Event Notification Report for October 24, 2009
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
10/23/2009 - 10/24/2009
Power Reactor
Event Number: 45466
Facility: PRAIRIE ISLAND
Region: 3 State: MN
Unit: [1] [2] []
RX Type: [1] W-2-LP,[2] W-2-LP
NRC Notified By: WAYNE EPPEN
HQ OPS Officer: BILL HUFFMAN
Region: 3 State: MN
Unit: [1] [2] []
RX Type: [1] W-2-LP,[2] W-2-LP
NRC Notified By: WAYNE EPPEN
HQ OPS Officer: BILL HUFFMAN
Notification Date: 10/24/2009
Notification Time: 17:07 [ET]
Event Date: 10/24/2009
Event Time: 13:20 [CDT]
Last Update Date: 10/24/2009
Notification Time: 17:07 [ET]
Event Date: 10/24/2009
Event Time: 13:20 [CDT]
Last Update Date: 10/24/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
LAURA KOZAK (R3DO)
LAURA KOZAK (R3DO)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | N | 0 | Cold Shutdown | 0 | Cold Shutdown |
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
OFFSITE NOTIFICATION OF MINOR OIL SPILL
"A light film of oil was discovered on the recycle canal of the plant water ways. The source was from residual oil on the deck of a small barge parked on the canal. Snow melt-off carried the oil into the canal. The barge is being used to dredge the canal. The quantity was estimated at less than 1/2 cup [of oil]. The oil is being cleaned up with oil absorbent booms and pads. The oil was contained to the plant water ways and was not discharged to the Mississippi River.
"Xcel Energy Services was notified. Xcel notified the National Response Center (Rpt #921543) and the Minnesota Division of Emergency Management (Rpt #107021). The licensee has covered the barge to prevent any further spill and will continue to monitor conditions."
The NRC Resident Inspector has been notified.
"A light film of oil was discovered on the recycle canal of the plant water ways. The source was from residual oil on the deck of a small barge parked on the canal. Snow melt-off carried the oil into the canal. The barge is being used to dredge the canal. The quantity was estimated at less than 1/2 cup [of oil]. The oil is being cleaned up with oil absorbent booms and pads. The oil was contained to the plant water ways and was not discharged to the Mississippi River.
"Xcel Energy Services was notified. Xcel notified the National Response Center (Rpt #921543) and the Minnesota Division of Emergency Management (Rpt #107021). The licensee has covered the barge to prevent any further spill and will continue to monitor conditions."
The NRC Resident Inspector has been notified.
General Information or Other
Event Number: 45465
Rep Org: WESTINGHOUSE ELECTRIC COMPANY
Licensee: WESTINGHOUSE ELECTRIC COMPANY
Region: 1
City: PITTSBURGH State: PA
County:
License #:
Agreement: Y
Docket:
NRC Notified By: J. A. GRESHAM
HQ OPS Officer: VINCE KLCO
Licensee: WESTINGHOUSE ELECTRIC COMPANY
Region: 1
City: PITTSBURGH State: PA
County:
License #:
Agreement: Y
Docket:
NRC Notified By: J. A. GRESHAM
HQ OPS Officer: VINCE KLCO
Notification Date: 10/24/2009
Notification Time: 12:11 [ET]
Event Date: 10/24/2009
Event Time: 00:00 [EDT]
Last Update Date: 01/14/2010
Notification Time: 12:11 [ET]
Event Date: 10/24/2009
Event Time: 00:00 [EDT]
Last Update Date: 01/14/2010
Emergency Class: NON EMERGENCY
10 CFR Section:
21.21 - UNSPECIFIED PARAGRAPH
10 CFR Section:
21.21 - UNSPECIFIED PARAGRAPH
Person (Organization):
LAWRENCE DOERFLEIN (R1DO)
JAY HENSON (R2DO)
LAURA KOZAK (R3DO)
NEIL OKEEFE (R4DO)
JOHN THORP(e-mail) (NRR)
LAWRENCE DOERFLEIN (R1DO)
JAY HENSON (R2DO)
LAURA KOZAK (R3DO)
NEIL OKEEFE (R4DO)
JOHN THORP(e-mail) (NRR)
POTENTIAL AGGRESSIVE WEARING OF ROD CLUSTER CONTROL ASSEMBLY GUIDE CARDS
"Aggressive wearing of the RCCA [Rod Cluster Control Assembly] guide card has been observed at an international plant. Such aggressive wear has not been observed in any US plants. If this issue were to remain uncorrected, it is possible for enough wear to occur during the life of the plant that the RCCAs could become unguided and may not properly insert into the core. It has not been concluded whether there is a safety hazard which would result from this deviation."
* * * UPDATE FROM GRESHAM TO CHUCK TEAL VIA FAX AT 1213 EST ON 1/14/2010 * * *
"Aggressive wearing of the Rod Cluster Control Assembly (RCCA) guide card has been observed at an international plant. Such aggressive wear has not been observed in any other plants. If this issue were to remain uncorrected, it was postulated that enough wear could occur during the life of the plant that the RCCAs could become unguided and may not properly insert into the core.
"With the exception of the one international plant in which abnormal excessive wear has been found, the conclusion from the analysis of the collection of wear data and the analysis of rodlet insertion with worn guide cards is that there is no concern for safe operation of any plant regarding guide tube wear for the 40-year design life. The engineering analysis supports this conclusion regardless of the type of RCCA guide tube or the RCCA rodlet material currently in use. For the international plant with the excessive wear, years of continued safe operation is available, and a justification for continued operation has been provided to the utility. Directives in Materials Reliability Program (MRP 227) will necessitate guide tube inspections as part of life extension licensing.
"Concerning AP 1000, a guide tube wear analysis has been performed. The analysis demonstrates operability for the 60-year design life for the shutdown control rods.
"Based on the above evaluation results, it has been determined that this issue does not represent a substantial safety hazard pursuant to the requirements delineated in I0CFR Part 21 ."
"Aggressive wearing of the RCCA [Rod Cluster Control Assembly] guide card has been observed at an international plant. Such aggressive wear has not been observed in any US plants. If this issue were to remain uncorrected, it is possible for enough wear to occur during the life of the plant that the RCCAs could become unguided and may not properly insert into the core. It has not been concluded whether there is a safety hazard which would result from this deviation."
* * * UPDATE FROM GRESHAM TO CHUCK TEAL VIA FAX AT 1213 EST ON 1/14/2010 * * *
"Aggressive wearing of the Rod Cluster Control Assembly (RCCA) guide card has been observed at an international plant. Such aggressive wear has not been observed in any other plants. If this issue were to remain uncorrected, it was postulated that enough wear could occur during the life of the plant that the RCCAs could become unguided and may not properly insert into the core.
"With the exception of the one international plant in which abnormal excessive wear has been found, the conclusion from the analysis of the collection of wear data and the analysis of rodlet insertion with worn guide cards is that there is no concern for safe operation of any plant regarding guide tube wear for the 40-year design life. The engineering analysis supports this conclusion regardless of the type of RCCA guide tube or the RCCA rodlet material currently in use. For the international plant with the excessive wear, years of continued safe operation is available, and a justification for continued operation has been provided to the utility. Directives in Materials Reliability Program (MRP 227) will necessitate guide tube inspections as part of life extension licensing.
"Concerning AP 1000, a guide tube wear analysis has been performed. The analysis demonstrates operability for the 60-year design life for the shutdown control rods.
"Based on the above evaluation results, it has been determined that this issue does not represent a substantial safety hazard pursuant to the requirements delineated in I0CFR Part 21 ."