469284692946930

Power Reactor
Event Number: 46928
Facility: SAINT LUCIE
Region: 2     State: FL
Unit: [] [2] []
RX Type: [1] CE,[2] CE
NRC Notified By: ROBERT WEBBER
HQ OPS Officer: PETE SNYDER
Notification Date: 06/06/2011
Notification Time: 07:04 [ET]
Event Date: 06/06/2011
Event Time: 03:29 [EDT]
Last Update Date: 06/06/2011
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
JOSELITO CALLE (R2DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 A/R Y 100 Power Operation 0 Hot Standby
Event Text
ERROR DURING REACTOR PROTECTION SYSTEM SURVEILLANCE LEADS TO REACTOR TRIP

"On June 6, 2011, during the performance of Reactor Protection System Logic Matrix Testing, a Reactor Trip occurred. All CEA's [Control Element Assemblies] fully inserted into the core. Decay Heat removal was initially from Auxiliary Feedwater and Steam Bypass to the Main Condenser. All equipment operated as expected. Currently maintaining pressurizer pressure at 2250 psia, temperature maintaining at 532 degrees F. Auxiliary Feedwater actuated as designed. As of 0435, decay heat removal is via Main Feedwater and Steam Bypass control to Main Condenser.

"During the transfer of Auxiliary Feedwater to Main Feedwater a second AFAS actuation occurred.

"Unit 1 was unaffected and remains in Mode 1 at 100% power.

"This event is reportable pursuant to 10CFR 50.72(b)(2)(iv)(B) for the Reactor Trip, as well as 10CFR50.72(b)(3)(iv)(A) for specified system actuation (Auxiliary Feedwater)."

The licensee notified the NRC Resident Inspector.


Power Reactor
Event Number: 46929
Facility: FORT CALHOUN
Region: 4     State: NE
Unit: [1] [] []
RX Type: (1) CE
NRC Notified By: ROBERT CROSS
HQ OPS Officer: CHARLES TEAL
Notification Date: 06/06/2011
Notification Time: 09:12 [ET]
Event Date: 06/06/2011
Event Time: 08:00 [CDT]
Last Update Date: 08/29/2011
Emergency Class: UNUSUAL EVENT
10 CFR Section:
50.72(a) (1) (i) - EMERGENCY DECLARED 50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
JACK WHITTEN (R4DO)
JOHN THORP (NRR)
ELMO COLLINS (R4)
BRUCE BOGER (NRR)
JANE MARSHALL (IR)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Cold Shutdown 0 Cold Shutdown
Event Text
UNUSUAL EVENT DECLARED DUE TO RIVER LEVEL

"At 0800 CDT a Notification of Unusual Event (HU 1, EAL 5) for operating mode less than 210 degrees F is being declared for a river level expected to exceed a 1004' MSL (Mean Sea Level), but less than or equal to 1009' MSL elevation. Currently Abnormal Operating Procedure AOP-1 is being implemented for high river level, as well as, PE-RR-AE-1001 for Flood Barrier and Sandbag Staging and Installation. This condition is being reported pursuant to 10 CFR 50.72(a)(1)(i) for declaration of an emergency class specified in the licensee's approved emergency plan. Applicable governmental agencies have been notified per plant procedures. No press release is expected at this time."

* * * UPDATE FROM ERICK MATZKE TO PETE SNYDER AT 1121 EDT ON 6/6/2011 * * *

"During the emergency notification the automated paging function did not cause the pagers to actuate. The issue is being investigated." A notification for 10 CFR 50.72(b)(3)(xiii) be added to the header.

Notified R4DO (Whitten).

* * * UPDATE FROM ERICK MATZKE TO HOWIE CROUCH AT 1305 EDT ON 6/6/2011 * * *

"OPPD will be making a press release for this event at about 1220 CDT."

The licensee will be notifying the NRC Resident Inspector. Notified R4DO (Whitten) and HQPAO (Brenner).

* * * UPDATE FROM AMY BURKHART TO HOWIE CROUCH AT 1449 EDT ON 8/29/11 * * *

"At 1342 CDT on 08/29/11, FCS [Fort Calhoun Station] terminated the Notification of Unusual Event for flooding. Missouri river level receded to less than entry criteria and is currently 1003.56 ft MSL."

The licensee has notified the State of Nebraska, Harrison County, Washington County, and Pottawattamie County of the termination. Notified R4DO (Proulx), IRD (Marshall), NRR (Thorp), DHS (Rickerson), and FEMA (Dennis).


Power Reactor
Event Number: 46930
Facility: KEWAUNEE
Region: 3     State: WI
Unit: [1] [] []
RX Type: [1] W-2-LP
NRC Notified By: BRAD GAUGER
HQ OPS Officer: BILL HUFFMAN
Notification Date: 06/06/2011
Notification Time: 16:26 [ET]
Event Date: 06/06/2011
Event Time: 09:00 [CDT]
Last Update Date: 06/06/2011
Emergency Class: NON EMERGENCY
10 CFR Section:
26.719 - FITNESS FOR DUTY
Person (Organization):
JULIO LARA (R3DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
FITNESS FOR DUTY REPORT INVOLVING A CONTRACTOR SUPERVISOR

A contractor supervisor had a confirmed positive for an illegal substance during a random fitness-for-duty test. The employee's access has been suspended. Contact the Headquarters Operations Officer for additional details.