Skip to main content

Event Notification Report for September 25, 2009

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
09/24/2009 - 09/25/2009

EVENT NUMBERS
4538545382

General Information or Other
Event Number: 45385
Rep Org: COLORADO DEPT OF HEALTH
Licensee: TEAM INDUSTRIAL SERVICES
Region: 4
City: DENVER   State: CO
County:
License #: 388-01
Agreement: Y
Docket:
NRC Notified By: JAMES JARVIS
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 09/28/2009
Notification Time: 12:14 [ET]
Event Date: 09/25/2009
Event Time: 13:00 [MDT]
Last Update Date: 09/28/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
MICHAEL SHANNON (R4DO)
ANGELA MCINTOSH (FSME)
Event Text
AGREEMENT STATE REPORT - SOURCE DISCONNECTED FROM RADIOGRAPHY CAMERA

The following agreement state report was received via e-mail:

"On September 25, 2009 (at approximately 14:45 MDT), the Colorado Department of Public Health and Environment was notified by the RSO for Team Industrial Services that a source disconnect had occurred within the prior 1-2 hours at a temporary jobsite located in Rifle, Colorado. The source remained disconnected at the time the RSO made the notification to the Department as no personnel working in the area were trained for source recovery operations. Once the radiographer in charge at the jobsite realized that a disconnect had occurred and the source could not be returned to the radiography device, the source was cranked/pushed out to the collimator to provide additional shielding.

"The RSO reported that the radiographer and radiographer assistant involved in the source disconnect had received approximately 1 mrem up to and including the time of the source disconnect. According to the RSO, the temporary jobsite was located adjacent to an oil or gas drilling rig site, but radiography operations were located at a sufficient distance so as not to impact other non-radiography personnel (members of the public) working in the vicinity. Additional (licensee) radiography crews working in the Rifle, CO area were dispatched to the jobsite where the disconnect had occurred to provide additional support and access control.

"On September 26, 2009 (at approximately 11:08 am MDT), the licensee notified the Department that the source recovery had been successfully completed by the RSO at about 1:30 am MDT that morning. The personnel involved in the source recovery - including the RSO - had received approximately 8 mrem each based upon pocket dosimeter readings.

"The event involved a radiography device containing 35.6 curies of Ir-192. The source had been in use for several months and the source was nearing the end of its useful life. The radiography device involved in the disconnect was a Sentinel Delta 880 (Serial #D4309) containing approximately 35.6 Ci of Ir-192. The Ir-192 source was a Model 424-9, Serial #53922B.

"The Department [Colorado Department of Health] recommended to the licensee that the device and source be returned to the manufacturer for further evaluation. The licensee is expected to submit a written report to the Department within 30 days of the incident.

"Colorado Incident #I09-19"


General Information or Other
Event Number: 45382
Rep Org: TEXAS DEPARTMENT OF HEALTH
Licensee: BETABATT
Region: 4
City: ALVIN   State: TX
County:
License #: L-05961
Agreement: Y
Docket:
NRC Notified By: ART TUCKER
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 09/25/2009
Notification Time: 14:50 [ET]
Event Date: 09/25/2009
Event Time: 12:45 [CDT]
Last Update Date: 10/16/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
MICHAEL SHANNON (R4DO)
ANGELA MCINTOSH (FSME)
Event Text
AGREEMENT STATE REPORT - LEAKING SEALED SOURCE OF TRITIUM

"On September 1, 2009, the Agency [Texas DEH] received a call from the Florida Bureau of Radiation Control notifying them that during a routine inspection of a facility in Florida, they found tritium contamination on and outside of a container that contained a prototype tritium battery sent to them by a company in Alvin, Texas. The Radiation Safety Officer (RSO) at the Texas facility was contacted by this Agency [Florida]. The RSO stated that the facility had shipped two of the six batteries they had made from their facility to Florida. He stated that they had not had contamination issues in the past with these batteries and he believed the contamination event was caused by the testing facility when they opened the outer battery housing to determine the cause of a failure. He stated that they had not experienced any significant contamination issues at their facility.

"On September 18, 2009, in response to additional information provided by the State of Florida, an Agency [Texas DEH] inspector conducted an onsite investigation at the facility in Alvin. The inspector performed a removable contamination survey in the area where the batteries are handled and stored. During his investigation of the event, the inspector learned that the seven batteries were manufactured in a city outside of the State of Texas. One was shipped to the facility in Florida directly, and six were shipped to the facility in Alvin, Texas.

"On September 24, 2009, the Agency [Texas DEH] received notification that the results of the tritium survey done at the facility indicated all swipes exceeded the limit for unrestricted use. The Agency [Texas DEH] contacted the licensee and informed the licensee of their results. Documents regarding previous radiological surveys for the battery storage area, leak test of the 3D diodes, receipt survey on the six 3D diodes that were sent from the manufacturer, and any Bioassays that have been performed on their staff were requested from the licensee.

"On September 25, 2009, at 12:45 PM (local) the Agency [Texas DEH] was notified by the licensee that the area had been isolated and that decontamination work would go on for an undetermined period of time. The licensee has begun providing the requested information. Updates will be provided as additional pertinent information is obtained."

Texas Incident #I-8668.

See also Event Notification #45358 for the notification made by the State of Florida on the same event.

* * * UPDATE AT 1745 EDT ON 10/16/09 FROM ART TUCKER TO S. SANDIN * * *

The following update was received from the State of Texas via email:

"On October 13, 2009, the Agency received copies of surveys performed by BetaBatt at their Texas facility. These surveys indicated contamination levels of tritium to be between 8,000 dpm and 300,000 dpm after the first decontamination effort, and between 51,325 dpm and 16,500 dpm after the second decontamination effort. The licensee is considering additional decontamination techniques to reduce the activity. The report also indicated that two individuals had received bioassay analysis. The results indicated that the two individuals had received small body burdens. The licensee has contacted Rice University and REAC/TS for assistance."

Notified R4DO(Cain) and FSME EO(Delligatti).