Skip to main content

Event Notification Report for July 10, 2009

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
07/09/2009 - 07/10/2009

EVENT NUMBERS
45193451954532445254

Power Reactor
Event Number: 45193
Facility: PEACH BOTTOM
Region: 1     State: PA
Unit: [2] [3] []
RX Type: [2] GE-4,[3] GE-4
NRC Notified By: LARRY KEEHNER
HQ OPS Officer: CHARLES TEAL
Notification Date: 07/10/2009
Notification Time: 13:40 [ET]
Event Date: 07/10/2009
Event Time: 12:31 [EDT]
Last Update Date: 07/10/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
GLENN DENTEL (R1DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 100 Power Operation
3 N Y 100 Power Operation 100 Power Operation
Event Text
ELEVATED TRITIUM LEVELS FOUND IN ON-SITE WELL

"Exelon has issued a news release due to elevated levels of tritium found in an on-site exploratory well at the Peach Bottom Atomic Power Station. The elevated levels of tritium were found in an area adjacent to the Peach Bottom Unit 3 Turbine Building."

Tritium levels were measured as 123,000 picoCuries per liter.

The licensee notified the NRC Resident Inspector, Pennsylvania Emergency Management Agency, Maryland Emergency Management Agency, and the counties of York, Cecil, Lancaster, and Chester.


Fuel Cycle Facility
Event Number: 45195
Facility: HONEYWELL INTERNATIONAL, INC.
Region: 2     State: IL
Unit: [] [] []
RX Type: URANIUM HEXAFLUORIDE PRODUCTION
NRC Notified By: MICHAEL GREENO
HQ OPS Officer: DONALD NORWOOD
Notification Date: 07/12/2009
Notification Time: 00:08 [ET]
Event Date: 07/10/2009
Event Time: 20:00 [CDT]
Last Update Date: 07/14/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
40.60(b)(1) - UNPLANNED CONTAMINATION
Person (Organization):
REBECCA NEASE (R2DO)
MICHAEL TSCHILTZ (NMSS)
Event Text
UNPLANNED CONTAMINATION EVENT REQUIRING ADDITIONAL RADIOLOGICAL CONTROLS (RESPIRATORS) FOR MORE THAN 24 HOURS

"An unplanned contamination event occurred on 10 July 2009. This is a reportable event in accordance with 10CFR40.60 sub paragraph (1) based on an unplanned event that resulted in additional radiological controls being required for more than 24 hours. The 24 hour period ended at 2000 CDT on 11 July 2009 (the reported event). The additional control imposed was the wearing of air purifying respirators on the fourth floor of the Feed Materials Building. The location of the event was the Feed Materials Building fourth floor. The Feed Materials Building converts milled uranium oxide material to uranium hexafluoride by using a dry process. Air samples from the fourth floor were analyzed and the airborne radioactivity averaged approximately 6.11E-11 microcuries/ml. The airborne contaminant was natural uranium ore concentrate and the physical form is a light microscopic dust. The processes in the area of elevated levels of airborne radioactivity have been secured and potential leakage paths are being investigated.

"The licensee will notify NRC Region II."

HOO Note: See similar Event Numbers 44857, 44871, 45058, and 45163.

* * * UPDATE FROM MICHAEL GREENO TO HOWIE CROUCH @ 1628 EDT ON 7/14/09 * * *

The isotope responsible for the increased controls was natural uranium in the chemical form of uranium tetraflouride (UF4); green salt. The amount of unplanned contamination that was released in the form of green salt was estimated to exceed 5 times the ALI [Annual Limit on Intake] (3 grams). The airborne activity averaged approximately 6.11E-11 microCuries/ml. (5.0E-11 microCuries/ml is 30% of 1 DAC [Derived Air Concentration]).

The licensee states that bioassay sampling of any potentially exposed individuals will be performed within the routine sampling frequency, but prior to 7/30/09.

The licensee has notified NRC Region II. Notified R2DO (O'Donohue) and NMSS EO (Kotzalas).


Power Reactor
Event Number: 45324
Facility: THREE MILE ISLAND
Region: 1     State: PA
Unit: [1] [] []
RX Type: [1] B&W-L-LP,[2] B&W-L-LP
NRC Notified By: ADAM MILLER
HQ OPS Officer: DONG HWA PARK
Notification Date: 09/03/2009
Notification Time: 09:04 [ET]
Event Date: 07/10/2009
Event Time: 02:38 [EDT]
Last Update Date: 09/03/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
50.73(a)(1) - INVALID SPECIF SYSTEM ACTUATION
Person (Organization):
JAMES DWYER (R1DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
ELECTRICAL SHORT CIRCUIT RESULTED IN PARTIAL HIGH PRESSURE INJECTION

"This event is being reported via a telephone notification to the NRC Operations Center within 60 days after discovery of the event instead of submitting a written LER. In this case, the telephone report is not considered an LER. This report is being made under 10 CFR 50.73(a)(2)(iv)(A).

"During a maintenance activity to replace an Engineered Safeguards Actuation System (ESAS) relay, one of the two High Pressure Injection (HPI) valves (MU-V-16C) in the 'B' train partially opened. The HPI system consists of the 'A' and 'B' trains, with each train containing two HPI valves. The cause of the partial opening of the HPI valve was inadvertent contact with adjacent energized circuits during the replacement of the ESAS relay. This resulted in a momentary short circuit, which bypassed the normal actuation logic, causing the HPI valve to open approximately 0.17 inches before blowing the control power fuse that stopped the valve movement. The event resulted in the inadvertent transfer of approximately 1000 gallons of water from the Make-up Tank into the Reactor Coolant System (RCS), before the valve could be restored to the closed position. No other valves or components actuated as a result of the inadvertent short circuit. RCS volume and pressure were stabilized and returned to normal.

"The 'B' HPI train had been declared inoperable and the unit entered a 72 hour LCO at 1:03 AM on 7/10/2009 due to configuration requirements needed for the planned ESAS relay replacement. The inadvertent partial 'B' train HPI did not impact the 'A' HPI train, and the unit remained at full power during this event. Following troubleshooting and replacement of the control power fuse, MU-V-16C was tested and restored to OPERABLE at 4:59 AM on 7/11/2009.

"The licensee notified the NRC Resident Inspector."


Other Nuclear Material
Event Number: 45254
Rep Org: STATE OF CALIFORNIA
Licensee: UNIVERSITY OF CALIFORNIA, SANTA CRUZ
Region: 4
City: SANTA CRUZ   State: CA
County:
License #: 1337-44
Agreement: Y
Docket:
NRC Notified By: KENT PRENDERGAST
HQ OPS Officer: CHARLES TEAL
Notification Date: 08/10/2009
Notification Time: 18:37 [ET]
Event Date: 07/10/2009
Event Time: 00:00 [PDT]
Last Update Date: 08/10/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
JACK WHITTEN (R4DO)
KEITH McCONNELL (FSME)
Event Text
AGREEMENT STATE - LEAKING RADIOACTIVE SOURCE

The following was received from the state via email:

"The source housing from a 6.58 mCi Ni-63 electron capture device (ECD), (Varian Model 02-001972-00, S/N A2296) was inadvertently opened when the detector was removed from a gas chromatograph for storage. The situation was discovered by radiation safety staff, and followed up immediately. Removable contamination was detected on the open interior of the source assembly and on top of the gas chromatograph, but was less than the removable value of 0.005 microcuries. The detector foil was not damaged or accessed. All components of the source assembly were retrieved and will be disposed of as radioactive materials waste or returned to the vendor. "

CA Report #: 080509