Skip to main content

Event Notification Report for December 16, 2009

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
12/15/2009 - 12/16/2009

EVENT NUMBERS
455754557645577455734563847791

Power Reactor
Event Number: 45575
Facility: PALO VERDE
Region: 4     State: AZ
Unit: [1] [2] [3]
RX Type: [1] CE,[2] CE,[3] CE
NRC Notified By: FARA ORESHACK
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 12/16/2009
Notification Time: 17:30 [ET]
Event Date: 12/16/2009
Event Time: 06:11 [MST]
Last Update Date: 12/16/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
26.719 - FITNESS FOR DUTY
Person (Organization):
JACK WHITTEN (R4DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
3 N Y 100 Power Operation 100 Power Operation
Event Text
FITNESS FOR DUTY - NON-LICENSED SUPERVISOR

A non-licensed supervisor had a confirmed positive for alcohol during a "for cause" fitness-for-duty test. The employee's access to the plant has been terminated. Contact the Headquarters Operations Officer for additional details.

The licensee notified the NRC Resident Inspector.


Power Reactor
Event Number: 45576
Facility: PALO VERDE
Region: 4     State: AZ
Unit: [1] [2] [3]
RX Type: [1] CE,[2] CE,[3] CE
NRC Notified By: FARA ORESHACK
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 12/16/2009
Notification Time: 17:30 [ET]
Event Date: 12/16/2009
Event Time: 10:39 [MST]
Last Update Date: 12/17/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
26.719 - FITNESS FOR DUTY
Person (Organization):
JACK WHITTEN (R4DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
3 N Y 100 Power Operation 100 Power Operation
Event Text
FITNESS FOR DUTY - LICENSED OPERATOR

A licensed operator supervisor had a confirmed positive for alcohol during a "for cause" test. The employee's access to the plant has been terminated. Contact the Headquarters Operations Officer for additional details.

The licensee notified the NRC Resident Inspector.

* * * UPDATE FROM ELKINTON TO ABRAMOVITZ AT 1637 ON 12/17/2009 * * *

The licensed operator was not a supervisor.

Notified the R4DO (Whitten) via e-mail.


Power Reactor
Event Number: 45577
Facility: SUMMER
Region: 2     State: SC
Unit: [1] [] []
RX Type: [1] W-3-LP
NRC Notified By: JASON WEATHERSBY
HQ OPS Officer: KARL DIEDERICH
Notification Date: 12/16/2009
Notification Time: 17:30 [ET]
Event Date: 12/16/2009
Event Time: 14:15 [EST]
Last Update Date: 12/16/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
CHARLIE PAYNE (R2DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 M/R Y 45 Power Operation 0 Hot Standby
Event Text
MANUAL REACTOR TRIP FOLLOWING A FAILURE OF THE STEAM DUMP SYSTEM

"VC Summer Nuclear Station (VCSNS) was performing a preplanned turbine shutdown in order to perform maintenance on a faulty turbine control valve. After the manual turbine trip, the steam dump system failed to operate and the crew manually tripped the reactor. The cause of the failure of the steam dump system is unknown, and is currently being investigated. Both motor driven Emergency Feedwater pumps were manually started at 40% Steam Generator Level. Preliminary review indicates all other primary and secondary systems responded as required. The plant is in mode 3 at normal RCS [Reactor Coolant System] pressure and temperature. Decay heat is being removed by dumping steam via the secondary [steam generator] power operated relief valves. The station will remain in mode 3 until repairs are complete. Estimated restart date has not been determined."

All rods fully inserted. There is no known primary to secondary leakage. Off site power supply configuration is normal. The turbine trip was performed at 45% power due to a stuck open turbine control valve.

The licensee has notified the NRC Resident Inspector and will notify state and local contacts.


General Information or Other
Event Number: 45573
Rep Org: TEXAS DEPARTMENT OF HEALTH
Licensee: H. H. HOLMES TESTING LABORATORY
Region: 3
City: WHEELING   State: IL
County:
License #: IL-01828-01
Agreement: Y
Docket:
NRC Notified By: ART TUCKER
HQ OPS Officer: KARL DIEDERICH
Notification Date: 12/16/2009
Notification Time: 10:45 [ET]
Event Date: 12/16/2009
Event Time: 00:00 [CST]
Last Update Date: 12/22/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
JACK WHITTEN (R4DO)
GLENDA VILLAMAR (FSME)
LANCE ENGLISH (ILTA)
CNSNS-MEXICO VIA FAX
Event Text
AGREEMENT STATE REPORT - STOLEN MOISTURE DENSITY GAUGE

The following report was received via e-mail:

"On December 16, 2009, at 0729 hours, the licensee notified the [Texas] agency that sometime during the previous night, a company truck containing a Humboldt model 5001 EZ moisture density gauge serial # 3566 was stolen from an employee's home. The gauge contains a 10 millicurie Cesium (Cs) -137 source and a 40 millicurie Americium-241 /Beryllium (Am/Be) source. Local law enforcement was notified and a report filed. The employee is on his way to the company's office to file a complete report. The [Texas] agency has notified the Texas Association of Pawnbrokers of the theft. The company is licensed in the State of Illinois (IL-01828-01) and operating in Texas under reciprocity. It is unknown at this time how the gauge was stored in the vehicle or the address where the vehicle was located when it was stolen. This [Texas] agency will supply additional information as it is obtained."

* * * UPDATE FROM A. TUCKER TO P. SNYDER AT 0926 ON 12/22/09 * * *

The following report was received via e-mail:

"On December 22, 2009, at 0809 hours, the license notified the agency that on the evening of December 21, 2009, the stolen truck was located in an impound yard. The gauge was still on the truck. The gauge was inspected and was undamaged. The gauge has been returned to storage. No additional information is available at this time. The licensee stated that a written report will be provided within the next week."

Notified R4DO (Walker), FSME (Villamar), and ILTAB (e-mail).

The Texas agency notified the State of Illinois. Texas Incident Number I-8693.

THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf


Power Reactor
Event Number: 45638
Facility: SUSQUEHANNA
Region: 1     State: PA
Unit: [1] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: JOHN PACIOTTI
HQ OPS Officer: VINCE KLCO
Notification Date: 01/20/2010
Notification Time: 12:20 [ET]
Event Date: 12/16/2009
Event Time: 09:00 [EST]
Last Update Date: 01/20/2010
Emergency Class: NON EMERGENCY
10 CFR Section:
26.719 - FITNESS FOR DUTY
Person (Organization):
RONALD BELLAMY (R1DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 94 Power Operation 94 Power Operation
2 N Y 94 Power Operation 94 Power Operation
Event Text
POSSESSION OF ALCOHOLIC BEVERAGE IN PROTECTED AREA

"At approximately 0900 on December 16, 2009, a PPL employee, located within the Susquehanna protected area, received a gift package from a vendor that contained a bottle of an alcoholic beverage. The individual immediately notified his supervision and Susquehanna Security personnel who took possession of the bottle. The bottle was still sealed with the original seal. The NRC [Resident Inspector] and Regional Security Inspectors were informed on the day of the event.

"The individual who received the package was a non-licensed employee.

"This event was originally not recognized as being reportable as a 24 hour call."


!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Non-Agreement State
Event Number: 47791
Rep Org: US ARMY
Licensee: US ARMY
Region: 3
City: WARREN   State: MI
County:
License #: 21-32838-01
Agreement: N
Docket:
NRC Notified By: THOMAS GIZICKI
HQ OPS Officer: CHARLES TEAL
Notification Date: 03/30/2012
Notification Time: 15:31 [ET]
Event Date: 12/16/2009
Event Time: 00:00 [EDT]
Last Update Date: 04/05/2012
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2201(a)(1)(i) - LOST/STOLEN LNM>1000X
Person (Organization):
CHRISTOPHER NEWPORT (R1DO)
ANGELA MCINTOSH (FSME)
BILLY DICKSON (R3DO)
Event Text
MISSING CHEMICAL AGENT DETECTOR

When returning from deployment a Virginia National Guard unit discovered that they had lost a M43A1 Chemical Detector containing 250 uCi of Am-241. The unit searched the facility as well as a storage warehouse located in Richmond, VA for the device, but they were unable to locate it.

* * * RETRACTION FROM THOMAS GIZICKI TO VINCE KLCO ON 4/5/2012 AT 1201 EDT * * *

Retraction due to the detector found in the same location in a different Army unit.

Notified the R1DO (Caruso), R3DO (Bloomer) and the FSME (McIntosh).

THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf

This source is not amongst those sources or devices identified by the IAEA Code of Conduct for the Safety & Security of Radioactive Sources to be of concern from a radiological standpoint. Therefore is it being categorized as a less than Category 3 source