Skip to main content

Event Notification Report for July 08, 2010

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
07/07/2010 - 07/08/2010

EVENT NUMBERS
4607846079

General Information or Other
Event Number: 46078
Rep Org: VIRGINIA RAD MATERIALS PROGRAM
Licensee: POLYMER GROUP INC
Region: 1
City: WAYNESBORO   State: VA
County:
License #: 1031
Agreement: Y
Docket:
NRC Notified By: MICHAEL WELLING
HQ OPS Officer: DONG HWA PARK
Notification Date: 07/08/2010
Notification Time: 15:25 [ET]
Event Date: 07/08/2010
Event Time: 00:00 [EDT]
Last Update Date: 07/09/2010
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
ANTHONY DIMITRIADIS (R1DO)
KEVIN HSUEH (FSME)
ILTAB VIA EMAIL
Event Text
AGREEMENT STATE REPORT - MISSING THICKNESS GAUGE

The following information was received from the Commonwealth of Virginia via email:

"On July 8, 2010 the licensee reported a missing thickness gauge, NDC Model 103, serial number 3794. The gauge contains a 150 milliCurie Americium-241 sealed source. The gauge had been in storage for several years and was last visually verified in March 2010. It was discovered to be missing on the morning of July 8th. The licensee stated that the original labels were on the gauge and that the gauge housing was intact. The licensee has initiated a site search and has conducted interviews with personnel."

Event Report No.: VA-10-05

* * * UPDATE FROM MICHAEL WELLING TO CHARLES TEAL ON 7/9/10 AT 1559 * * *

"On July 9, 2010 a Radiation Safety Specialist from the Virginia Radioactive Materials Program performed an investigation at Polymer Group, Inc.'s site. During the investigation, a radiation survey of the storage location was performed which indicated 20 mrem/hr. Further investigation revealed that the spring on two NDC 103 gamma gauges shutters were not properly working, thus leaving the shutter open. The shutters were placed in their closed position and tape secured over them to ensure their position. A lock was placed on the storage cabinet to ensure further security of the remaining gauges. Polymer Group, Inc. is working with a licensed broker for proper disposal of the remaining 5 gauges. A visual inspection of the facility was performed and all employees were questioned. The gauge remains lost at this time."

Notified R1DO (Dimitriadis) and FSME EO (Hsueh).

THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf


Fuel Cycle Facility
Event Number: 46079
Facility: NUCLEAR FUEL SERVICES INC.
Region: 2     State: TN
Unit: [] [] []
RX Type: URANIUM FUEL FABRICATION
Comments: HEU CONVERSION & SCRAP RECOVERY
NAVAL REACTOR FUEL CYCLE
LEU SCRAP RECOVERY
NRC Notified By: RIK DROKE
HQ OPS Officer: DONG HWA PARK
Notification Date: 07/08/2010
Notification Time: 16:35 [ET]
Event Date: 07/08/2010
Event Time: 14:33 [EDT]
Last Update Date: 07/08/2010
Emergency Class: NON EMERGENCY
10 CFR Section:
74.57 - ALARM RESOLUTION
Person (Organization):
MALCOLM WIDMANN (R2DO)
DAVID PSTRAK (NMSS)
FUELS OUO GRP EMAIL
Event Text
MATERIAL CONTROL AND ACCOUNTABILITY (MC&A) ALARM ACTUATION

"10 CFR 74.57 (f) (2) requires notification within 24 hours that an MC&A alarm resolution procedure has been initiated. The input minus output value exceeded the limit in the Solvent Extraction Area of Building 333. The input minus output value has been resolved. There is no indication that a material loss has occurred.

"There were no actual or potential safety consequences to workers, the public, or the environment.

"An input minus output process monitoring material balance was calculated for the Building 333 Solvent Extraction Area as specified by applicable procedures and requirements. The input minus output value exceeded the limit. An investigation was initiated."

The licensee has notified the NRC Resident Inspector. Similar EN #46064.