Event Notification Report for June 24, 2009
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
06/23/2009 - 06/24/2009
EVENT NUMBERS
4516345161451564515746981
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Fuel Cycle Facility
Event Number: 45163
Facility: HONEYWELL INTERNATIONAL, INC.
Region: 2 State: IL
Unit: [] [] []
RX Type: URANIUM HEXAFLUORIDE PRODUCTION
NRC Notified By: MICHAEL GREENO
HQ OPS Officer: PETE SNYDER
Region: 2 State: IL
Unit: [] [] []
RX Type: URANIUM HEXAFLUORIDE PRODUCTION
NRC Notified By: MICHAEL GREENO
HQ OPS Officer: PETE SNYDER
Notification Date: 06/25/2009
Notification Time: 13:06 [ET]
Event Date: 06/24/2009
Event Time: 10:45 [CDT]
Last Update Date: 07/01/2009
Notification Time: 13:06 [ET]
Event Date: 06/24/2009
Event Time: 10:45 [CDT]
Last Update Date: 07/01/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
40.60(b)(1) - UNPLANNED CONTAMINATION
10 CFR Section:
40.60(b)(1) - UNPLANNED CONTAMINATION
Person (Organization):
GERALD MCCOY (R2DO)
BRIAN SMITH (NMSS)
GERALD MCCOY (R2DO)
BRIAN SMITH (NMSS)
ACCESS RESTRICTION DUE TO UNPLANNED CONTAMINATION
"An unplanned airborne contamination event occurred beginning June 24, 2009 at 1045 at the Honeywell Metropolis, IL facilities' pond mud calciner area. Access was restricted to the area by requiring respiratory protection to be worn.
"Average airborne concentrations during the following 24 hour period were 7.19 E -11 microcuries per cubic centimeter which exceeds the administrative limit of 5 E -12 microcuries per cubic centimeter. Natural uranium dust was the isotope involved.
"There was no known effect to employees. This event is being entered into the facilities corrective action program."
* * * UPDATE AT 1020 EDT ON 07/01/09 FROM BOB STOKES TO S. SANDIN * * *
The licensee is retracting this report based on the following:
"[The licensee is] withdraw[ing] the event reported June 25th, 2009 Event Number 45163. Following a review of the circumstances associated with the report [the licensee] determined that the event did not meet the criteria as described in 10CFR40.60(b). The event review determined that the contamination event was expected. And the area DID have a respiratory protection requirement in place at the time of the elevated air activity."
The licensee informed NRC Region 2 (John Pelchat). Notified R2DO (Musser) and NMSS (Easton).
"An unplanned airborne contamination event occurred beginning June 24, 2009 at 1045 at the Honeywell Metropolis, IL facilities' pond mud calciner area. Access was restricted to the area by requiring respiratory protection to be worn.
"Average airborne concentrations during the following 24 hour period were 7.19 E -11 microcuries per cubic centimeter which exceeds the administrative limit of 5 E -12 microcuries per cubic centimeter. Natural uranium dust was the isotope involved.
"There was no known effect to employees. This event is being entered into the facilities corrective action program."
* * * UPDATE AT 1020 EDT ON 07/01/09 FROM BOB STOKES TO S. SANDIN * * *
The licensee is retracting this report based on the following:
"[The licensee is] withdraw[ing] the event reported June 25th, 2009 Event Number 45163. Following a review of the circumstances associated with the report [the licensee] determined that the event did not meet the criteria as described in 10CFR40.60(b). The event review determined that the contamination event was expected. And the area DID have a respiratory protection requirement in place at the time of the elevated air activity."
The licensee informed NRC Region 2 (John Pelchat). Notified R2DO (Musser) and NMSS (Easton).
Power Reactor
Event Number: 45161
Facility: BRAIDWOOD
Region: 3 State: IL
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: SCOTT BUTLER
HQ OPS Officer: MARK ABRAMOVITZ
Region: 3 State: IL
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: SCOTT BUTLER
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 06/24/2009
Notification Time: 19:02 [ET]
Event Date: 06/24/2009
Event Time: 16:39 [CDT]
Last Update Date: 06/24/2009
Notification Time: 19:02 [ET]
Event Date: 06/24/2009
Event Time: 16:39 [CDT]
Last Update Date: 06/24/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
ANN MARIE STONE (R3DO)
ANN MARIE STONE (R3DO)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
ILLINOIS DEPARTMENT OF NATURAL RESOURCES NOTIFIED OF A FISH KILL
"At 1639 CDT on 6/24/09, it was discovered that a fish kill took place in the Braidwood Station's cooling lake due to increased temperature. As summer air temperature increased, the cooling lake temperature increased above 93 degrees F, the threshold at which species susceptible to increased temperature begin to perish. It was communicated to the Illinois Department of Natural Resources (IDNR) that a fish kill has occurred. This notification is being made in accordance with the Exelon Reportability Manual section SAF 1.9, Braidwood Station Facility Operating License Appendix B Section 4.1,'Unusual or Important Environmental Events', and 10CFR50.72(b)(2)(xi)."
See also EN #45151 for similar event.
The licensee notified the NRC Resident Inspector.
"At 1639 CDT on 6/24/09, it was discovered that a fish kill took place in the Braidwood Station's cooling lake due to increased temperature. As summer air temperature increased, the cooling lake temperature increased above 93 degrees F, the threshold at which species susceptible to increased temperature begin to perish. It was communicated to the Illinois Department of Natural Resources (IDNR) that a fish kill has occurred. This notification is being made in accordance with the Exelon Reportability Manual section SAF 1.9, Braidwood Station Facility Operating License Appendix B Section 4.1,'Unusual or Important Environmental Events', and 10CFR50.72(b)(2)(xi)."
See also EN #45151 for similar event.
The licensee notified the NRC Resident Inspector.
Power Reactor
Event Number: 45156
Facility: FITZPATRICK
Region: 1 State: NY
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: JOHN WALKOWIAK
HQ OPS Officer: DAN LIVERMORE
Region: 1 State: NY
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: JOHN WALKOWIAK
HQ OPS Officer: DAN LIVERMORE
Notification Date: 06/24/2009
Notification Time: 11:19 [ET]
Event Date: 06/24/2009
Event Time: 00:00 [EDT]
Last Update Date: 06/24/2009
Notification Time: 11:19 [ET]
Event Date: 06/24/2009
Event Time: 00:00 [EDT]
Last Update Date: 06/24/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
PAMELA HENDERSON (R1DO)
PAMELA HENDERSON (R1DO)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
LOSS OF TONE ALERT RADIOS
"At 0945 on June 24, 2009, with the James A. Fitzpatrick (JAF) Nuclear Power Plant operating at 100% reactor power, Oswego County Emergency Management notified JAF that the National Weather Service had notified them that the Tone Alert Radios had been out of service since 0845.
"This impacts the ability to readily notify a portion of the Emergency Planning Zone (EPZ) population for the Nine Mile Point and JAF Nuclear Power Plants. This failure meets NRC 8-hour reporting criterion 10CFR.50.72(b)(3)(xiii).
"The National Weather Service is currently working to determine the cause of the failure and time frame for system restoration.
"The County alert sirens which also function as part of the public prompt notification system remain operable.
"The loss of the Tone Alert Radios constitutes a significant loss of emergency off-site communications ability. Compensatory measures have been verified to be available should the prompt notification system be needed. This consists of utilizing the hyper reach system which is a reverse 911 feature available from the county 911 center. Local Law Enforcement personnel are also available for 'Route Alerting' of the affected areas of the EPZ.
"The event has been entered into the corrective action program and the NRC Resident Inspector has been briefed and the State PSC will also be notified."
See Event Notice #45157 for Nine Mile Point report.
"At 0945 on June 24, 2009, with the James A. Fitzpatrick (JAF) Nuclear Power Plant operating at 100% reactor power, Oswego County Emergency Management notified JAF that the National Weather Service had notified them that the Tone Alert Radios had been out of service since 0845.
"This impacts the ability to readily notify a portion of the Emergency Planning Zone (EPZ) population for the Nine Mile Point and JAF Nuclear Power Plants. This failure meets NRC 8-hour reporting criterion 10CFR.50.72(b)(3)(xiii).
"The National Weather Service is currently working to determine the cause of the failure and time frame for system restoration.
"The County alert sirens which also function as part of the public prompt notification system remain operable.
"The loss of the Tone Alert Radios constitutes a significant loss of emergency off-site communications ability. Compensatory measures have been verified to be available should the prompt notification system be needed. This consists of utilizing the hyper reach system which is a reverse 911 feature available from the county 911 center. Local Law Enforcement personnel are also available for 'Route Alerting' of the affected areas of the EPZ.
"The event has been entered into the corrective action program and the NRC Resident Inspector has been briefed and the State PSC will also be notified."
See Event Notice #45157 for Nine Mile Point report.
Power Reactor
Event Number: 45157
Facility: NINE MILE POINT
Region: 1 State: NY
Unit: [1] [2] []
RX Type: [1] GE-2,[2] GE-5
NRC Notified By: CHRISTOPHER GRAPES
HQ OPS Officer: DAN LIVERMORE
Region: 1 State: NY
Unit: [1] [2] []
RX Type: [1] GE-2,[2] GE-5
NRC Notified By: CHRISTOPHER GRAPES
HQ OPS Officer: DAN LIVERMORE
Notification Date: 06/24/2009
Notification Time: 11:48 [ET]
Event Date: 06/24/2009
Event Time: 00:00 [EDT]
Last Update Date: 06/24/2009
Notification Time: 11:48 [ET]
Event Date: 06/24/2009
Event Time: 00:00 [EDT]
Last Update Date: 06/24/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
PAMELA HENDERSON (R1DO)
PAMELA HENDERSON (R1DO)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
LOSS OF TONE ALERT RADIOS
"At 0945 on June 24, 2009, with the Nine Mile Point (NMP) Nuclear Power Plant operating at 100% reactor power, Oswego County Emergency Management notified NMP that the National Weather Service had notified them that the Tone Alert Radios had been out of service since 0845.
"This impacts the ability to readily notify a portion of the Emergency Planning Zone (EPZ) population for the NMP and James A. Fitzpatrick Nuclear Power Plants. This failure meets NRC 8-hour reporting criterion 10CFR.50.72(b)(3)(xiii).
"The National Weather Service is currently working to determine the cause of the failure and time frame for system restoration.
"The County alert sirens which also function as part of the public prompt notification system remain operable.
"The loss of the Tone Alert Radios constitutes a significant loss of emergency off-site communications ability. Compensatory measures have been verified to be available should the prompt notification system be needed. This consists of utilizing the hyper reach system which is a reverse 911 feature available from the county 911 center. Local Law Enforcement personnel are also available for 'Route Alerting' of the affected areas of the EPZ.
"The event has been entered into the corrective action program and the NRC Resident Inspector has been briefed and the State PSC will also be notified."
See Event Notice # 45156 James A. Fitzpatrick Nuclear Power Plant report.
"At 0945 on June 24, 2009, with the Nine Mile Point (NMP) Nuclear Power Plant operating at 100% reactor power, Oswego County Emergency Management notified NMP that the National Weather Service had notified them that the Tone Alert Radios had been out of service since 0845.
"This impacts the ability to readily notify a portion of the Emergency Planning Zone (EPZ) population for the NMP and James A. Fitzpatrick Nuclear Power Plants. This failure meets NRC 8-hour reporting criterion 10CFR.50.72(b)(3)(xiii).
"The National Weather Service is currently working to determine the cause of the failure and time frame for system restoration.
"The County alert sirens which also function as part of the public prompt notification system remain operable.
"The loss of the Tone Alert Radios constitutes a significant loss of emergency off-site communications ability. Compensatory measures have been verified to be available should the prompt notification system be needed. This consists of utilizing the hyper reach system which is a reverse 911 feature available from the county 911 center. Local Law Enforcement personnel are also available for 'Route Alerting' of the affected areas of the EPZ.
"The event has been entered into the corrective action program and the NRC Resident Inspector has been briefed and the State PSC will also be notified."
See Event Notice # 45156 James A. Fitzpatrick Nuclear Power Plant report.
Agreement State
Event Number: 46981
Rep Org: NEW YORK CITY BUREAU OF RAD HEALTH
Licensee: LONG ISLAND COLLEGE HOSPITAL
Region: 1
City: BROOKLYN State: NY
County:
License #: 91-2443-01
Agreement: Y
Docket:
NRC Notified By: GENE MISKIN
HQ OPS Officer: CHARLES TEAL
Licensee: LONG ISLAND COLLEGE HOSPITAL
Region: 1
City: BROOKLYN State: NY
County:
License #: 91-2443-01
Agreement: Y
Docket:
NRC Notified By: GENE MISKIN
HQ OPS Officer: CHARLES TEAL
Notification Date: 06/24/2011
Notification Time: 12:41 [ET]
Event Date: 06/24/2009
Event Time: 00:00 [EDT]
Last Update Date: 06/24/2011
Notification Time: 12:41 [ET]
Event Date: 06/24/2009
Event Time: 00:00 [EDT]
Last Update Date: 06/24/2011
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
CHRISTOPHER CAHILL (R1DO)
ANGELA MCINTOSH (FSME)
CHRISTOPHER CAHILL (R1DO)
ANGELA MCINTOSH (FSME)
AGREEMENT STATE REPORT - PATIENT INJECTED WITH WRONG ISOTOPE
The following information was obtained from New York City via email:
"On 6/24/09, a patient was brought to the Nuclear Medicine Department for a myocardial viability exam and was to be injected with Thallium-201.
"The Nuclear Medicine Technologist instead injected the patient with Gallium-67 and immediately realized his mistake. The Gallium vial was right next to the Thallium vial in the storage case. The Head of Nuclear Medicine was informed. He then explained the situation to the patient and advised the patient to take a mild laxative to reduce radiation dose to the large intestine. The event was documented in the patient's chart, and the referring physician was informed.
"Consequences: The estimated absorbed total body dose was 0.5200 rads and the dose to the liver was estimated at 1.2600 rads. The viability study was rescheduled.
"Corrective actions taken: The Policy and Procedures Manual was revised to include specific instructions about double checking that the correct radioisotope was being chosen; training was conducted by the Radiation Safety Officer; and a sign was posted in the lab listing the steps that must be observed before injecting any patient with radioisotopes.
"An inspection was conducted by the Office of Radiological Health on 7/16/09 and the inspector found that the licensee had made a timely report to the [New York City Bureau of Radiation Health (NYCBRH)], and the corrective actions taken were appropriate and effective. This case has been closed by the NYCBRH.
"A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient."
The following information was obtained from New York City via email:
"On 6/24/09, a patient was brought to the Nuclear Medicine Department for a myocardial viability exam and was to be injected with Thallium-201.
"The Nuclear Medicine Technologist instead injected the patient with Gallium-67 and immediately realized his mistake. The Gallium vial was right next to the Thallium vial in the storage case. The Head of Nuclear Medicine was informed. He then explained the situation to the patient and advised the patient to take a mild laxative to reduce radiation dose to the large intestine. The event was documented in the patient's chart, and the referring physician was informed.
"Consequences: The estimated absorbed total body dose was 0.5200 rads and the dose to the liver was estimated at 1.2600 rads. The viability study was rescheduled.
"Corrective actions taken: The Policy and Procedures Manual was revised to include specific instructions about double checking that the correct radioisotope was being chosen; training was conducted by the Radiation Safety Officer; and a sign was posted in the lab listing the steps that must be observed before injecting any patient with radioisotopes.
"An inspection was conducted by the Office of Radiological Health on 7/16/09 and the inspector found that the licensee had made a timely report to the [New York City Bureau of Radiation Health (NYCBRH)], and the corrective actions taken were appropriate and effective. This case has been closed by the NYCBRH.
"A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient."