Event Notification Report for February 14, 2011
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
02/13/2011 - 02/14/2011
Power Reactor
Event Number: 46613
Facility: FITZPATRICK
Region: 1 State: NY
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: DAVID RICHARDSON
HQ OPS Officer: JOE O'HARA
Region: 1 State: NY
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: DAVID RICHARDSON
HQ OPS Officer: JOE O'HARA
Notification Date: 02/14/2011
Notification Time: 03:09 [ET]
Event Date: 02/14/2011
Event Time: 07:00 [EST]
Last Update Date: 02/14/2011
Notification Time: 03:09 [ET]
Event Date: 02/14/2011
Event Time: 07:00 [EST]
Last Update Date: 02/14/2011
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
RONALD BELLAMY (R1DO)
RONALD BELLAMY (R1DO)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
TECHNICAL SUPPORT CENTER VENTILATION OUT OF SERVICE FOR PLANNED MAINTENANCE
"A planned maintenance evolution at the James A. FitzPatrlck (JAF) Nuclear Power Plant will remove the Technical Support Center (TSC) ventilation system from service. Therefore, the TSC ventilation system will be rendered non-functional during the course of the work activities. The TSC ventilation is expected to be out of service for approximately 13 hours from 0700 to 2000 today.
"If an emergency Is declared requiring TSC activation during this period, the TSC will be staffed and activated using existing emergency planning procedures unless the TSC becomes uninhabitable due to ambient temperature, radiological, or other conditions. If relocation of the TSC becomes necessary, the station Emergency Plant Manager will relocate the TSC staff to an alternate TSC location in accordance with applicable site procedures giving first consideration to the Control Room. TSC facility leads have been made aware of this contingency.
"This notification Is being made in accordance 10 CFR 50.72 (b)(3)(xiii) due to the potential loss of an emergency response facility (ERF). An update will be provided once the TSC ventilation has been restored to normal operation."
The NRC Resident Inspector has been notified.
* * * UPDATE FROM DAVID RICHARDSON TO DONALD NORWOOD ON 2/14/2011 AT 1922 EST * * *
"As of 1839 hours today, the planned maintenance activity on the Technical Support Center (TSC) ventilation system is complete. Post-work testing is complete and the system has been restored to fully functional."
The NRC Resident Inspector has been notified.
Notified R1DO (Ferdas).
"A planned maintenance evolution at the James A. FitzPatrlck (JAF) Nuclear Power Plant will remove the Technical Support Center (TSC) ventilation system from service. Therefore, the TSC ventilation system will be rendered non-functional during the course of the work activities. The TSC ventilation is expected to be out of service for approximately 13 hours from 0700 to 2000 today.
"If an emergency Is declared requiring TSC activation during this period, the TSC will be staffed and activated using existing emergency planning procedures unless the TSC becomes uninhabitable due to ambient temperature, radiological, or other conditions. If relocation of the TSC becomes necessary, the station Emergency Plant Manager will relocate the TSC staff to an alternate TSC location in accordance with applicable site procedures giving first consideration to the Control Room. TSC facility leads have been made aware of this contingency.
"This notification Is being made in accordance 10 CFR 50.72 (b)(3)(xiii) due to the potential loss of an emergency response facility (ERF). An update will be provided once the TSC ventilation has been restored to normal operation."
The NRC Resident Inspector has been notified.
* * * UPDATE FROM DAVID RICHARDSON TO DONALD NORWOOD ON 2/14/2011 AT 1922 EST * * *
"As of 1839 hours today, the planned maintenance activity on the Technical Support Center (TSC) ventilation system is complete. Post-work testing is complete and the system has been restored to fully functional."
The NRC Resident Inspector has been notified.
Notified R1DO (Ferdas).
Power Reactor
Event Number: 46614
Facility: BYRON
Region: 3 State: IL
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: ROB LAWLOR
HQ OPS Officer: DONALD NORWOOD
Region: 3 State: IL
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: ROB LAWLOR
HQ OPS Officer: DONALD NORWOOD
Notification Date: 02/14/2011
Notification Time: 15:12 [ET]
Event Date: 02/14/2011
Event Time: 09:20 [CST]
Last Update Date: 02/14/2011
Notification Time: 15:12 [ET]
Event Date: 02/14/2011
Event Time: 09:20 [CST]
Last Update Date: 02/14/2011
Emergency Class: NON EMERGENCY
10 CFR Section:
26.719 - FITNESS FOR DUTY
10 CFR Section:
26.719 - FITNESS FOR DUTY
Person (Organization):
LAURA KOZAK (R3DO)
LAURA KOZAK (R3DO)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
FITNESS FOR DUTY REPORT INVOLVING A NON-LICENSED SUPERVISOR
A non-licensed employee supervisor had a confirmed positive for alcohol during a random fitness-for-duty test. The employee's access to the plant has been suspended. Contact the Headquarters Operations Officer for additional details.
The licensee informed the NRC Resident Inspector.
A non-licensed employee supervisor had a confirmed positive for alcohol during a random fitness-for-duty test. The employee's access to the plant has been suspended. Contact the Headquarters Operations Officer for additional details.
The licensee informed the NRC Resident Inspector.