Skip to main content

Event Notification Report for May 21, 2013

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
05/20/2013 - 05/21/2013

EVENT NUMBERS
4905449056

Power Reactor
Event Number: 49054
Facility: CALVERT CLIFFS
Region: 1     State: MD
Unit: [] [2] []
RX Type: [1] CE,[2] CE
NRC Notified By: AMI CORDER
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 05/21/2013
Notification Time: 06:20 [ET]
Event Date: 05/21/2013
Event Time: 05:33 [EDT]
Last Update Date: 05/21/2013
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
MEL GRAY (R1DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 M/R Y 100 Power Operation 0 Hot Standby
Event Text
MANUAL REACTOR TRIP AFTER A FEED PUMP TRIP

"Reactor trip. All safety functions met with normal heat removal. 22 SGFP [Steam Generator Feedpump] exhibited high vibrations and signs of coupling damage. Further investigation will be performed."

All control rods fully inserted on the trip. Steam Generator level is being maintained with the remaining feedpump. Decay heat is being dumped to the main condenser. Electrical power is in the normal shutdown lineup. No relief or safety valves lifted during the trip. There was no effect on Unit 1.

The licensee notified the NRC Resident Inspector.


Power Reactor
Event Number: 49056
Facility: FORT CALHOUN
Region: 4     State: NE
Unit: [1] [] []
RX Type: (1) CE
NRC Notified By: SCOTT MOECK
HQ OPS Officer: JOHN SHOEMAKER
Notification Date: 05/21/2013
Notification Time: 22:15 [ET]
Event Date: 05/21/2013
Event Time: 12:00 [CDT]
Last Update Date: 05/21/2013
Emergency Class: NON EMERGENCY
10 CFR Section:
26.719 - FITNESS FOR DUTY
Person (Organization):
NEIL OKEEFE (R4DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Cold Shutdown 0 Cold Shutdown
Event Text
FITNESS-FOR-DUTY REPORT INVOLVING A NON-LICENSED CONTRACT SUPERVISOR

A non-licensed, contract supervisory employee failed a random fitness-for-duty test. The employee's access to the plant has been revoked.

The licensee informed the NRC Resident Inspector.