!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 48870
Facility: PRAIRIE ISLAND
Region: 3     State: MN
Unit: [1] [2] []
RX Type: [1] W-2-LP,[2] W-2-LP
NRC Notified By: WAYNE EPPEN
HQ OPS Officer: HOWIE CROUCH
Notification Date: 03/31/2013
Notification Time: 15:07 [ET]
Event Date: 03/30/2013
Event Time: 23:44 [CDT]
Last Update Date: 05/13/2013
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(C) - POT UNCNTRL RAD REL
Person (Organization):
JULIO LARA (R3DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
Event Text
BOTH TRAINS OF AUXILIARY BUILDING SPECIAL VENTILATION SYSTEM DECLARED INOPERABLE

"During testing of the Auxiliary Building Ventilation System it was discovered that the outlet damper of one of the normal make-up fans did not close. This created a non-closable opening in the Auxiliary Bldg Special Vent System (ABSVS) boundary of greater than 10 square feet and required entry into TS [Technical Specification] 3.7.12, Condition B, for two ABSVS trains inoperable due to inoperable ABSVS boundary. This is considered a potential loss of safety function to control the release of material."

The licensee has notified the NRC Resident Inspector.

* * * RETRACTION FROM MARK LOOSBROCK TO PETE SNYDER ON 5/13/13 AT 1639 EDT * * *

"This notification is being made to retract Event Notification (EN) #48870, which reported a non-closeable opening in the Auxiliary Building Special Vent System (ABSVS) boundary of greater than 10 square feet. This required entry into TS 3.7.12 Condition B for two ABSVS trains inoperable due to an inoperable ABSVS boundary. This was considered a potential loss of safety function to control the release of radioactive material.

"Engineering evaluation and analysis identified that there was not a loss of safety function because the ABSVS started on demand during the performance of SP 1172 and that the ABSVS Boundary never exceeded the Tech Spec value of 10 square feet per TS 3.7.12. Review of the work order for CD-34042 validated that the system would have performed its safety function during the failure of CD-34042. In the event of a Design Basis Accident the ABSVS would have received a signal to actuate, the system would have performed as designed and drawn a negative differential pressure in the Aux Bldg within 6 minutes with the identified opening of 9.62 square feet that was observed during the failure of CD-34042."

The licensee notified the NRC Resident Inspector. Notified R3DO (Riemer).


Agreement State
Event Number: 48875
Rep Org: NC DIV OF RADIATION PROTECTION
Licensee: GOODYEAR TIRE & RUBBER COMPANY
Region: 1
City: FAYETTEVILLE   State: NC
County:
License #: 026-0352-0G
Agreement: Y
Docket:
NRC Notified By: WILLIAM JOHNSON
HQ OPS Officer: PETE SNYDER
Notification Date: 04/02/2013
Notification Time: 13:24 [ET]
Event Date: 03/30/2013
Event Time: 17:08 [EDT]
Last Update Date: 04/02/2013
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
JAMES DWYER (R1DO)
FSME EVENT RESOURCE (EMAI)
Event Text
AGREEMENT STATE REPORT - FIRE IN PLANT MAY HAVE DAMAGED TWO PROCESS GAUGES

The following information was received via facsimile:

Two process gauges containing Sr-90 (approximately 50 mCi ea.) at the Goodyear Tire and Rubber Company facility in Fayetteville, NC may have sustained damage as a result of a fire. No leakage is reported. The gauges were mounted in a "LOW - Minimal or Low risk area."

The State of North Carolina will be investigating.

NC Incident No. 13-06.