Event Notification Report for May 20, 2009
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
05/19/2009 - 05/20/2009
EVENT NUMBERS
45090450914508345201
Fuel Cycle Facility
Event Number: 45090
Facility: WESTINGHOUSE ELECTRIC CORPORATION
Region: 2 State: SC
Unit: [] [] []
RX Type: URANIUM FUEL FABRICATION
NRC Notified By: GERARD COUTURE
HQ OPS Officer: DONALD NORWOOD
Region: 2 State: SC
Unit: [] [] []
RX Type: URANIUM FUEL FABRICATION
NRC Notified By: GERARD COUTURE
HQ OPS Officer: DONALD NORWOOD
Notification Date: 05/22/2009
Notification Time: 12:42 [ET]
Event Date: 05/20/2009
Event Time: 15:00 [EDT]
Last Update Date: 09/16/2009
Notification Time: 12:42 [ET]
Event Date: 05/20/2009
Event Time: 15:00 [EDT]
Last Update Date: 09/16/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
MATTHEW HAHN (ILTA)
ANTHONY McMURTRAY (IRD)
JAMES RUBENSTONE (NMSS)
ROBERT HAAG (R2DO)
MATTHEW HAHN (ILTA)
ANTHONY McMURTRAY (IRD)
JAMES RUBENSTONE (NMSS)
ROBERT HAAG (R2DO)
LICENSE CONDITION REPORT INVOLVING SNM ACCOUNTABILITY
"Facility: Westinghouse Electric Company LLC (WEC), Commercial Fuel Fabrication Facility, Columbia SC,
low enriched (less than or equal to 5.0 wt.% U-235) fuel fabricator for commercial light water reactors. License: SNM-1107.
"Time and Date of Event: May 20, 2009, approximately 1500.
"Reason for Notification & Sequence of Events:
"Notification made based on Materials License Number SNM-1107, Safeguards Conditions Section 1.0 Material Control and Accounting, SG-1.1 which states in part; 'The licensee shall follow Chapters 1.0 through 9.0 of its 'Fundamental Nuclear Material Control Plan for the Columbia Fuel Fabrication Facility.' The Fundamental Nuclear Material Control Plan, Section 2.2.2 contains specific requirements for notification for issues related to resolving item and/or material control anomalies.
"The Environment, Health and Safety (EH&S) Department was informed that a small scrap fuel pellet container containing uranium, which is Special Nuclear Material (SNM), could not be readily located. The anomaly was identified by operations personnel conducting a routine weekly audit of SNM-bearing items. Initial investigation and search efforts did not locate the SNM, which was in a small container (approximately 8 inches in diameter x 8 inches tall) used for routine processing, commonly called a 'polypak.'
"Personnel independent of the affected area conducted a Material Balance Inventory, which concluded that the SNM did not leave the area. The Material Balance results and findings were reviewed by an independent contractor, a Material Control and Accounting expert who agreed with the conclusion and methodology used. Based on this material balance and other investigative actions conducted by WEC, there is no indication that the material left the affected area, and the SNM was processed through the normal scrap process flow.
"Safety Basis: There are no actual or potential health or safety consequences to the workers, the public or the environment.
"As Found Condition: See Reason for Notification.
"Summary of Activity
- Operations in the affected manufacturing area were halted and the area was extensively and systematically searched by Operations, Management and EH&S personnel.
- The empty container was located within the affected manufacturing area.
- Retraining on item control requirements for production personnel was completed prior to restart of production activities.
- Enhanced accountability and control measures for item control of scrap containers was completed prior to restart of production activities.
- An investigative review team was assembled and interviewed personnel in the affected manufacturing areas to determine the cause of the item control discrepancy.
- The event was entered into the WEC Corrective Action Process and a formal Root Cause Analysis was completed.
- Interim corrective actions have been completed and longer term corrective actions have been initiated to reduce the likelihood of a repeat occurrence based on the results and recommendations of the Root Cause Analysis."
"Facility: Westinghouse Electric Company LLC (WEC), Commercial Fuel Fabrication Facility, Columbia SC,
low enriched (less than or equal to 5.0 wt.% U-235) fuel fabricator for commercial light water reactors. License: SNM-1107.
"Time and Date of Event: May 20, 2009, approximately 1500.
"Reason for Notification & Sequence of Events:
"Notification made based on Materials License Number SNM-1107, Safeguards Conditions Section 1.0 Material Control and Accounting, SG-1.1 which states in part; 'The licensee shall follow Chapters 1.0 through 9.0 of its 'Fundamental Nuclear Material Control Plan for the Columbia Fuel Fabrication Facility.' The Fundamental Nuclear Material Control Plan, Section 2.2.2 contains specific requirements for notification for issues related to resolving item and/or material control anomalies.
"The Environment, Health and Safety (EH&S) Department was informed that a small scrap fuel pellet container containing uranium, which is Special Nuclear Material (SNM), could not be readily located. The anomaly was identified by operations personnel conducting a routine weekly audit of SNM-bearing items. Initial investigation and search efforts did not locate the SNM, which was in a small container (approximately 8 inches in diameter x 8 inches tall) used for routine processing, commonly called a 'polypak.'
"Personnel independent of the affected area conducted a Material Balance Inventory, which concluded that the SNM did not leave the area. The Material Balance results and findings were reviewed by an independent contractor, a Material Control and Accounting expert who agreed with the conclusion and methodology used. Based on this material balance and other investigative actions conducted by WEC, there is no indication that the material left the affected area, and the SNM was processed through the normal scrap process flow.
"Safety Basis: There are no actual or potential health or safety consequences to the workers, the public or the environment.
"As Found Condition: See Reason for Notification.
"Summary of Activity
- Operations in the affected manufacturing area were halted and the area was extensively and systematically searched by Operations, Management and EH&S personnel.
- The empty container was located within the affected manufacturing area.
- Retraining on item control requirements for production personnel was completed prior to restart of production activities.
- Enhanced accountability and control measures for item control of scrap containers was completed prior to restart of production activities.
- An investigative review team was assembled and interviewed personnel in the affected manufacturing areas to determine the cause of the item control discrepancy.
- The event was entered into the WEC Corrective Action Process and a formal Root Cause Analysis was completed.
- Interim corrective actions have been completed and longer term corrective actions have been initiated to reduce the likelihood of a repeat occurrence based on the results and recommendations of the Root Cause Analysis."
General Information or Other
Event Number: 45091
Rep Org: TEXAS DEPARTMENT OF HEALTH
Licensee: DOW CHEMICAL COMPANY
Region: 4
City: FREEPORT State: TX
County:
License #: 00451
Agreement: Y
Docket:
NRC Notified By: ART TUCKER
HQ OPS Officer: JOHN KNOKE
Licensee: DOW CHEMICAL COMPANY
Region: 4
City: FREEPORT State: TX
County:
License #: 00451
Agreement: Y
Docket:
NRC Notified By: ART TUCKER
HQ OPS Officer: JOHN KNOKE
Notification Date: 05/22/2009
Notification Time: 13:30 [ET]
Event Date: 05/20/2009
Event Time: 00:00 [CDT]
Last Update Date: 05/22/2009
Notification Time: 13:30 [ET]
Event Date: 05/20/2009
Event Time: 00:00 [CDT]
Last Update Date: 05/22/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
WILLIAM JONES (R4DO)
WILLIAM JONES (R4DO)
AGREEMENT STATE REPORT - SHUTTER ON GAUGE INOPERATIVE
"On March 21, 2009, at 1050 AM, the Agency [Texas Department of Health] received a report from the licensee that while performing the biannual test on a Ronan Engineering nuclear gauge, model # SA-1, containing an original activity of 100 millicuries (calculated current activity of 75 millicuries) of Cesium (Cs) - 137, the shutter failed to close. The gauge is installed on the side of a vessel approximately 50 feet above ground and is used for level detection. A dose rate measurement taken at the gauge indicated 0.03 millirem per hour, and poses no risk of radiation exposure to their workers. The manufacturer has been contacted to provide corrective maintenance on the shutter."
Texas Incident # I-8635I
"On March 21, 2009, at 1050 AM, the Agency [Texas Department of Health] received a report from the licensee that while performing the biannual test on a Ronan Engineering nuclear gauge, model # SA-1, containing an original activity of 100 millicuries (calculated current activity of 75 millicuries) of Cesium (Cs) - 137, the shutter failed to close. The gauge is installed on the side of a vessel approximately 50 feet above ground and is used for level detection. A dose rate measurement taken at the gauge indicated 0.03 millirem per hour, and poses no risk of radiation exposure to their workers. The manufacturer has been contacted to provide corrective maintenance on the shutter."
Texas Incident # I-8635I
General Information or Other
Event Number: 45083
Rep Org: MINNESOTA DEPARTMENT OF HEALTH
Licensee: AMERICAN ENGINEERING AND TESTING
Region: 3
City: ST PAUL State: MN
County:
License #:
Agreement: Y
Docket:
NRC Notified By: CRAIG VERKE
HQ OPS Officer: JOHN KNOKE
Licensee: AMERICAN ENGINEERING AND TESTING
Region: 3
City: ST PAUL State: MN
County:
License #:
Agreement: Y
Docket:
NRC Notified By: CRAIG VERKE
HQ OPS Officer: JOHN KNOKE
Notification Date: 05/20/2009
Notification Time: 17:26 [ET]
Event Date: 05/20/2009
Event Time: 15:30 [CDT]
Last Update Date: 05/20/2009
Notification Time: 17:26 [ET]
Event Date: 05/20/2009
Event Time: 15:30 [CDT]
Last Update Date: 05/20/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
RICHARD SKOKOWSKI (R3DO)
LYDIA CHANG (FSME)
RICHARD SKOKOWSKI (R3DO)
LYDIA CHANG (FSME)
AGREEMENT STATE REPORT - STUCK RADIOGRAPHY SOURCE
The State sent this event via fax:
"Radiography was being performed by American Engineering and Testing at Midwest Tank in Big Lake, Minnesota when after performing an exposure, the 41.4 curie, Ir-192 source would not retract back into the camera. The radiographer attempted numerous times to retract the source and was unsuccessful. The radiographer and radiography's assistant performed surveys and reset the boundaries. The RSO for the Minnesota license was called at 1300. The RSO had performed the source retrieval and it was secured back in the camera at 1420. MDH received a call at 1530 providing notification of the incident. Preliminary cause was a kink in the guide tube. Minnesota RSO who performed the retrieval will be notified tomorrow for additional information. A written report will be required within 30 days of notification."
The State sent this event via fax:
"Radiography was being performed by American Engineering and Testing at Midwest Tank in Big Lake, Minnesota when after performing an exposure, the 41.4 curie, Ir-192 source would not retract back into the camera. The radiographer attempted numerous times to retract the source and was unsuccessful. The radiographer and radiography's assistant performed surveys and reset the boundaries. The RSO for the Minnesota license was called at 1300. The RSO had performed the source retrieval and it was secured back in the camera at 1420. MDH received a call at 1530 providing notification of the incident. Preliminary cause was a kink in the guide tube. Minnesota RSO who performed the retrieval will be notified tomorrow for additional information. A written report will be required within 30 days of notification."
General Information or Other
Event Number: 45201
Rep Org: MINNESOTA DEPARTMENT OF HEALTH
Licensee: AMERICAN ENGINEERING AND TESTING
Region: 3
City: State: MN
County:
License #: 1089-204-62
Agreement: Y
Docket:
NRC Notified By: GEORGE JOHNS
HQ OPS Officer: HOWIE CROUCH
Licensee: AMERICAN ENGINEERING AND TESTING
Region: 3
City: State: MN
County:
License #: 1089-204-62
Agreement: Y
Docket:
NRC Notified By: GEORGE JOHNS
HQ OPS Officer: HOWIE CROUCH
Notification Date: 07/13/2009
Notification Time: 15:00 [ET]
Event Date: 05/20/2009
Event Time: 13:00 [CDT]
Last Update Date: 07/13/2009
Notification Time: 15:00 [ET]
Event Date: 05/20/2009
Event Time: 13:00 [CDT]
Last Update Date: 07/13/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
KENNETH RIEMER (R3DO)
ANGELA MCINTOSH (FSME)
KENNETH RIEMER (R3DO)
ANGELA MCINTOSH (FSME)
MINNESOTA AGREEMENT STATE REPORT - UNABLE TO RETRACT RADIOGRAPHY CAMERA SOURCE
The following information was obtained from the State of Minnesota via email:
"On Wednesday, May 20, 2009, at approximately 1300 hrs, a licensee was performing radiography at a temporary job site using a 41 Curie Ir-192 source when the stand holding the guide tube fell from its secured position and landed on the guide tube near the camera, crimping the guide tube. The radiographer attempted numerous times to retract the source and was unsuccessful. The radiographer performed radiation surveys to reset the boundaries and contacted the management. The Radiation Safety Officer was also contacted.
"The NDT [Non-Destructive Testing] manager used steel plates for shielding in order to disconnect the guide tube from the camera. Once disconnected, the NDT manager proceeded to the collimator end of the guide tube and pulled the guide tube to allow the source to pass through the crimped portion. When the source passed through the kink, the radiographer cranked the source into its shielded position. The NDT manger received 121 mrem, the radiographer received approximately 40 mrem. Leak tests results indicate that the source was not effected. The guide tube has been discarded.
"The root cause of the event was determined to be that the radiographers failed to ensure that all four legs of the magnets on the ring stand used to support the guide tube were not in contact with metal due to the curvature of the surface. The weight of the guide tube caused the stand to fall and to crimp the guide tube. "
This is an update to EN #45083, dated May 25, 2009.
The following information was obtained from the State of Minnesota via email:
"On Wednesday, May 20, 2009, at approximately 1300 hrs, a licensee was performing radiography at a temporary job site using a 41 Curie Ir-192 source when the stand holding the guide tube fell from its secured position and landed on the guide tube near the camera, crimping the guide tube. The radiographer attempted numerous times to retract the source and was unsuccessful. The radiographer performed radiation surveys to reset the boundaries and contacted the management. The Radiation Safety Officer was also contacted.
"The NDT [Non-Destructive Testing] manager used steel plates for shielding in order to disconnect the guide tube from the camera. Once disconnected, the NDT manager proceeded to the collimator end of the guide tube and pulled the guide tube to allow the source to pass through the crimped portion. When the source passed through the kink, the radiographer cranked the source into its shielded position. The NDT manger received 121 mrem, the radiographer received approximately 40 mrem. Leak tests results indicate that the source was not effected. The guide tube has been discarded.
"The root cause of the event was determined to be that the radiographers failed to ensure that all four legs of the magnets on the ring stand used to support the guide tube were not in contact with metal due to the curvature of the surface. The weight of the guide tube caused the stand to fall and to crimp the guide tube. "
This is an update to EN #45083, dated May 25, 2009.