Skip to main content

Event Notification Report for June 28, 2010

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
06/27/2010 - 06/28/2010

EVENT NUMBERS
460494605046055

General Information or Other
Event Number: 46049
Rep Org: SOUTH CAROLINA DEPARTMENT OF HEALTH
Licensee: F&ME CONSULTANTS
Region: 1
City: NORTH CHARLESTON   State: SC
County:
License #: SC-293
Agreement: Y
Docket:
NRC Notified By: MELINDA BRADSHAW
HQ OPS Officer: ERIC SIMPSON
Notification Date: 06/28/2010
Notification Time: 10:58 [ET]
Event Date: 06/28/2010
Event Time: 08:00 [EDT]
Last Update Date: 06/28/2010
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
JAMES DWYER (R1DO)
ANGELA MCINTOSH (FSME)
ILTAB via email
Event Text
AGREEMENT STATE - MOISTURE DENSITY GAUGE STOLEN FROM JOB SITE

The following information was received from the State of South Carolina via fax:

"The South Carolina Department of Health and Environmental Control (SC DHEC) was notified on Monday, June 28, 2010 at 8:00 a.m. that a Humboldt Model 5001 B, SN 2508, portable moisture density gauge had been stolen from a job site storage unit in North Charleston, SC. The gauge contained 11 milliCuries maximum of Cesium 137 and 44 milliCuries maximum of Americium 241:Be. [An] F&ME employee, notified the SC DHEC that a gauge technician arrived for work Monday morning and discovered that the job site storage trailer had been broken into. [The site RSO] was notified immediately and he in turn called local police and fire department personnel. He also notified SC DHEC of the occurrence. The RSO indicated that the trailer had been secured on Friday evening (June 25) with the gauge locked in its storage container in the locked storage cabinet within the trailer. No work was performed over the weekend. The theft was discovered, as outlined above, early Monday morning. There were a few other items stolen as well - a GPS unit and a computer. An inventory was still underway at the time of this notification. The local police responders were made well aware of what type of gauge this was and were in the process of filling out the police report. The RSO was advised to fax the police report to SC DHEC once he obtained it."

THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf


General Information or Other
Event Number: 46050
Rep Org: OK DEQ RAD MANAGEMENT
Licensee: STANDARD TESTING AND ENGINEERING COMPANY
Region: 4
City: TULSA   State: OK
County:
License #: OK-17054-03
Agreement: Y
Docket:
NRC Notified By: MIKE BRODERICK
HQ OPS Officer: ERIC SIMPSON
Notification Date: 06/28/2010
Notification Time: 17:23 [ET]
Event Date: 06/28/2010
Event Time: 08:00 [CDT]
Last Update Date: 07/01/2010
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
RICK DEESE (R4DO)
MARK THAGGARD (FSME)
ILTAB via email
Event Text
AGREEMENT STATE REPORT - STOLEN TROXLER GAUGE

The following report was received via email from the State of Oklahoma:

"On June 28, 2010, the Oklahoma Department of Environmental Quality (ODEQ) received notification from Standard Testing and Engineering Company (Standard) of Oklahoma City operating under license number OK-17054-03 that one of Standard's nuclear gauges was stolen from the home of an employee living in Tulsa, OK. The gauge is a Troxler Model 3411B moisture/density gauge, serial number 16968. The gauge contained a 0.30 GBq 137-Cs source serial number 506707 and a 1.48 GBq 241-Am source serial number 4712391. Standard stated that it is against company policy to store gauges at employee residences and that the employee has been terminated. It is unclear at this time if the gauge was properly stored within the gauge restraints that are installed in all Standard company vehicles.

"There is no reason to believe that this is anything other than a common theft. The licensee has notified local law enforcement. The ODEQ is notifying the FBI. The company has not issued a press release. ODEQ will seek to either issue a press release, or have the company issue a press release to help raise public awareness of the appearance of the gauge and the level of risk it poses, in case it is abandoned in a public place."

* * * UPDATE FROM MIKE BRODERICK TO JOE O'HARA VIA EMAIL AT 1724 ON 7/1/10 * * *

"The portable gauge reported stolen on June 28th at approximately 4:15 PM has been recovered. A citizen contacted a company that provides services to portable gauge users, and the company contacted Oklahoma DEQ and provided us with information to contact the citizen. We [OK DEQ] placed the licensee in contact with the person who had found the gauge, and the gauge was recovered at about 11 AM on June 30. The gauge appears to be undamaged.

Notified R4DO(Lantz), FSME EO(Luehman), and ILTAB via email


THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf


General Information or Other
Event Number: 46055
Rep Org: WISCONSIN RADIATION PROTECTION
Licensee: TETRA TECH, INC
Region: 3
City: JEFFERSON   State: WI
County:
License #: 073-1165-01
Agreement: Y
Docket:
NRC Notified By: KURT PEDERSEN
HQ OPS Officer: ERIC SIMPSON
Notification Date: 06/29/2010
Notification Time: 17:20 [ET]
Event Date: 06/28/2010
Event Time: 20:35 [CDT]
Last Update Date: 06/29/2010
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
ROBERT DALEY (R3DO)
CHRISTIAN EINBERG (FSME)
Event Text
AGREEMENT STATE REPORT - MOISTURE DENSITY GAUGE DESTROYED IN FIRE

The following report was received via fax from the State of Wisconsin:

"On June 28, 2010 at 20:35 the Department of Health Services (DHS) on-call State Radiological Coordinator (SRC) was informed that there had been a fire involving two trailers at the Dodge Concrete Ready Mix plant, W6298 US Hwy 18, Jefferson, WI. One of the trailers contained a Troxler 3440 portable moisture density gauge owned by Tetra Tech, a Wisconsin Radioactive Materials Licensee who was performing licensed activities at the concrete plant. The gauge contains a maximum of 9 milliCuries of Cesium-137 and 44 milliCuries of Americium-241:Beryllium as radioactive sealed sources. The original call to the DHS 24 hour emergency hotline was made by the Tetra Tech Radiation Safety Officer (RSO).

"The SRC subsequently received a page from the Wisconsin Emergency Management (WEM) Duty Officer at 20:45. The Duty Officer explained to the SRC that he had been informed of a fire in Jefferson, (WI) involving two burning trailers involving radioactive material. The SRC informed the duty officer that DHS intended on following up on the incident and would provide additional information.

"The SRC then contacted the licensee RSO. The RSO was at the scene of the fire interacting with the fire department. He (RSO) indicated that a fire had consumed two of their job trailers at Dodge Ready Mix and that one trailer contained a portable gauge which housed both a Cs-137 and an Am-241/Be radioactive source. The RSO indicated that radiation surveys around the trailer indicated radiation levels of less than 1 mR/hr around the burned trailer containing the gauge. After the RSO proposed his course of action to the SRC, they agreed that it was unsafe to attempt to extract the gauge from the trailer in the dark. The RSO cordoned off the trailer with yellow "Caution-Do Not Enter" tape pending an attempt to extract the gauge the following morning. All of the licensee's proper radiation postings and equipment were also destroyed in the fire. All postings and labels on the gauge transport container and the gauge itself were destroyed. DHS informed the RSO that they would arrive at the scene of the fire the next morning to supervise the extraction and provide technical radiation safety support.

"DHS investigators arrived at Dodge Ready Mix in Jefferson, Wl at 09:30. The Tetra Tech RSO and Authorized Users (AU) were present. Both trailers were completely destroyed by the fire and the gauge housing, transport case and associated equipment were melted together and fused to the trailer floor. The melted plastic, gauge and trailer housing had to be removed as a block. The maximum radiation level was ~8 mR/hr near contact with the Cs-137 shielding, which appeared to be intact. The radiation levels indicated that the shielding for both sources had retained its integrity. Contamination wipes were taken on the source rod, source shielding and the source exit point. No evidence of contamination was found. The DHS investigators were informed that the fire department had moved the trailers away from the site garage to reduce the risk of the fire spreading. All debris, trailers and trailer sites were surveyed. No elevated radiation levels were found. These surveys gave the DHS investigators and RSO confidence that the source remained in the fully shielded position.

"After consulting with Troxler, the gauge manufacturer, the RSO decided to remove the melted plastic and debris from the gauge remnants so it could be transported and shipped back to Troxler in a standard transport case. The licensee succeeded in removing the debris and melted plastic and at 12:45 was able to package the gauge in the Type-A transport container for return to their office in Wausau. The gauge was to be leak tested prior to shipment to Troxler for disposal. All debris removed from the gauge and the gauge itself was surveyed for contamination and radiation levels. The maximum radiation level remained at ~8 mR/hr and no evidence of contamination was found. The transport index was consistent with what the RSO typically finds with an intact gauge."

Event Report ID: WI100011