Skip to main content

Event Notification Report for March 19, 2010

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
03/18/2010 - 03/19/2010

EVENT NUMBERS
45778457804578145782

General Information or Other
Event Number: 45778
Rep Org: TEXAS DEPARTMENT OF HEALTH
Licensee: STRUCTURAL METALS, INC.
Region: 4
City: SEGUIN   State: TX
County:
License #: LO-2188
Agreement: Y
Docket:
NRC Notified By: ANNIE BACKHAUS
HQ OPS Officer: DONALD NORWOOD
Notification Date: 03/19/2010
Notification Time: 12:50 [ET]
Event Date: 03/19/2010
Event Time: 00:00 [CDT]
Last Update Date: 03/22/2010
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
WAYNE WALKER (R4DO)
ANGELA MCINTOSH (FSME)
Event Text
AGREEMENT STATE REPORT - STUCK SHUTTER ON FIXED PROCESS GAUGE

The following information was received via E-mail:

"On March 19, 2010, at 1130 hours, the Agency [Texas Department of State Health Services] received a telephone call from the licensee [Structural Metals, Inc. DBA: CMC Steel Texas] stating that the shutter on one of their gauges was stuck. The gauge houses a Cobalt (Co)-60 source. The shutter stuck in the open position, [which is] the normal operating position. Dose rates taken in the area were normal, and the licensee has contacted a repair company to have the shutter fixed sometime next week. The licensee will not be using the gauge until it is fixed, and has agreed to update the Agency as information is received.

"Texas Incident #: I-8725"

* * * UPDATE ON 3/22/10 AT 1442 FROM TEXAS (ROBERT FREE) TO HUFFMAN * * *

The following information was received from the State of Texas via e-mail:

"A Co-60 gauge [was reported by the licensee to have been] damaged by molten steel during a pouring operation. The area was secured from personnel entry until the licensee authorized to conduct recovery operations arrives on site today to begin recovery operation. No model or serial number is available at this time. [The Texas Dept. of Health Radiation Branch] will provide an update as more complete information is available."

* * * UPDATE ON 3/22/10 AT 1744 FROM TEXAS (ROBERT FREE) TO HUFFMAN * * *

The following information was received from the State of Texas via e-mail:

"The event description should indicate that there was molten metal splashed or poured over the gauge. The gauge shutter mechanism remained open. The company, Structural Metals (CMC), did not know the status of the gauge until today. The gauge was recovered by a licensed contractor and the shielding was found to be intact. The only damage to the gauge was the mechanism used to open and close the shutter. The gauge will be repaired or replaced."

R4DO (Deese) and FSME EO (Luehman) notified.


Other Nuclear Material
Event Number: 45780
Rep Org: SOURCE PRODUCTION & EQUIPMENT CO.
Licensee: SOURCE PRODUCTION & EQUIPMENT CO.
Region: 4
City: ST ROSE   State: LA
County:
License #: NRC GENERAL
Agreement: Y
Docket:
NRC Notified By: KELLEY RICHARDT
HQ OPS Officer: BILL HUFFMAN
Notification Date: 03/19/2010
Notification Time: 15:15 [ET]
Event Date: 03/19/2010
Event Time: 00:00 [CDT]
Last Update Date: 03/19/2010
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
WAYNE WALKER (R4DO)
JIM LUEHMAN (FSME)
LINDA GERSEY (R4)
STEPHEN BAKER (IP)
ILTAB VIA E-MAIL
Event Text
SELENIUM-75 SOURCE MISSING FROM SHIPMENT

A representative of Source Production & Equipment Company (SPEC) notified the NRC that an 8 curie Selenium-75 source was missing from a shipment of 6 sources received at SPEC sometime around March 12, 2010. The shipment of 6 total special form (solid) Se-75 sources were shipped from Gilligan Engineering in Prudoe, England on March 9, 2010 and 5 of the 6 sources were received by SPEC. The licensee considers the source missing at this time but has not exhausted its search.

The State of Louisiana has been notified. In addition, SPEC has contacted the shipment carrier to investigate the shipment tracking and determine if the single missing source might have been misdirected. The shipment was believed to have entered the US in Memphis, TN via air freight from England.

THIS MATERIAL EVENT CONTAINS A "CATEGORY 3" LEVEL OF RADIOACTIVE MATERIAL

Category 3 sources, if not safely managed or securely protected, could cause permanent injury to a person who handled them, or were otherwise in contact with them, for some hours. It could possibly - although it is unlikely - be fatal to be close to this amount of unshielded radioactive material for a period of days to weeks. These sources are typically used in practices such as fixed industrial gauges involving high activity sources (for example: level gauges, dredger gauges, conveyor gauges and spinning pipe gauges) and well logging. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf

This source is not amongst those sources or devices identified by the IAEA Code of Conduct for the Safety & Security of Radioactive Sources to be of concern from a radiological standpoint. Therefore is it being categorized as a less than Category 3 source


General Information or Other
Event Number: 45781
Rep Org: TEXAS DEPARTMENT OF HEALTH
Licensee: PROTECHNICS
Region: 4
City: ALICE   State: TX
County: JIM WELLS
License #: 03835
Agreement: Y
Docket:
NRC Notified By: ART TUCKER
HQ OPS Officer: VINCE KLCO
Notification Date: 03/20/2010
Notification Time: 01:35 [ET]
Event Date: 03/19/2010
Event Time: 23:20 [CDT]
Last Update Date: 03/26/2010
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
WAYNE WALKER (R4DO)
JIM LUEHMAN (FSME)
LANCE ENGLISH (ILTA)
MEXICO VIA FAX
Event Text
AGREEMENT STATE REPORT - THEFT OF LICENSED MATERIALS

The following information was received by e-mail:

"On March 19, 2010 at 2350 hours, the Agency [Texas Department of State Health Services-Radiation Branch] was notified by the licensee's Radiation Safety Officer (RSO) that 120 milliCuries of Iridium (Ir)-192 was stolen from one of their trucks parked at a Wal-Mart parking lot in Alice, Texas at about 2320 hours. The Ir-192 was contained in six, 20 milliliter vials each containing 20 millicuries (15 grams) of Ir-192 in the form of zero wash [isotope tracer]. Each vial was placed into a labeled lead pig and each pig was then shrink wrapped. The six pigs were then placed into a zip lock bag. The zip lock bag was placed into a tool box in the back of the pick up truck. The licensee stated that the employee had stopped at the Wal-Mart on their way to a job site in south Texas. The RSO stated that the tool box was not locked and other items were stolen from the tool box. The tool box did not have any labeling on it. The RSO stated that the employee did not perform a radiation survey of the pigs, but he estimated the dose rate to be about 100 millirem per hour on the outside of the tool box. Local law enforcement was notified of the theft. Additional information will be provided as it is received."

Texas Incident Number: I-8730

* * * UPDATE FROM ART TUCKER (VIA EMAIL) TO HOWIE CROUCH @ 1017 EDT ON 3/26/10 * * *

"At 1730 on March 24, 2010, Alice police department notified the Agency that they had information regarding the location of the radioactive material. The material was subsequently found at a private residence. The material was inspected, surveyed, and returned to the licensee. The shrink wrap around each of the lead pigs was still intact, indicating the glass vials containing the radioactive materials had not been accessed. The Agency is performing dose estimates for the individuals who lived in the home."

Notified R4DO (Deese), FSME EO (McIntosh), and FSME (Mauer). Notified ILTAB via email and Mexico via fax.

THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf

This source is not amongst those sources or devices identified by the IAEA Code of Conduct for the Safety & Security of Radioactive Sources to be of concern from a radiological standpoint. Therefore is it being categorized as a less than Category 3 source


General Information or Other
Event Number: 45782
Rep Org: TEXAS DEPARTMENT OF HEALTH
Licensee: WEATHERFORD US LP
Region: 4
City: BENBROOK   State: TX
County:
License #: L-00747
Agreement: Y
Docket:
NRC Notified By: BOB FREE
HQ OPS Officer: BILL HUFFMAN
Notification Date: 03/22/2010
Notification Time: 17:36 [ET]
Event Date: 03/19/2010
Event Time: 00:00 [CDT]
Last Update Date: 04/22/2010
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
RICK DEESE (R4DO)
JIM LUEHMAN (FSME)
Event Text
AGREEMENT STATE REPORT - WELL LOGGING TOOL EJECTED DURING WELL BLOW-OUT

The following information was received from the State of Texas via e-mail:

"Weatherford personnel were logging a well in Howard County, Texas when a blow out occurred. The logging tool was at 3500 feet when the tool and wireline were ejected from the well bore. The blow out preventer did not stop the tool and wireline from being ejected onto the surface. The crew evacuated the drilling rig due to the hazards associated with the high downhole pressure. Initially it was unknown whether the logging tool was still in the hole. A logging company manager conducted radiation surveys and found the tool, with the sources still in place near the logging truck. The sources were secured in their transport shields and returned to the company office for leak testing. At this point, there is no estimate of exposures to personnel at the well site."

Texas Report # I-8726

* * * UPDATE ON 04/22/2010 AT 1524 EDT FROM A. TUCKER TO R. ALEXANDER * * *

The following update was received from the State of Texas via e-mail:

"The licensee notified the Agency [Texas Department of State Health Services] that leak test results on the cesium and the americium-beryllium sources were satisfactory. The licensee stated that a visual examination of the sources did not find any physical damage."

Notified R4DO (J. Whitten) and FSME EO (C. Einberg).