Event Number: 48554
Facility: GLOBAL NUCLEAR FUEL - AMERICAS
Region: 2     State: NC
Unit: [] [] []
RX Type: URANIUM FUEL FABRICATION
Comments: LEU CONVERSION (UF6 TO UO2)
LEU FABRICATION
LWR COMMERICAL FUEL
NRC Notified By: SCOTT MURRAY
HQ OPS Officer: PETE SNYDER
Notification Date: 12/04/2012
Notification Time: 13:03 [ET]
Event Date: 12/03/2012
Event Time: 13:30 [EST]
Last Update Date: 12/05/2012
Emergency Class: NON EMERGENCY
10 CFR Section:
PART 70 APP A (b)(1) - UNANALYZED CONDITION
Person (Organization):
ALAN BLAMEY (R2DO)
MERAJ RAHIMI (NMSS)
Event Text
ITEMS RELIED ON FOR SAFETY ASSOCIATED WITH THE DRY SCRAP RECYCLE FURNACE IMPROPERLY ANALYZED

"During a [Global Nuclear Fuels] GNF-A review of the Fuel Manufacturing Operation (FMO) Integrated Safety Analysis (ISA), it was determined at 1:30 PM yesterday (12/3/12) that Items Relied on for Safety (IROFS) associated with the Dry Scrap Recycle furnace operation were improperly analyzed in the ISA. Although criticality controls associated with preventing moderation intrusion exist and these controls remained in place, they were not sufficiently independent to meet performance requirements.

"At no time was an unsafe condition present. The affected equipment has been shut down. An investigation is continuing which will provide additional corrective actions and extent of condition.

"While this did not result in an unsafe condition, this event is being reported pursuant with the reporting requirements of 10CFR70 Appendix A (b)(1) within 24 hours of discovery."

The licensee will notify state and local governmental agencies and has notified the onsite NRC Inspectors.

* * * UPDATE FROM SCOTT MURRAY TO PETE SNYDER AT 1600 EST ON 12/5/12 * * *

"An extent of condition review determined there are three more areas with IROFS that are not sufficiently independent. These areas are vaporization/conversion of the Dry Conversion Process, an area used to pack material for recovery and a hood that is used to transition to a moderation restricted area in the gadolinia shop. The affected equipment in these areas has also been shut down and the investigation continues to identify additional corrective actions."

The licensee notified the onsite NRC Inspectors. Notified R2DO (Blamey) and NMSS (Rahimi).