Event Notification Report for December 08, 2009
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
12/07/2009 - 12/08/2009
General Information or Other
Event Number: 45548
Rep Org: ENGINE SYSTEMS, INC.
Licensee: ENGINE SYSTEMS, INC.
Region: 1
City: ROCKY MOUNT State: NC
County:
License #:
Agreement: Y
Docket:
NRC Notified By: PAUL STEPANTSCHENKO
HQ OPS Officer: DAN LIVERMORE
Licensee: ENGINE SYSTEMS, INC.
Region: 1
City: ROCKY MOUNT State: NC
County:
License #:
Agreement: Y
Docket:
NRC Notified By: PAUL STEPANTSCHENKO
HQ OPS Officer: DAN LIVERMORE
Notification Date: 12/08/2009
Notification Time: 11:22 [ET]
Event Date: 12/08/2009
Event Time: 00:00 [EST]
Last Update Date: 12/08/2009
Notification Time: 11:22 [ET]
Event Date: 12/08/2009
Event Time: 00:00 [EST]
Last Update Date: 12/08/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
21.21 - UNSPECIFIED PARAGRAPH
10 CFR Section:
21.21 - UNSPECIFIED PARAGRAPH
Person (Organization):
REBECCA NEASE (R2DO)
BLAIR SPITZBERG (R4DO)
PART 21 COORDINATOR (NRR)
REBECCA NEASE (R2DO)
BLAIR SPITZBERG (R4DO)
PART 21 COORDINATOR (NRR)
WOODWARD GOVERNOR SERVO FAILURE DUE TO SILVER SULFIDE CORROSION OF SURFACE MOUNT RESISTORS
"Woodward failure analysis report #85572-R001, dated 10/9/09, addressed two separate [model] PGPL remote servo failures. The failure analysis report discusses a silver sulfide corrosion issue with surface mount resistors used in the PGPL remote servo feedback transmitter circuitry. Woodward part number 9903-539 consists of a PGPL actuator and a remote servo. The PGPL actuator is mounted on the turbine's governor drive and the remote servo (Woodward part number 5296-044) is mounted at the steam valve. Hydraulic lines interconnect the PGPL to the remote servo. The PGPL actuator and remote servo was supplied by Engine Systems, Inc. (ESI) to the Callaway and Vogtle nuclear plants as part of a digital governor upgrade (Woodward 505 control) on their steam turbine generators. These are the only nuclear plants that use the P/N 9903-539 actuator remote servo assembly.
"LISTING OF WOODWARD PIN 9903-539 PGPL ACTUATORS WITH SUSPECT RESISTORS
"Serial Number Born Date Shipped to
12369963 Nov 2000 Callaway
13305595 July 2002 Callaway
13798414 May 2004 Vogtle
13798415 May 2004 Callaway
14141720 Feb 2005 Vogtle
14409400 Sep 2005 Vogtle
"Note: Serial numbers 12369963 and 13798414 recently had the feedback board replaced during the failure analysis; these require no further corrective action."
"Woodward failure analysis report #85572-R001, dated 10/9/09, addressed two separate [model] PGPL remote servo failures. The failure analysis report discusses a silver sulfide corrosion issue with surface mount resistors used in the PGPL remote servo feedback transmitter circuitry. Woodward part number 9903-539 consists of a PGPL actuator and a remote servo. The PGPL actuator is mounted on the turbine's governor drive and the remote servo (Woodward part number 5296-044) is mounted at the steam valve. Hydraulic lines interconnect the PGPL to the remote servo. The PGPL actuator and remote servo was supplied by Engine Systems, Inc. (ESI) to the Callaway and Vogtle nuclear plants as part of a digital governor upgrade (Woodward 505 control) on their steam turbine generators. These are the only nuclear plants that use the P/N 9903-539 actuator remote servo assembly.
"LISTING OF WOODWARD PIN 9903-539 PGPL ACTUATORS WITH SUSPECT RESISTORS
"Serial Number Born Date Shipped to
12369963 Nov 2000 Callaway
13305595 July 2002 Callaway
13798414 May 2004 Vogtle
13798415 May 2004 Callaway
14141720 Feb 2005 Vogtle
14409400 Sep 2005 Vogtle
"Note: Serial numbers 12369963 and 13798414 recently had the feedback board replaced during the failure analysis; these require no further corrective action."
Power Reactor
Event Number: 45549
Facility: ARKANSAS NUCLEAR
Region: 4 State: AR
Unit: [] [2] []
RX Type: [1] B&W-L-LP,[2] CE
NRC Notified By: GREG HUDNALL
HQ OPS Officer: DAN LIVERMORE
Region: 4 State: AR
Unit: [] [2] []
RX Type: [1] B&W-L-LP,[2] CE
NRC Notified By: GREG HUDNALL
HQ OPS Officer: DAN LIVERMORE
Notification Date: 12/08/2009
Notification Time: 12:19 [ET]
Event Date: 12/08/2009
Event Time: 08:42 [CST]
Last Update Date: 12/08/2009
Notification Time: 12:19 [ET]
Event Date: 12/08/2009
Event Time: 08:42 [CST]
Last Update Date: 12/08/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
BLAIR SPITZBERG (R4DO)
BLAIR SPITZBERG (R4DO)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | M/R | Y | 100 | Power Operation | 0 | Hot Standby |
MANUAL REACTOR TRIP DUE TO LOW STEAM GENERATOR LEVEL CAUSED BY LOSS OF MAIN FEED WATER PUMP
"Arkansas Nuclear One - Unit 2 experienced a high temperature on the 'A' Main Feedwater Pump thrust bearing which required the pump to be manually tripped . Steam Generator levels lowered as a result of the Main Feedwater Pump trip to the point that operators initiated a manual reactor trip. The Emergency Feedwater System automatically actuated on low Steam Generator level as a result of the Steam Generator level transient.
"The manual reactor trip requires 4-Hr non-emergency notification IAW 10CFR 50.72(b)(2)(iv)(B).
"The automatic actuation of Emergency Feedwater requires 8-Hr non-emergency notification IAW 10CFR 50.72(b)(3)(iv)(A)."
All rods fully inserted. After the trip, decay heat was being removed using steam dumps to the condenser. Steam generator level was being maintained with the emergency feedwater pumps.
The licensee will notify the NRC Resident Inspector.
"Arkansas Nuclear One - Unit 2 experienced a high temperature on the 'A' Main Feedwater Pump thrust bearing which required the pump to be manually tripped . Steam Generator levels lowered as a result of the Main Feedwater Pump trip to the point that operators initiated a manual reactor trip. The Emergency Feedwater System automatically actuated on low Steam Generator level as a result of the Steam Generator level transient.
"The manual reactor trip requires 4-Hr non-emergency notification IAW 10CFR 50.72(b)(2)(iv)(B).
"The automatic actuation of Emergency Feedwater requires 8-Hr non-emergency notification IAW 10CFR 50.72(b)(3)(iv)(A)."
All rods fully inserted. After the trip, decay heat was being removed using steam dumps to the condenser. Steam generator level was being maintained with the emergency feedwater pumps.
The licensee will notify the NRC Resident Inspector.
Power Reactor
Event Number: 45550
Facility: DRESDEN
Region: 3 State: IL
Unit: [] [2] [3]
RX Type: [1] GE-1,[2] GE-3,[3] GE-3
NRC Notified By: FRANK WINTER
HQ OPS Officer: VINCE KLCO
Region: 3 State: IL
Unit: [] [2] [3]
RX Type: [1] GE-1,[2] GE-3,[3] GE-3
NRC Notified By: FRANK WINTER
HQ OPS Officer: VINCE KLCO
Notification Date: 12/08/2009
Notification Time: 14:56 [ET]
Event Date: 12/08/2009
Event Time: 13:28 [CST]
Last Update Date: 12/08/2009
Notification Time: 14:56 [ET]
Event Date: 12/08/2009
Event Time: 13:28 [CST]
Last Update Date: 12/08/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
MONTE PHILLIPS (R3DO)
MONTE PHILLIPS (R3DO)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | N | Y | 83 | Power Operation | 83 | Power Operation |
| 3 | N | Y | 99 | Power Operation | 99 | Power Operation |
TECHNICAL SUPPORT CENTER OUT OF SERVICE FOR PLANNED PREVENTATIVE MAINTENANCE
"At 1328 [CST] on Tuesday, December 8, 2009, the Dresden Nuclear Power Station (DNPS) Technical Support Center (TSC) emergency ventilation system was removed from service for planned preventative maintenance activities on the damper flow controller and air filtration charcoal system. During the maintenance, the non-emergency ventilation system will be functional. The TSC air filtration fan and dampers will be non-functional, rendering the TSC HVAC accident mode non-functional. This maintenance is scheduled to minimize out of service time. The planned TSC ventilation outage is scheduled to be completed within 48 hours. If an emergency is declared requiring TSC activation during this period, the TSC will be staffed and activated using existing EP [Emergency Planning] procedures and checklists. If radiological conditions require TSC facility evacuation during ventilation system restoration; the Station Emergency Director will evacuate and relocate the TSC staff in accordance with, EP-AA-112-200-F-01."
The licensee notified the NRC Resident Inspector.
"At 1328 [CST] on Tuesday, December 8, 2009, the Dresden Nuclear Power Station (DNPS) Technical Support Center (TSC) emergency ventilation system was removed from service for planned preventative maintenance activities on the damper flow controller and air filtration charcoal system. During the maintenance, the non-emergency ventilation system will be functional. The TSC air filtration fan and dampers will be non-functional, rendering the TSC HVAC accident mode non-functional. This maintenance is scheduled to minimize out of service time. The planned TSC ventilation outage is scheduled to be completed within 48 hours. If an emergency is declared requiring TSC activation during this period, the TSC will be staffed and activated using existing EP [Emergency Planning] procedures and checklists. If radiological conditions require TSC facility evacuation during ventilation system restoration; the Station Emergency Director will evacuate and relocate the TSC staff in accordance with, EP-AA-112-200-F-01."
The licensee notified the NRC Resident Inspector.