Event Notification Report for August 20, 2009
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
08/19/2009 - 08/20/2009
Power Reactor
Event Number: 45279
Facility: MONTICELLO
Region: 3 State: MN
Unit: [1] [] []
RX Type: [1] GE-3
NRC Notified By: LEROY ANDERSON
HQ OPS Officer: PETE SNYDER
Region: 3 State: MN
Unit: [1] [] []
RX Type: [1] GE-3
NRC Notified By: LEROY ANDERSON
HQ OPS Officer: PETE SNYDER
Notification Date: 08/20/2009
Notification Time: 15:19 [ET]
Event Date: 08/20/2009
Event Time: 08:38 [CDT]
Last Update Date: 08/20/2009
Notification Time: 15:19 [ET]
Event Date: 08/20/2009
Event Time: 08:38 [CDT]
Last Update Date: 08/20/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(ii)(B) - UNANALYZED CONDITION 50.72(b)(3)(v)(B) - POT RHR INOP 50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
10 CFR Section:
50.72(b)(3)(ii)(B) - UNANALYZED CONDITION 50.72(b)(3)(v)(B) - POT RHR INOP 50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
JACK GIESSNER (R3DO)
JACK GIESSNER (R3DO)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
BOTH DIVISIONS OF VITAL SWITCHGEAR INOPERABLE BECAUSE FLOOD DOOR FOUND CLOSED
"At 08:38 on 08/20/09, a plant operator identified that DOOR-18, which is a normally open fire door, had closed due to a failed fusible link. With this door closed, the pathway for a potential flood due to a high energy line break (HELB) is blocked therefore closing off a drain path for the water. This represented an unanalyzed condition where both divisions of essential switchgear could be impacted. As a result, both divisions of essential switchgear were declared inoperable and Technical Specification LCO 3.0.3 was entered.
"With both switchgear divisions being inoperable, this condition is also an event that could have prevented fulfillment of a Safely Function and reportable under 50.72(b)(3)(v). At 0942 on 08/20/09, the closed fire door was restored to the open state. Both divisions of switchgear were declared Operable and LCO 3.0.3 was exited. No system actuations occurred as a part of this event."
A continuous fire watch was posted as a compensatory measure while the fire door is being repaired.
The licensee notified the NRC Resident Inspector.
"At 08:38 on 08/20/09, a plant operator identified that DOOR-18, which is a normally open fire door, had closed due to a failed fusible link. With this door closed, the pathway for a potential flood due to a high energy line break (HELB) is blocked therefore closing off a drain path for the water. This represented an unanalyzed condition where both divisions of essential switchgear could be impacted. As a result, both divisions of essential switchgear were declared inoperable and Technical Specification LCO 3.0.3 was entered.
"With both switchgear divisions being inoperable, this condition is also an event that could have prevented fulfillment of a Safely Function and reportable under 50.72(b)(3)(v). At 0942 on 08/20/09, the closed fire door was restored to the open state. Both divisions of switchgear were declared Operable and LCO 3.0.3 was exited. No system actuations occurred as a part of this event."
A continuous fire watch was posted as a compensatory measure while the fire door is being repaired.
The licensee notified the NRC Resident Inspector.
Power Reactor
Event Number: 45280
Facility: SUSQUEHANNA
Region: 1 State: PA
Unit: [] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: DAVE BORGER
HQ OPS Officer: MARK ABRAMOVITZ
Region: 1 State: PA
Unit: [] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: DAVE BORGER
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 08/20/2009
Notification Time: 20:14 [ET]
Event Date: 08/20/2009
Event Time: 16:43 [EDT]
Last Update Date: 08/25/2009
Notification Time: 20:14 [ET]
Event Date: 08/20/2009
Event Time: 16:43 [EDT]
Last Update Date: 08/25/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
RICHARD CONTE (R1DO)
RICHARD CONTE (R1DO)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | N | Y | 94 | Power Operation | 94 | Power Operation |
LOSS OF PLANT INTEGRATED COMPUTER SYSTEM RESULTING IN LOSS OF ERDS AND SPDS
"At 0950 the Plant Integrated Computer System started to fail as indicated by a loss of computer link to Generation. Investigation by computer maintenance personnel was initiated. The failure mode of the computer precluded accessing screens to allow use of Safety Parameter Display System (SPDS) and Emergency Response Data System (ERDS). Computer core thermal power indication remained available to the control room operators. Redundant, normal control room indications are still available to the operators. At 1217 hours on 08/20/09, a planned loss of computer core thermal power indication occurred due to ongoing computer maintenance activities.
"At 1458 hours on 08/20/09, the Plant Integrated Computer System was fully restored to service, including the Safety Parameter Display System (SPDS) and Emergency Response Data System (ERDS) functions. At 1643 hours on 08/20/09, the Plant Integrated Computer System started to fail again as indicated by loss of computer link to Generation. This problem with the computer again precluded accessing Safety Parameter Display System (SPDS) and Emergency Response Data System (ERDS). Core thermal power indication remained available via the plant computer system. However, anticipated troubleshooting actions will require a reduction in power by approximately 0.25-0.33% by reducing core flow.
"Due to the cumulative impacts of the loss of the plant computer system, this notification is being communicated ahead of the 8 hour unavailability of the Unit 2 SPDS and ERDS computer system. This is considered a Loss of Emergency Assessment Capability and therefore reportable under 10CFR50.72(b)(3)(xiii)."
The licensee notified the NRC Resident Inspector.
* * * UPDATE FROM RICHARD KLINEFELTER TO CHARLES TEAL AT 1222 EDT ON 8/25/2009 * * *
As of 1200 hours, Unit 2 ERDS and SPDS (Safety Parameter Display System) were restored to normal operation.
The licensee has notified the NRC Resident Inspector. Notified R1DO (White).
"At 0950 the Plant Integrated Computer System started to fail as indicated by a loss of computer link to Generation. Investigation by computer maintenance personnel was initiated. The failure mode of the computer precluded accessing screens to allow use of Safety Parameter Display System (SPDS) and Emergency Response Data System (ERDS). Computer core thermal power indication remained available to the control room operators. Redundant, normal control room indications are still available to the operators. At 1217 hours on 08/20/09, a planned loss of computer core thermal power indication occurred due to ongoing computer maintenance activities.
"At 1458 hours on 08/20/09, the Plant Integrated Computer System was fully restored to service, including the Safety Parameter Display System (SPDS) and Emergency Response Data System (ERDS) functions. At 1643 hours on 08/20/09, the Plant Integrated Computer System started to fail again as indicated by loss of computer link to Generation. This problem with the computer again precluded accessing Safety Parameter Display System (SPDS) and Emergency Response Data System (ERDS). Core thermal power indication remained available via the plant computer system. However, anticipated troubleshooting actions will require a reduction in power by approximately 0.25-0.33% by reducing core flow.
"Due to the cumulative impacts of the loss of the plant computer system, this notification is being communicated ahead of the 8 hour unavailability of the Unit 2 SPDS and ERDS computer system. This is considered a Loss of Emergency Assessment Capability and therefore reportable under 10CFR50.72(b)(3)(xiii)."
The licensee notified the NRC Resident Inspector.
* * * UPDATE FROM RICHARD KLINEFELTER TO CHARLES TEAL AT 1222 EDT ON 8/25/2009 * * *
As of 1200 hours, Unit 2 ERDS and SPDS (Safety Parameter Display System) were restored to normal operation.
The licensee has notified the NRC Resident Inspector. Notified R1DO (White).