Skip to main content

Event Notification Report for September 10, 2010

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
09/09/2010 - 09/10/2010

EVENT NUMBERS
46244

Fuel Cycle Facility
Event Number: 46244
Facility: GLOBAL NUCLEAR FUEL - AMERICAS
Region: 2     State: NC
Unit: [] [] []
RX Type: URANIUM FUEL FABRICATION
Comments: LEU CONVERSION (UF6 TO UO2)
LEU FABRICATION
LWR COMMERICAL FUEL
NRC Notified By: SCOTT MURRAY
HQ OPS Officer: VINCE KLCO
Notification Date: 09/10/2010
Notification Time: 17:00 [ET]
Event Date: 09/10/2010
Event Time: 10:00 [EDT]
Last Update Date: 09/10/2010
Emergency Class: NON EMERGENCY
10 CFR Section:
PART 70 APP A (b)(2) - LOSS OR DEGRADED SAFETY ITEMS
Person (Organization):
ROBERT HAAG (R2DO)
SHEENA WHALEY (NMSS)
Event Text
DEGRADATION OF SAFETY EQUIPMENT

"At approximately 1000 [EDT] on September 10, 2010 during normal operation of a Gad slugger feed hood in the Fuel Manufacturing Building, a connection between the powder hopper and the vibrating feeder was observed as being not properly secured. After starting the vibrating feeder a small amount of powder leaked from the vibrating feeder into the hood. The base of the hood is equipped with a photo-sensor that detected the powder accumulation and automatically shut down the vibrating feeder to stop the leak. A total of 2.2 kg of powder was removed from the hood. An investigation determined that a clamp on the feed tube had not been properly reinstalled following an equipment cleanout.

"The two controlled parameters for criticality safety of this equipment are moderation and geometry and Items Relied on for Safety (IROFS) are established for both. With the clamp improperly installed, the geometry-related IROFS was in a degraded state. Additional IROFS on moderation remained available to perform their intended safety functions and were not challenged. Geometry control was maintained by the photo-sensor interlock; however this IROFS is not credited for this accident sequence in the ISA.

"Although, this event did not result in an unsafe condition and double contingency was maintained, the performance requirements could not be met when taking no credit for the degraded IROFS. As a result, this report is conservatively being made per 10CFR70 Appendix A (b)(2).

"The Gad slugger and similar equipment have been shutdown pending implementation of additional corrective actions."

The licensee will notify the NRC Region 2 Office, the North Carolina Radiation Protection Section and the New Hanover County Emergency Preparedness Organization.