Event Notification Report for October 10, 2009

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
10/09/2009 - 10/10/2009

EVENT NUMBERS
45424

!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 45424
Facility: MONTICELLO
Region: 3     State: MN
Unit: [1] [] []
RX Type: [1] GE-3
NRC Notified By: TIM CORRIGAN
HQ OPS Officer: CHARLES TEAL
Notification Date: 10/10/2009
Notification Time: 14:34 [ET]
Event Date: 10/10/2009
Event Time: 13:21 [CDT]
Last Update Date: 12/04/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
JULIO LARA (R3DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
CONTROL ROOM FILTRATION OUT OF SERVICE FOR MAINTAINANCE

"Post maintenance operability testing of the 'A' CREF (Control Room Emergency Filtration) subsystem will result in a planned potential loss of safety function for the CREF for a brief period of time when the 'B' CREF subsystem is simultaneously made inoperable during the testing. Clear guidance for timely restoration of the 'B' CREF subsystem, and therefore, CREF safety function is included in the test procedure. An operator will be dedicated to the testing to ensure that the CREF will perform its safety function if required."

The licensee will notify the NRC Resident Inspector.

* * * RETRACTION AT 1525 EST ON 12/04/09 FROM COOK TO HUFFMAN * * *

"Monticello is retracting the event reported based on further evaluation. An investigation of the event found the removal of the [CREF] system from service was part of a planned evolution for maintenance or surveillance testing and done in accordance with an approved procedure and the plant's TS [Technical Specifications]. In addition, the event would not have prevented the completion of the fulfillment of a safety function since an operator was stationed and briefed that in the event of the start of any transient, the CREF system would be immediately restored to operability and thereby ensure the train would have been available to perform its safety function In its required timeframe. The licensee has notified the NRC Resident Inspector."

R3DO (Riemer) notified.