Skip to main content

Event Notification Report for December 28, 2010

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
12/27/2010 - 12/28/2010

EVENT NUMBERS
4651546566

Power Reactor
Event Number: 46515
Facility: FERMI
Region: 3     State: MI
Unit: [2] [] []
RX Type: [2] GE-4
NRC Notified By: GREG MILLER
HQ OPS Officer: DONALD NORWOOD
Notification Date: 12/28/2010
Notification Time: 16:27 [ET]
Event Date: 12/28/2010
Event Time: 12:20 [EST]
Last Update Date: 12/28/2010
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
JULIO LARA (R3DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 75 Power Operation 75 Power Operation
Event Text
HIGH PRESSURE COOLANT INJECTION SYSTEM INOPERABLE DUE TO INOPERABLE MINIMUM FLOW VALVE

"On December 28, 2010 at approximately 1220 hours, during surveillance testing of the High Pressure Coolant Injection (HPCI) system, abnormal control room position indication was observed on the HPCI Minimum Flow Valve, E4150F012 as the valve was stroking closed. HPCI had been removed from service for quarterly surveillance testing at 0950 hours. The unplanned inoperability condition began at 1220 hours when position indication was lost on the minimum flow valve. The valve was manually closed to comply with the action of LCO 3.6.1.3 to isolate the penetration. A 14 day LCO was entered and back dated to the time that HPCI was removed from service per LCO 3.5.1. This report is being made pursuant to 10CFR50.72(b)(3)(v)(D) as a condition that at the time of discovery could have prevented the fulfillment of a safety function needed to mitigate the consequences of an accident, based on loss of a single train safety system. RCIC was and has remained operable. The failure is currently under investigation."

The licensee notified the NRC Resident Inspector.


Agreement State
Event Number: 46566
Rep Org: MISSISSIPPI DIV OF RAD HEALTH
Licensee: CARDINAL HEALTH
Region: 4
City: JACKSON   State: MS
County:
License #: MS-493-01
Agreement: Y
Docket:
NRC Notified By: JAYSON MOAK
HQ OPS Officer: VINCE KLCO
Notification Date: 01/24/2011
Notification Time: 15:55 [ET]
Event Date: 12/28/2010
Event Time: 00:00 [CST]
Last Update Date: 01/24/2011
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
GEOFFREY MILLER (R4DO)
BILL VON TILL (FSME)
MICHAEL WATERS (NMSS)
Event Text
AGREEMENT STATE REPORT - TRANSPORTATION ACCIDENT INVOLVING RADIOPHARMACEUTICALS

The following information was received by email:

"DRH [Mississippi State Department of Health] was notified at 0720 [CST], about a transportation accident in Jackson, MS, on Riverside Drive. Cardinal Health Nuclear Pharmacy Services was delivering radiopharmaceuticals to Baptist Hospital and Kings Daughters Hospital. The driver hit an icy patch on the road where a water main had broken. The driver lost control of the delivery vehicle. The vehicle turned over in the median and the driver was trapped. DRH responded at 0730 [CST]. The driver was not injured. Packages were dislodged from their protective security rack, that is required to prevent shifting and movement of packages. Radiopharmaceutical packages were surveyed and wiped for contamination. [No contamination was detected.] The packages were picked up by the Radiation Safety Officer so they could be delivered to the hospitals. The pharmacy's vehicle was then released to the wrecker service."

DRH closed this case on 12/28/2010.

MS Report No.: MS-10010.