 09/04/2013
Notification Time: 15:07 [ET]
Event Date: 08/05/2013
Event Time: 00:00 [CDT]
Last Update Date: 09/04/2013
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
VINCENT GADDY (R4DO)
FSME EVENT RESOURCES (E-MA)
Event Text
AGREEMENT STATE REPORT - FAILURE OF RADIOGRAPHY SOURCE TO RETRACT

The following report was received from the Kansas Bureau of Environmental Health via facsimile:

"During radiography operations on the night of 5 Aug 2013, two employees, a radiographer and an assistant radiographer of Coder Welding & X-ray Service were finishing an 8 hour shift (which is 2nd shift for Alstom), when the source and crank assembly would not operate correctly. At that time, they could only determine that the source had not fully retracted into the camera correctly. After several additional attempts, they concluded a malfunction of unknown causes prevented the source from retracting to a full and locked condition. Following Coder Operating and Emergency protocol, the first action was to secure and maintain a 2mr/hr boundary. A complete survey of the area determined that the original roped and placarded boundaries were still correct and valid. Next the RSO was contacted as well as the assistant RSO. The RSO advised the radiographer to secure and maintain the 2mr/hr boundary and asked if any personnel or workers had been exposed to radiation levels in excess of those in Kansas Radiation Protection Regulations, Part 4 and following, and they stated no. They were advised that the RSO would be on site in 90 minutes to oversee the incident and resolve the situation. While waiting for the RSO to arrive, the two Coder employees decided to extend the roped boundaries an additional 75 feet in addition to the existing roped area and inform Alstom management of the situation. Since this was the end of 2nd shift for Alstom workers, and no Alstom workers were in the area at the time, there was no disruption of production or evacuation needed. Any Alstom employees on site were advised not to enter plant area as a precaution. At no time were Coder or Alstom employees at risk or in danger of overexposure.

"The RSO arrived on site at approximately 12:15 p.m. and made a radiation survey of the area and boundaries. The RSO found correct actions had been taken and 2mr/hr boundaries were maintained. In fact, 1mr/hr was the highest reading. The RSO then walked up to the crank-out reel and found the radiation level to be 5mr/hr. He concluded that the source was in fact in the tungsten collimator (4.3 hvl [half value integers]) secured on the pipe weld where it was during earlier radiographic operations. Several attempts to return the source to its shielded and locked condition failed, so plans were made to allow for closer inspection of the cables and source tube. At this point, the assistant RSO was contacted and advised to bring additional drive cables and source tube in the event they could be needed. While the radiographer and assistant radiographer maintained security over the boundaries and source, the RSO and several Alstom management, who had arrived on site, went outside to look for suitable shielding that could be brought in. Two one inch plates were chosen for use. The plates were tack welded together and moved to an area where overhead cranes could be used to move into position. This was accomplished by using the remote controls of the crane system so no person would have to be in a high radiation environment. With help from Alstom personnel, the steel plates were directed into place by the RSO next to the source camera, providing additional shielding. It was then possible for the RSO to walk up to the source camera with a survey level of 32mr/hr. It was then possible to inspect the drive cables and look at the source tube for possible causes of the return failure. A small depression was noted some 6 to 7 feet from the camera and cable attachment. Using a hacksaw, pliers, and other tools, the outer cable shielding was removed and the RSO returned to the cable crank, and was able to retract the source into the camera in the full and locked position. During the entire operation the RSO received a whole body dose of 35 mr.

"Due to the time and distance for the RSO, late arrival of the assistant RSO arrival on site, and the caution taken to resolve the situation, some 3-1/2 hours elapsed from the start to the end. The help and materials provided by Alstom management aided in the safe and satisfactory conclusion of this incident. At this time, it is unknown what might have caused the depression in drive cables or why it suddenly caused a failure to retract situation."

Kansas Report Number: KS130006