Event Notification Report for March 15, 2009
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
03/14/2009 - 03/15/2009
EVENT NUMBERS
45206
Hospital
Event Number: 45206
Rep Org: NANTICOKE COOK MEMORIAL HOSPITAL
Licensee: NANTICOKE COOK MEMORIAL HOSPITAL
Region: 1
City: SEAFORD State: DE
County:
License #: 07-17618-01
Agreement: N
Docket:
NRC Notified By: MATTHEW RAJOTTE
HQ OPS Officer: CHARLES TEAL
Licensee: NANTICOKE COOK MEMORIAL HOSPITAL
Region: 1
City: SEAFORD State: DE
County:
License #: 07-17618-01
Agreement: N
Docket:
NRC Notified By: MATTHEW RAJOTTE
HQ OPS Officer: CHARLES TEAL
Notification Date: 07/15/2009
Notification Time: 12:54 [ET]
Event Date: 03/15/2009
Event Time: 00:00 [EDT]
Last Update Date: 07/15/2009
Notification Time: 12:54 [ET]
Event Date: 03/15/2009
Event Time: 00:00 [EDT]
Last Update Date: 07/15/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
35.3045(a)(1) - DOSE <> PRESCRIBED DOSAGE
10 CFR Section:
35.3045(a)(1) - DOSE <> PRESCRIBED DOSAGE
Person (Organization):
HAROLD GRAY (R1DO)
ANGELA MCINTOSH (FSME)
HAROLD GRAY (R1DO)
ANGELA MCINTOSH (FSME)
MEDICAL UNDEREXPOSURE DURING BRACHYTHERAPY
"A prostate seed implant was performed on March 5th, 2009, using needles preloaded with I-125 seeds. After implanting a total of 61 seeds, 22 seeds were found and then retrieved from the bladder. The patient later returned for a pelvic CT for post implant dosimetry. This dosimetry revealed an under dosing of the prostate with a D90 dose less than 80% of the prescribed dose. The seed distribution error was caused by the position of the needles in respect to depth when the seeds were released. The patient received no ill effect, but requires further therapeutic radiation in order to complete the prescription. The patient is currently scheduled for a second seed implant to complete the therapy."
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
"A prostate seed implant was performed on March 5th, 2009, using needles preloaded with I-125 seeds. After implanting a total of 61 seeds, 22 seeds were found and then retrieved from the bladder. The patient later returned for a pelvic CT for post implant dosimetry. This dosimetry revealed an under dosing of the prostate with a D90 dose less than 80% of the prescribed dose. The seed distribution error was caused by the position of the needles in respect to depth when the seeds were released. The patient received no ill effect, but requires further therapeutic radiation in order to complete the prescription. The patient is currently scheduled for a second seed implant to complete the therapy."
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.