Skip to main content

Event Notification Report for January 16, 2012

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
01/15/2012 - 01/16/2012

EVENT NUMBERS
4759647599

Power Reactor
Event Number: 47596
Facility: FITZPATRICK
Region: 1     State: NY
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: JORGE O'FARRILL
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 01/16/2012
Notification Time: 08:30 [ET]
Event Date: 01/16/2012
Event Time: 03:30 [EST]
Last Update Date: 01/16/2012
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
JAMES TRAPP (R1DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 88 Power Operation 88 Power Operation
Event Text
TECHNICAL SUPPORT CENTER VENTILATION DAMPER FAILURE

"At 0330 EST on 01/16/12, it was discovered that due to the failure of the Technical Support Center (TSC) ventilation system to align during testing, the TSC was rendered non-functional. Repairs are underway. An update will be provided once the TSC ventilation has been restored to normal operation.

"If an emergency is declared requiring TSC activation during this period, the TSC will be staffed and activated using existing emergency planning procedures unless the TSC becomes uninhabitable due to ambient temperature, radiological, or other conditions. If relocation of the TSC becomes necessary, the station Emergency Plant Manager will relocate the TSC staff to an alternate location in accordance with applicable site procedures giving first consideration to the Control Room. TSC facility leads have been made aware of this contingency.

"This notification is being made in accordance with 10 CFR 50.72(b)(3)(xiii) due to the potential loss of an emergency response facility.

"The NRC Senior Resident Inspector has been informed."

* * * UPDATE AT 1525 EST ON 01/16/12 FROM JORGE O'FARRILL TO S. SANDIN * * *

"Corrective maintenance was completed 01/16/2012 at 1042 EST to restore the TSC filtered ventilation capability. Post maintenance testing was completed satisfactorily [on] 01/16/2012 [at] 1335 EST. JAF's TSC has been restored and is now functional."

The licensee informed state/local agencies as a courtesy and the NRC Resident Inspector. Notified R1DO (Trapp).


Non-Agreement State
Event Number: 47599
Rep Org: AVERA MCKENNAN HOSPITAL
Licensee: AVERA MCKENNAN HOSPITAL
Region: 4
City: SIOUX FALLS   State: SD
County: MINNEHAHA
License #: 4016571-01
Agreement: N
Docket:
NRC Notified By: RICHARD MASSOTH
HQ OPS Officer: VINCE KLCO
Notification Date: 01/17/2012
Notification Time: 13:04 [ET]
Event Date: 01/16/2012
Event Time: 16:00 [MST]
Last Update Date: 04/12/2012
Emergency Class: NON EMERGENCY
10 CFR Section:
35.3045(a)(1) - DOSE <> PRESCRIBED DOSAGE
Person (Organization):
GREG PICK (R4DO)
ANGELA MCINTOSH (FSME)
Event Text
MEDICAL EVENT DUE TO POTENTIAL DIFFERENT FRACTIONAL DOSE DELIVERED THAN PRESCRIBED

The licensee provided notification that a patient received 2 occurrences of a dose less than prescribed when delivering ten fractions of a treatment. Each of the underdoses were approximately 50% of the 340 Gray prescribed fractional dose. The patient will receive additional dose fractions in order to achieve the written directive total dose. The Radiation Oncologist has notified the patient and attending physician.

* * UPDATE FROM RICHARD MASSOTH TO JOHN KNOKE AT 1826 EST ON 01/31/12 * *

"On January 17, 2012 the NRC Operations Center was verbally notified of two Therapeutic Underdose Occurrences discovered by the licensee on January 16 and 17, 2012. These occurrences involved a fractionated Breast High Dose Rate Afterloader (HDR) treatment with a SenoRx Contura multicatheter breast applicator. The first and third delivered treatment fractions were found to be less than 50% of the intended fractional dose. The entire course of the treatment in the written directive included ten equal-dose fractions of 3.4 Gray per fraction for a total dose of 34 Gray to the prescribed treatment site. To correct for the underdose occurrences, two additional treatment fractions were added and the treatment plan was modified to achieve the total dose specified in the written directive.

"The licensee now believes that this medical event has also caused an unintended dose to skin outside of the prescribed treatment site, requiring notification under 10CFR35.3045(a)(3). The licensee has performed computer simulation, calculations and physical measurements using TLDs simulating the treatment geometry to model the unintended skin dose. The event delivered an unintended skin dose exceeding at least the skin erythema threshold (2 Gy). The licensee is continuing to monitor the patient response to the skin dose and is working to refine the unintended skin dose estimates. An NRC reactive inspection team is on-site."

Notified R4DO (Jeff Clark) and FSME (Greg Suber)

* * * UPDATE FROM TRACI HOLLINGSHEAD TO HOWIE CROUCH AT 1044 EDT ON 4/12/12 * * *

The licensee confirmed that they agree with their medical consultants' findings that the patient received approximately 2720 rads of unintended skin dose.

Notified R4DO (Gaddy) and FSME (McIntosh).

A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.