Event Notification Report for December 30, 2009
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
12/29/2009 - 12/30/2009
EVENT NUMBERS
4560245597455984559945600
Other Nuclear Material
Event Number: 45602
Rep Org: DEPARTMENT OF VETERANS AFFAIRS
Licensee: RICHARD L. ROUDEBUSH VA MEDICAL CENTER
Region: 3
City: INDIANAPOLIS State: IN
County:
License #: 03-23853-01VA
Agreement: N
Docket:
NRC Notified By: THOMAS HUSTON
HQ OPS Officer: PETE SNYDER
Licensee: RICHARD L. ROUDEBUSH VA MEDICAL CENTER
Region: 3
City: INDIANAPOLIS State: IN
County:
License #: 03-23853-01VA
Agreement: N
Docket:
NRC Notified By: THOMAS HUSTON
HQ OPS Officer: PETE SNYDER
Notification Date: 12/31/2009
Notification Time: 12:18 [ET]
Event Date: 12/30/2009
Event Time: 00:00 [EST]
Last Update Date: 12/31/2009
Notification Time: 12:18 [ET]
Event Date: 12/30/2009
Event Time: 00:00 [EST]
Last Update Date: 12/31/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
35.3045(a)(1) - DOSE <> PRESCRIBED DOSAGE
10 CFR Section:
35.3045(a)(1) - DOSE <> PRESCRIBED DOSAGE
Person (Organization):
JOHN GIESSNER (R3DO)
GLENDA VILLAMAR (FSME)
JOHN GIESSNER (R3DO)
GLENDA VILLAMAR (FSME)
UNDERDOSE TO PATIENT
The Richard L. Roudebush VA Medical Center holds VHA Permit Number 13-00694-03 under the VA's Master Material License (NRC License Number 03-23853-01VA).
"For a patient treatment on December 30, 2009, involving Yttrium-90 microspheres, the medical center discovered (on same date) that the total activity delivered to the treatment site was less than 80% of the total activity documented in the written directive.
"The medical event was discovered when a waste container, which contained used catheters, lines, gloves, tongs, tape, etc., from the treatment were assayed. The waste materials indicated a higher than expected residual activity equal to about 25 percent of the activity that was in the source vial prior to treatment. Examination of the waste materials revealed that nearly all of the residual activity was distributed somewhat uniformly along the length of the approximately 100 cm microcatheter tubing.
"The current estimate is that about 47.03 millicuries were delivered to the patient, and 15.67 millicuries were in the wastes. The prescribed activity was 63.2 millicuries. Therefore, the patient was under-dosed by about 25.6%. Because this deviation exceeds 20%, a medical event is considered to have occurred per 10 CFR 35.3045(a)(1).
"Although a lower-than-intended activity was administered, the permittee estimates that the absorbed dose to the target organ was around 109 gray and was within the therapeutic target range of 100 to 150 gray. Therefore, no adverse biological effects to the patient are expected."
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.test
The Richard L. Roudebush VA Medical Center holds VHA Permit Number 13-00694-03 under the VA's Master Material License (NRC License Number 03-23853-01VA).
"For a patient treatment on December 30, 2009, involving Yttrium-90 microspheres, the medical center discovered (on same date) that the total activity delivered to the treatment site was less than 80% of the total activity documented in the written directive.
"The medical event was discovered when a waste container, which contained used catheters, lines, gloves, tongs, tape, etc., from the treatment were assayed. The waste materials indicated a higher than expected residual activity equal to about 25 percent of the activity that was in the source vial prior to treatment. Examination of the waste materials revealed that nearly all of the residual activity was distributed somewhat uniformly along the length of the approximately 100 cm microcatheter tubing.
"The current estimate is that about 47.03 millicuries were delivered to the patient, and 15.67 millicuries were in the wastes. The prescribed activity was 63.2 millicuries. Therefore, the patient was under-dosed by about 25.6%. Because this deviation exceeds 20%, a medical event is considered to have occurred per 10 CFR 35.3045(a)(1).
"Although a lower-than-intended activity was administered, the permittee estimates that the absorbed dose to the target organ was around 109 gray and was within the therapeutic target range of 100 to 150 gray. Therefore, no adverse biological effects to the patient are expected."
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.test
Power Reactor
Event Number: 45597
Facility: GINNA
Region: 1 State: NY
Unit: [1] [] []
RX Type: [1] W-2-LP
NRC Notified By: DANIEL DEAN
HQ OPS Officer: JOHN KNOKE
Region: 1 State: NY
Unit: [1] [] []
RX Type: [1] W-2-LP
NRC Notified By: DANIEL DEAN
HQ OPS Officer: JOHN KNOKE
Notification Date: 12/30/2009
Notification Time: 08:24 [ET]
Event Date: 12/30/2009
Event Time: 04:37 [EST]
Last Update Date: 12/30/2009
Notification Time: 08:24 [ET]
Event Date: 12/30/2009
Event Time: 04:37 [EST]
Last Update Date: 12/30/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL
Person (Organization):
LAWRENCE DOERFLEIN (R1DO)
LAWRENCE DOERFLEIN (R1DO)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | A/R | Y | 100 | Power Operation | 0 | Hot Standby |
AUTOMATIC REACTOR TRIP DUE TO TURBINE STOP VALVES CLOSING
"At 0437 hours [the] Turbine Stop Valves closed causing an automatic Reactor Trip. Auxiliary Feedwater Pumps automatically started as expected during the transient and operated normally. All control rods inserted on the reactor trip. Reactor Coolant System temperature and pressure are stable at 547 degrees and 2235 psig. The cause of the Turbine Stop Valve closure is under investigation."
The pressurizer relief and safety valves did not lift. Decay heat is being removed via the Auxiliary Feedwater Pumps and the Atmospheric Relief Valves. There is no primary to secondary leakage in the steam generators. Electrical lineup is normal, and the EDG's are available if required.
The licensee has notified the State and the NRC Resident Inspector
"At 0437 hours [the] Turbine Stop Valves closed causing an automatic Reactor Trip. Auxiliary Feedwater Pumps automatically started as expected during the transient and operated normally. All control rods inserted on the reactor trip. Reactor Coolant System temperature and pressure are stable at 547 degrees and 2235 psig. The cause of the Turbine Stop Valve closure is under investigation."
The pressurizer relief and safety valves did not lift. Decay heat is being removed via the Auxiliary Feedwater Pumps and the Atmospheric Relief Valves. There is no primary to secondary leakage in the steam generators. Electrical lineup is normal, and the EDG's are available if required.
The licensee has notified the State and the NRC Resident Inspector
Power Reactor
Event Number: 45598
Facility: PALO VERDE
Region: 4 State: AZ
Unit: [1] [2] [3]
RX Type: [1] CE,[2] CE,[3] CE
NRC Notified By: BRAD EKLUND
HQ OPS Officer: CHARLES TEAL
Region: 4 State: AZ
Unit: [1] [2] [3]
RX Type: [1] CE,[2] CE,[3] CE
NRC Notified By: BRAD EKLUND
HQ OPS Officer: CHARLES TEAL
Notification Date: 12/30/2009
Notification Time: 14:55 [ET]
Event Date: 12/30/2009
Event Time: 12:03 [MST]
Last Update Date: 12/30/2009
Notification Time: 14:55 [ET]
Event Date: 12/30/2009
Event Time: 12:03 [MST]
Last Update Date: 12/30/2009
Emergency Class: UNUSUAL EVENT
10 CFR Section:
50.72(a) (1) (i) - EMERGENCY DECLARED
10 CFR Section:
50.72(a) (1) (i) - EMERGENCY DECLARED
Person (Organization):
THOMAS FARNHOLTZ (R4DO)
JEFF GRANT (IRD)
ERIC LEEDS (NRR)
AUSTIN (FEMA)
MICHAEL ENSER (DHS)
THOMAS FARNHOLTZ (R4DO)
JEFF GRANT (IRD)
ERIC LEEDS (NRR)
AUSTIN (FEMA)
MICHAEL ENSER (DHS)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
| 3 | N | Y | 100 | Power Operation | 100 | Power Operation |
UNUSUAL EVENT DUE TO EARTHQUAKE
"The following event description is based on information currently available. If through subsequent reviews of this event, additional information is identified that is pertinent to this event or alters the information being provided at this time, a follow-up notification will be made via the ENS or under the reporting requirements of 10CFR50.73.
"An Event Classification of Unusual Event (HU1.1) was declared at 12:03 MST for the PVNGS (Palo Verde Nuclear Generating Station) site because of an earthquake that originated in Baja Mexico location 32.467 N, 115.195 W at 10:48:57 local time. Per the USGS (United States Geologic Survey) website, the magnitude of the earthquake 5.8 on the Richter scale. Initial walk downs of plant equipment and review of plant parameters have found no unusual conditions or damage to plant equipment. There was no automatic initiation of the Reactor Protection System or Emergency Safety Function System and none were required. The units are all at 100 percent power and all offsite power supplies are available.
"The earthquake didn't register on plant seismic monitoring equipment, but was felt by plant personnel."
* * * UPDATE FROM BRIESE TO TEAL AT 1722 ON 12/30/2009 * * *
"The Notification of Unusual event classification was terminated at 15:15 MST on 12/30/2009 after completion of walk downs of the protected area, ISFSI, cooling towers, switchyard, Station Blackout Generators and water reclamation with no equipment issues being found. "
Notified R4DO (Farnholtz), NRR EO (Evans), IRD (McDermott), FEMA, DHS
"The following event description is based on information currently available. If through subsequent reviews of this event, additional information is identified that is pertinent to this event or alters the information being provided at this time, a follow-up notification will be made via the ENS or under the reporting requirements of 10CFR50.73.
"An Event Classification of Unusual Event (HU1.1) was declared at 12:03 MST for the PVNGS (Palo Verde Nuclear Generating Station) site because of an earthquake that originated in Baja Mexico location 32.467 N, 115.195 W at 10:48:57 local time. Per the USGS (United States Geologic Survey) website, the magnitude of the earthquake 5.8 on the Richter scale. Initial walk downs of plant equipment and review of plant parameters have found no unusual conditions or damage to plant equipment. There was no automatic initiation of the Reactor Protection System or Emergency Safety Function System and none were required. The units are all at 100 percent power and all offsite power supplies are available.
"The earthquake didn't register on plant seismic monitoring equipment, but was felt by plant personnel."
* * * UPDATE FROM BRIESE TO TEAL AT 1722 ON 12/30/2009 * * *
"The Notification of Unusual event classification was terminated at 15:15 MST on 12/30/2009 after completion of walk downs of the protected area, ISFSI, cooling towers, switchyard, Station Blackout Generators and water reclamation with no equipment issues being found. "
Notified R4DO (Farnholtz), NRR EO (Evans), IRD (McDermott), FEMA, DHS
General Information or Other
Event Number: 45599
Rep Org: WA DIVISION OF RADIATION PROTECTION
Licensee: GEORGIA PACIFIC CONSUMER DIVISION
Region: 4
City: CAMAS State: WA
County:
License #: WN-I0228-1
Agreement: Y
Docket:
NRC Notified By: BRANDIN KETTER
HQ OPS Officer: CHARLES TEAL
Licensee: GEORGIA PACIFIC CONSUMER DIVISION
Region: 4
City: CAMAS State: WA
County:
License #: WN-I0228-1
Agreement: Y
Docket:
NRC Notified By: BRANDIN KETTER
HQ OPS Officer: CHARLES TEAL
Notification Date: 12/30/2009
Notification Time: 19:02 [ET]
Event Date: 12/30/2009
Event Time: 00:00 [PST]
Last Update Date: 03/01/2010
Notification Time: 19:02 [ET]
Event Date: 12/30/2009
Event Time: 00:00 [PST]
Last Update Date: 03/01/2010
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
THOMAS FARNHOLTZ (R4DO)
CHRISTEPHER MCKENNEY (FSME)
THOMAS FARNHOLTZ (R4DO)
CHRISTEPHER MCKENNEY (FSME)
AGREEMENT STATE - STUCK SHUTTER ON FIXED DENSITY METER
The following was received via email:
"A fixed gauge licensee operating a paper mill in Camas, Washington, reported that the shutter mechanism of an Ohmart Vega fixed gauge, Model Number SH-F1B-0, containing a 100 mCi sealed source of Cesium 137 failed to close during a routine six-month shutter check.
"The Radiation Safety Officer reported the gauge is mounted on a vertical section of six-inch piping and is still functioning correctly as a density meter. The device is not part of any lockout or confined space entry permit and there is currently no safety hazard potential for exposure to radiation associated with the failure of the shutter mechanism.
"The environment where the gauge is mounted is susceptible to messy process conditions which allows water and lime-mud to accumulate on the fixed gauge. This appears to have contributed to the failure of the shutter mechanism. The manufacturer's representative was called by the licensee and has scheduled a visit to the facility to make corrective repairs."
Report #: WA090097
* * * UPDATE FROM BRANDIN KETTER TO HOWIE CROUCH VIA EMAIL ON 3/1/10 @ 1526 HRS. EST * * *
"On February 25, 2010, service representatives from Ohmart Vega replaced the shutter mechanism with a new shutter closing this incident."
Notified R4DO (Cain) and FSME EO (McIntosh).
The following was received via email:
"A fixed gauge licensee operating a paper mill in Camas, Washington, reported that the shutter mechanism of an Ohmart Vega fixed gauge, Model Number SH-F1B-0, containing a 100 mCi sealed source of Cesium 137 failed to close during a routine six-month shutter check.
"The Radiation Safety Officer reported the gauge is mounted on a vertical section of six-inch piping and is still functioning correctly as a density meter. The device is not part of any lockout or confined space entry permit and there is currently no safety hazard potential for exposure to radiation associated with the failure of the shutter mechanism.
"The environment where the gauge is mounted is susceptible to messy process conditions which allows water and lime-mud to accumulate on the fixed gauge. This appears to have contributed to the failure of the shutter mechanism. The manufacturer's representative was called by the licensee and has scheduled a visit to the facility to make corrective repairs."
Report #: WA090097
* * * UPDATE FROM BRANDIN KETTER TO HOWIE CROUCH VIA EMAIL ON 3/1/10 @ 1526 HRS. EST * * *
"On February 25, 2010, service representatives from Ohmart Vega replaced the shutter mechanism with a new shutter closing this incident."
Notified R4DO (Cain) and FSME EO (McIntosh).
Power Reactor
Event Number: 45600
Facility: CATAWBA
Region: 2 State: SC
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: JOHN GATES
HQ OPS Officer: CHARLES TEAL
Region: 2 State: SC
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: JOHN GATES
HQ OPS Officer: CHARLES TEAL
Notification Date: 12/30/2009
Notification Time: 22:45 [ET]
Event Date: 12/30/2009
Event Time: 22:10 [EST]
Last Update Date: 12/30/2009
Notification Time: 22:45 [ET]
Event Date: 12/30/2009
Event Time: 22:10 [EST]
Last Update Date: 12/30/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
CHARLIE PAYNE (R2DO)
CHARLIE PAYNE (R2DO)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
OSHA CONTACTED DUE TO ON-SITE FATALITY
"A non-contaminated individual was transported by ambulance from the Catawba Nuclear Station parking lot to a local hospital due to a personal illness. The individual was pronounced dead at the hospital. Catawba Nuclear Station is notifying [Occupation Safety Health Administration] OSHA of an on-site fatality."
Licensee has notified the NRC Resident Inspector.
"A non-contaminated individual was transported by ambulance from the Catawba Nuclear Station parking lot to a local hospital due to a personal illness. The individual was pronounced dead at the hospital. Catawba Nuclear Station is notifying [Occupation Safety Health Administration] OSHA of an on-site fatality."
Licensee has notified the NRC Resident Inspector.