Event Notification Report for September 02, 2009
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
09/01/2009 - 09/02/2009
General Information or Other
Event Number: 45322
Rep Org: TEXAS DEPARTMENT OF HEALTH
Licensee: LIBERTY PRESSURE PUMPING
Region: 4
City: FORT WORTH State: TX
County:
License #: G02259
Agreement: Y
Docket:
NRC Notified By: RAY JISHA
HQ OPS Officer: DONG HWA PARK
Licensee: LIBERTY PRESSURE PUMPING
Region: 4
City: FORT WORTH State: TX
County:
License #: G02259
Agreement: Y
Docket:
NRC Notified By: RAY JISHA
HQ OPS Officer: DONG HWA PARK
Notification Date: 09/02/2009
Notification Time: 10:43 [ET]
Event Date: 09/02/2009
Event Time: 08:40 [CDT]
Last Update Date: 09/02/2009
Notification Time: 10:43 [ET]
Event Date: 09/02/2009
Event Time: 08:40 [CDT]
Last Update Date: 09/02/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
THOMAS FARNHOLTZ (R4DO)
MARK THAGGARD (FSME)
THOMAS FARNHOLTZ (R4DO)
MARK THAGGARD (FSME)
AGREEMENT STATE REPORT - MOBILE SLURRY UNIT CAUGHT ON FIRE
The following report was received via email from the State of Texas:
"A mobile slurry unit (authorized under TX license G02259) in which a 200mCi, Cs-137, Thermo Fischer Scientific Model 5190 density gauge was mounted, caught fire. This occurred at an oil field temporary job site south of Fort Worth, TX. It was relayed that the fire had melted the lead at the top of the shield exposing the source as evidenced by elevated readings with a survey meter. It is believed that the source remains in the holder and has not been breached. Further, the gauge housing is still intact and [the] plan (already instituted) is to have the manufacturer remove the gauge for disposal at their facility. The device and source serial number are B7274 and CN-3171 respectively.
"There was no exposure to anybody in excess of agency limits due to the manner in which the units were parked."
Texas report # I-8662
The following report was received via email from the State of Texas:
"A mobile slurry unit (authorized under TX license G02259) in which a 200mCi, Cs-137, Thermo Fischer Scientific Model 5190 density gauge was mounted, caught fire. This occurred at an oil field temporary job site south of Fort Worth, TX. It was relayed that the fire had melted the lead at the top of the shield exposing the source as evidenced by elevated readings with a survey meter. It is believed that the source remains in the holder and has not been breached. Further, the gauge housing is still intact and [the] plan (already instituted) is to have the manufacturer remove the gauge for disposal at their facility. The device and source serial number are B7274 and CN-3171 respectively.
"There was no exposure to anybody in excess of agency limits due to the manner in which the units were parked."
Texas report # I-8662
Power Reactor
Event Number: 45323
Facility: NINE MILE POINT
Region: 1 State: NY
Unit: [] [2] []
RX Type: [1] GE-2,[2] GE-5
NRC Notified By: THOMAS TANGUAY
HQ OPS Officer: DONALD NORWOOD
Region: 1 State: NY
Unit: [] [2] []
RX Type: [1] GE-2,[2] GE-5
NRC Notified By: THOMAS TANGUAY
HQ OPS Officer: DONALD NORWOOD
Notification Date: 09/02/2009
Notification Time: 19:20 [ET]
Event Date: 09/02/2009
Event Time: 08:30 [EDT]
Last Update Date: 09/10/2009
Notification Time: 19:20 [ET]
Event Date: 09/02/2009
Event Time: 08:30 [EDT]
Last Update Date: 09/10/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
JAMES DWYER (R1DO)
JAMES DWYER (R1DO)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
LOSS OF SPDS COMPUTER
"This 8-hour non-emergency report is being made based upon requirements of 10CFR50.72(b)(3)(xiii) which states, 'The licensee shall notify the NRC as soon as practical and in all cases within eight hours of the occurrence of any event that results in a major loss of emergency assessment capability, offsite response capability, or offsite communications capability (e.g., significant portion of control room indication, Emergency Notification System, or offsite notification system).' An example of a major loss of emergency assessment capability is when the Safety Parameter Display System (SPDS) computer is unavailable for greater than eight hours.
"At 0830 EDT on Wednesday, September 02, 2009 the SPDS Computer was found by the computer department to have one of three interface modules failed. The interface module transports data from the radwaste computer to SPDS. The failure resulted in a loss of 187 SPDS points.
"All other SPDS points along with Plant Process Computer functions are available. Information Technology Department personnel are investigating the cause of the interface module failure, which is currently unknown.
"No other control room emergency assessment capabilities have been adversely affected. All Control Room panel indicators and annunciators are responding properly."
The licensee notified the NRC Resident Inspector.
* * * UPDATE ON 09/10/09 AT 1107 EDT FROM JASON SAWYER TO DONG PARK * * *
"The Safety Parameter Display System [SPDS] was returned to service at 1030 EDT on 9/10/2009. Degraded SPDS components have been repaired and SPDS has been verified to be functional and capable of meeting all required design functions.
"The licensee has notified the NRC Resident Inspector."
Notified R1DO (Powell).
"This 8-hour non-emergency report is being made based upon requirements of 10CFR50.72(b)(3)(xiii) which states, 'The licensee shall notify the NRC as soon as practical and in all cases within eight hours of the occurrence of any event that results in a major loss of emergency assessment capability, offsite response capability, or offsite communications capability (e.g., significant portion of control room indication, Emergency Notification System, or offsite notification system).' An example of a major loss of emergency assessment capability is when the Safety Parameter Display System (SPDS) computer is unavailable for greater than eight hours.
"At 0830 EDT on Wednesday, September 02, 2009 the SPDS Computer was found by the computer department to have one of three interface modules failed. The interface module transports data from the radwaste computer to SPDS. The failure resulted in a loss of 187 SPDS points.
"All other SPDS points along with Plant Process Computer functions are available. Information Technology Department personnel are investigating the cause of the interface module failure, which is currently unknown.
"No other control room emergency assessment capabilities have been adversely affected. All Control Room panel indicators and annunciators are responding properly."
The licensee notified the NRC Resident Inspector.
* * * UPDATE ON 09/10/09 AT 1107 EDT FROM JASON SAWYER TO DONG PARK * * *
"The Safety Parameter Display System [SPDS] was returned to service at 1030 EDT on 9/10/2009. Degraded SPDS components have been repaired and SPDS has been verified to be functional and capable of meeting all required design functions.
"The licensee has notified the NRC Resident Inspector."
Notified R1DO (Powell).
General Information or Other
Event Number: 45540
Rep Org: PA BUREAU OF RADIATION PROTECTION
Licensee: FOX CHASE CANCER CENTER
Region: 1
City: PHILADELPHIA State: PA
County:
License #: PA-0293
Agreement: Y
Docket:
NRC Notified By: DAVID ALLARD
HQ OPS Officer: VINCE KLCO
Licensee: FOX CHASE CANCER CENTER
Region: 1
City: PHILADELPHIA State: PA
County:
License #: PA-0293
Agreement: Y
Docket:
NRC Notified By: DAVID ALLARD
HQ OPS Officer: VINCE KLCO
Notification Date: 12/03/2009
Notification Time: 17:19 [ET]
Event Date: 09/02/2009
Event Time: 00:00 [EST]
Last Update Date: 12/03/2009
Notification Time: 17:19 [ET]
Event Date: 09/02/2009
Event Time: 00:00 [EST]
Last Update Date: 12/03/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
DANIEL HOLODY (R1DO)
BILL VONTILL (FSME)
DANIEL HOLODY (R1DO)
BILL VONTILL (FSME)
AGREEMENT STATE REPORT - MEDICAL DOSE DIFFERENT THAN PRESCRIBED
The following information was received via facsimile:
"This incident was reported to the DEP [Pennsylvania Department of Environmental Protection Bureau of Radiation Protection] Eastern Regional Office by the licensee via a phone call on September 3, 2009, but wasn't considered a ME [Medical Event] by DEP at the time. On September 2, 2009 a patient was prescribed a dose of 150 millicuries (mCi) of radioactive iodine-131 (I-131) for a therapeutic treatment of thyroid cancer. The nuclear medicine technologist took the 150 mCi dose to the patient's room in a lead container and made the appropriate tube connections. The connections were checked with water prior to administration of the I-131 and no leaks were present. The dose was administered. During the flushing process, the technologist noted some leakage of liquid on the absorbent material that was placed under the tubing. The syringe, tubing, and absorbent material were immediately removed and assayed in the dose calibrator. It was determined that 57.6% of the prescribed dose had been administered to the patient. A second written directive for an additional dose prescribed by the authorized user was delivered to provide assurance that the patient received the appropriate complete amount of radioactive iodine for treatment of the thyroid cancer.
"During an inspection of Fox Chase on December 1, 2009, this incident was reviewed by the DEP. At this point the licensee informed DEP that they considered this a ME, had notified the patient, thus, the reason for this fax ME notification to the NRC HOO [Headquarter Operation Officer] at this point in time. Additional details will be provided in the NMED report."
Pennsylvania Event Report: PA090034.
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
The following information was received via facsimile:
"This incident was reported to the DEP [Pennsylvania Department of Environmental Protection Bureau of Radiation Protection] Eastern Regional Office by the licensee via a phone call on September 3, 2009, but wasn't considered a ME [Medical Event] by DEP at the time. On September 2, 2009 a patient was prescribed a dose of 150 millicuries (mCi) of radioactive iodine-131 (I-131) for a therapeutic treatment of thyroid cancer. The nuclear medicine technologist took the 150 mCi dose to the patient's room in a lead container and made the appropriate tube connections. The connections were checked with water prior to administration of the I-131 and no leaks were present. The dose was administered. During the flushing process, the technologist noted some leakage of liquid on the absorbent material that was placed under the tubing. The syringe, tubing, and absorbent material were immediately removed and assayed in the dose calibrator. It was determined that 57.6% of the prescribed dose had been administered to the patient. A second written directive for an additional dose prescribed by the authorized user was delivered to provide assurance that the patient received the appropriate complete amount of radioactive iodine for treatment of the thyroid cancer.
"During an inspection of Fox Chase on December 1, 2009, this incident was reviewed by the DEP. At this point the licensee informed DEP that they considered this a ME, had notified the patient, thus, the reason for this fax ME notification to the NRC HOO [Headquarter Operation Officer] at this point in time. Additional details will be provided in the NMED report."
Pennsylvania Event Report: PA090034.
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.