Event Notification Report for May 25, 2009

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
05/24/2009 - 05/25/2009

EVENT NUMBERS
4509245216

Power Reactor
Event Number: 45092
Facility: QUAD CITIES
Region: 3     State: IL
Unit: [1] [] []
RX Type: [1] GE-3,[2] GE-3
NRC Notified By: DAVE GEEVER
HQ OPS Officer: JOHN KNOKE
Notification Date: 05/25/2009
Notification Time: 21:32 [ET]
Event Date: 05/25/2009
Event Time: 16:50 [CDT]
Last Update Date: 05/25/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(ii)(B) - UNANALYZED CONDITION
Person (Organization):
RICHARD SKOKOWSKI (R3DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Cold Shutdown 0 Cold Shutdown
Event Text
INOPERABLE RCIC PRIMARY CONTAINMENT ISOLATION VALVES

"The Reactor Core Isolation Cooling (RCIC) system tripped on high turbine exhaust discharge pressure during surveillance testing on May 24, 2009. Following the surveillance it was identified that the containment (torus) inboard stop check valve in the RCIC turbine exhaust line could not be closed, necessitating the shutdown of Unit 1 to perform repairs on this inboard isolation valve. At 1650 hours on May 25, 2009, with the unit shutdown, inspections revealed that the inboard isolation valve could not close due to [the presence of] valve material originating from the containment (torus) outboard swing check isolation valve in the turbine exhaust line. Given the inspection findings it has been concluded that neither the inboard stop check valve or the outboard swing check valve in the RCIC turbine exhaust line would have performed their primary containment isolation function while the unit was at power, [thus] impacting containment integrity. As a result, this event is being reported in accordance with 10 CFR 50.72 (b)(3)(ii) for a degraded or unanalyzed condition. The inboard and outboard containment isolation valves in the RCIC turbine exhaust line will be repaired prior to unit startup. The NRC Resident Inspector has been notified of this condition."


Power Reactor
Event Number: 45216
Facility: DRESDEN
Region: 3     State: IL
Unit: [] [] [3]
RX Type: [1] GE-1,[2] GE-3,[3] GE-3
NRC Notified By: PAUL SALGADO
HQ OPS Officer: CHARLES TEAL
Notification Date: 07/21/2009
Notification Time: 15:27 [ET]
Event Date: 05/25/2009
Event Time: 16:15 [CDT]
Last Update Date: 07/21/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
50.73(a)(1) - INVALID SPECIF SYSTEM ACTUATION
Person (Organization):
DAVID HILLS (R3DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
3 N Y 100 Power Operation 100 Power Operation
Event Text
OPTIONAL 60-DAY REPORT OF INVALID SPECIFIED SYSTEM ACTUATION

"On May 25, 2009, at 1615, a Unit 3 control fuse failed open causing multiple containment isolation valves for the atmospheric sampling system and containment ventilation/purge systems to close on a loss of power to the logic system. No actual valid containment isolation signals were received or processed by the containment isolation logic. Since this was an invalid signal, a telephone notification to the NRC Operations Center may be provided within 60 days after discovery of the event instead of submitting a written Licensee Event Report. [10 CFR 50.73(a)(2)(iv)(A)].

"This phone notification is being made in lieu of a written 60 day LER as allowed in 10 CFR 50.73(a)(1) to report the invalid actuation of multiple containment isolation valves that occurred as described above. The fuse is associated with the inboard containment isolation logic. This is considered a partial actuation and all components operated as expected. Troubleshooting identified that a relay failed and, in turn, had caused the fuse to open. The relay and fuse were replaced and the systems restored to their normal lineup. The NRC Resident has been informed that this notification is being made.

"No further notifications or reports will be issued."