EVENT REPORTS FOR
05/26/2009 - 05/27/2009

EVENT NUMBERS
4509745110

Power Reactor
Event Number: 45097
Facility: SEQUOYAH
Region: 2     State: TN
Unit: [] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: BRUCE BUCH
HQ OPS Officer: JOHN KNOKE
Notification Date: 05/27/2009
Notification Time: 22:12 [ET]
Event Date: 05/27/2009
Event Time: 19:04 [EDT]
Last Update Date: 05/27/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
GEORGE HOPPER (R2DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 A/R Y 100 Power Operation 0 Hot Standby
Event Text
REACTOR TRIP FROM POWER RANGE HIGH NEUTRON FLUX RATE

"At approximately 1904 on 05/27/09, Sequoyah Unit 2 received an Automatic Reactor trip on Power Range High Neutron Rate Reactor Trip. The automatic trip occurred during severe weather and lightning onsite. ESF functions initiated as designed including Aux Feed Water auto-start and automatic Feedwater isolation. All control rods fully inserted. The plant is currently being maintained in Mode 3 at approximately 547 degrees F 2235 PSIG. Decay heat is being removed by the Auxiliary Feedwater system and Steam Dump valves.

"The cause of the Power Range Neutron Flux High Rate Reactor Trip is not known at this time and investigation is ongoing.

"Unit 1 remains at 100% power".

No relief or safety valves lifted. The electrical lineup is normal and the 2B Diesel Generator is tagged out for maintenance.

The licensee has contacted the NRC Resident Inspector.


Power Reactor
Event Number: 45110
Facility: WATTS BAR
Region: 2     State: TN
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: GREGORY EVANS
HQ OPS Officer: HOWIE CROUCH
Notification Date: 06/01/2009
Notification Time: 18:06 [ET]
Event Date: 05/27/2009
Event Time: 19:05 [EDT]
Last Update Date: 06/01/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(C) - POT UNCNTRL RAD REL 50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
GEORGE HOPPER (R2DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
BOTH TRAINS OF AUXILIARY BUILDING GAS TREATMENT SYSTEM RENDERED INOPERABLE

"On May 27, 2009, Plant Operations was shutting down the Auxiliary Building General Ventilation system [ABGTS] as a compensatory measure in response to an historical deficiency that was identified in the surveillance procedure for conducting TS SR 3.7.12.4. The building's general ventilation was being shut down to place the plant in a known tested configuration to ensure continued safe operation while plans were being developed to properly perform SR 3.7.12.4. While shutting down the building's ventilation system, the operator shut down the building's supply fans followed by the shut down of building's exhaust fans. This sequence resulted in an unacceptable differential pressure condition across a set of Auxiliary Building Secondary Containment Enclosure (ABSCE) doors. Upon identification of the failed doors at 1905 EDT on May 27, the plant entered TS Condition 3.7.12.B for 2 trains of ABGTS being inoperable. Repairs to re-establish the integrity of the ABSCE were immediately initiated and TS Condition 3.7.12.B was exited at 2239 EDT, approximately 3 and 1/2 hours later.

"The reportability of this condition was not recognized at the time of this event. Based upon a review subsequent to the event on June 1, 2009, this event was determined to be reportable under 10 CFR 50.72(b)(3)(v)(C) and (D) as a condition that could have prevented the safety function of structures or systems that are needed to: (C) Control the release of radioactive material; or (D) Mitigate the consequences of an accident.

"The licensee has notified the NRC Resident Inspector."