Event Notification Report for February 27, 2011

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
02/26/2011 - 02/27/2011

EVENT NUMBERS
46646

Power Reactor
Event Number: 46646
Facility: POINT BEACH
Region: 3     State: WI
Unit: [] [2] []
RX Type: [1] W-2-LP,[2] W-2-LP
NRC Notified By: RUSS PARKER
HQ OPS Officer: VINCE KLCO
Notification Date: 02/28/2011
Notification Time: 03:45 [ET]
Event Date: 02/27/2011
Event Time: 21:59 [CST]
Last Update Date: 02/28/2011
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
DAVID HILLS (R3DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 100 Power Operation
Event Text
DEGRADED ACCIDENT MITIGATION DUE TO SAFETY INJECTION OUT OF SERVICE

"At 2159 CST on 2/27/2011, during the testing of the 'A' Train Safety Injection System, an Auxiliary Operator in the field identified that the oiler for 2P-15B, 'B' Train Safety Injection Pump, had rotated and the oil had drained out of the oiler. The Auxiliary Operator immediately reported this condition to control room personnel. The 'B' train safety injection pump was declared inoperable and LCO 3.0.3 was entered based upon the condition of both trains of safety injection being out of service. The Unit 2 'A' Train Safety Injection System was being tested in accordance with inservice testing procedure IT-535C, Leakage Reduction and Preventive Maintenance Program Train 'A' HHSI and RHR Piggyback Test Mode 1,5,6 (Refueling) Unit 2, which placed the Unit 2 ECCS in TSAC [Technical Specification Action Condition] 3.5.2.A, One ECCS Train Inoperable.

"Unit 2 exited LCO 3.0.3 at 2211 CST, upon completion of the 'A' train inservice test. The 2P-151B safety injection pump remains inoperable in accordance with TSAC 3.5.2.A, One ECCS Train Inoperable for troubleshooting and repair. This condition is reported in accordance with 10 CFR 50.72(b)(3)(v)(D) Accident Mitigation."

There was no impact on Unit 1 and the licensee notified the NRC Resident Inspector.