Event Notification Report for October 26, 2009

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
10/25/2009 - 10/26/2009

EVENT NUMBERS
454674546845502

!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 45467
Facility: FT CALHOUN
Region: 4     State: NE
Unit: [1] [] []
RX Type: [1] CE
NRC Notified By: ERICK MATZKE
HQ OPS Officer: KARL DIEDERICH
Notification Date: 10/26/2009
Notification Time: 12:47 [ET]
Event Date: 10/26/2009
Event Time: 10:50 [CDT]
Last Update Date: 11/18/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(ii)(B) - UNANALYZED CONDITION
Person (Organization):
DALE POWERS (R4DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
PRESSURIZER AND FEEDWATER STORAGE TANK LEVEL INDICATIONS DO NOT MEET APPENDIX R REQUIREMENTS

"During a review in preparation for converting from 10 CFR 50 Appendix R to NFPA 805, it was discovered that all of the cables for pressurizer and emergency feedwater storage tank level indications did not meet Appendix R cable requirements. A fire in Corridor 4, Corridor 26, or in Room 6 could result in a failure of level indication for these critical components. Corridors 4 and 26 were adequately addressed by existing fire watches. A fire watch was established for Room 6 upon discovery of this condition. Pressurizer level and emergency feedwater storage tank level indicators currently meet their requirements, with the established fire watches."

The licensee notified the NRC Resident Inspector.

* * * RETRACTION FROM ERICK MATZKE TO DONALD NORWOOD AT 1507 ON 11/18/2009 * * *

"On October 26, 2009, Fort Calhoun reported the [above event].

"During the course of the subsequent evaluation it was determined that the pressurizer level indications do meet the 10 CFR 50 Appendix R separation requirements. There is sufficient redundancy of emergency feedwater storage tank level indications to allow proper operator response to potential plant fires. Therefore, this event is not reportable."

The licensee notified the NRC Resident Inspector.

Notified R4DO (Proulx).


Power Reactor
Event Number: 45468
Facility: FT CALHOUN
Region: 4     State: NE
Unit: [1] [] []
RX Type: [1] CE
NRC Notified By: ERICK MATZKE
HQ OPS Officer: KARL DIEDERICH
Notification Date: 10/26/2009
Notification Time: 16:50 [ET]
Event Date: 10/26/2009
Event Time: 10:50 [CDT]
Last Update Date: 10/26/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
DALE POWERS (R4DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
STATION PAGING SYSTEM OUT OF SERVICE

"At about 1050 CDT on 10/26/2009, it was discovered that the station paging system was not operating. Repair efforts were initiated. The Control Room was notified of the pager outage. The automated callout system was available during the pager outage.

"Investigation determined that the paging system was nonfunctional as early as 0900 the same day.

"Repair efforts were successful and the pager system was returned to operation about 1230 CDT."

The licensee notified the NRC Resident Inspector.


General Information or Other
Event Number: 45502
Rep Org: FLORIDA BUREAU OF RADIATION CONTROL
Licensee: BOCA RATON COMMUNITY HOSPITAL
Region: 1
City: BOCA RATON   State: FL
County:
License #: 0550-1
Agreement: Y
Docket:
NRC Notified By: STEVE FURNACE
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 11/17/2009
Notification Time: 13:50 [ET]
Event Date: 10/26/2009
Event Time: 00:00 [EST]
Last Update Date: 11/17/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
RAYMOND MCKINLEY (R1DO)
ANGELA MCINTOSH (FSME)
Event Text
AGREEMENT STATE REPORT - MEDICAL EVENT

The following report was received via facsimile:

"Patient liver is being treated by thera sphere procedure. First dose was intended to be for left lobe but was delivered to right lobe on 10/26/09. The second treatment was going to be for the right lobe. The window for the right lobe dose was 90-115 grays, but what actually delivered was 18-51 % low. Error was discovered 10/30/09. The patient will be retreated to bring dose up to required level. The patient and doctor have been notified. In the future the radiologist will submit a written statement on the treatment to be preformed before it is accomplished. Licensee will submit a written report. No further action will be taken on this incident."

Source: 1.27 GBq Y-90

Florida Incident: FL09-077

A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.