Event Notification Report for March 02, 2009

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
03/01/2009 - 03/02/2009

EVENT NUMBERS
449404488644885

Power Reactor
Event Number: 44940
Facility: PEACH BOTTOM
Region: 1     State: PA
Unit: [] [3] []
RX Type: [2] GE-4,[3] GE-4
NRC Notified By: DAVE FOSS
HQ OPS Officer: JASON KOZAL
Notification Date: 03/27/2009
Notification Time: 08:40 [ET]
Event Date: 03/02/2009
Event Time: 11:55 [EDT]
Last Update Date: 03/27/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
50.73(a)(1) - INVALID SPECIF SYSTEM ACTUATION
Person (Organization):
JAMES DWYER (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
3 N Y 100 Power Operation 100 Power Operation
Event Text
INVALID PRIMARY CONTAINMENT ISOLATION SIGNAL DUE TO MAINTENANCE ERROR

"This 60-day report, as allowed by 10 CFR 50.73(a)(1), is being made under the reporting requirement in 10CFR50.73(a)(2)(iv)(A) to describe an unplanned, invalid actuation of specified systems, specifically the Unit 3 Primary Containment Isolation System (PCIS). On 3/2/09, at approximately 1155 hours, Unit 3 experienced an invalid PCIS partial isolation. Associated with the momentary shorting of a terminal lead during maintenance, a fuse was blown and power was lost to nine Primary Containment Isolation Valves (PCIVs). This resulted in two of the PCIVs re-positioning to the closed position. The re-positioned PCIVs were the AO-3-07B-3509 (Inner Drywell Exhaust Valve) and the AO-3-16-5235 (Instrument Nitrogen System Suction Valve). Closure of these valves affected the Containment Atmospheric Control (CAC), Containment Atmospheric Dilution (CAD) and Containment Instrument Nitrogen systems. Closure of these valves was the expected response for loss of power to this portion of the PCIS control circuitry. The fuse was replaced and the valves were restored to an operable condition by 1235 hours on 3/2/09.

"The invalid PCIS isolation was a result of the momentary shorting of an energized terminal lead associated with preventive maintenance to replace a pressure switch associated with PCIV AO-3-07B-3519 (Nitrogen Supply Purge Valve).

"This issue has been entered into the site Corrective Action Program (CR 887441) for evaluation and implementation of further corrective actions. The NRC resident has been informed of this notification."


Power Reactor
Event Number: 44886
Facility: CALVERT CLIFFS
Region: 1     State: MD
Unit: [1] [2] []
RX Type: [1] CE,[2] CE
NRC Notified By: BRUCE SHICK
HQ OPS Officer: HOWIE CROUCH
Notification Date: 03/02/2009
Notification Time: 13:02 [ET]
Event Date: 03/02/2009
Event Time: 11:35 [EST]
Last Update Date: 03/07/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION 50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
CHRISTOPHER CAHILL (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N N 0 Refueling 0 Refueling
Event Text
WEATHER RELATED LOSS OF AUTOMATIC NOTIFICATION SYSTEM SIRENS

"Sixteen of seventy three ANS [Automatic Notification System] sirens are inoperable for failure to pass the weekly growl test. The following sirens that are OOS are located in Calvert County (9 of 50 sirens), St. Mary's County (5 of 17 sirens) and Dorchester County (2 of 6 sirens)."

The failures were most likely due to the weather conditions. The licensee has notified the local governments.

The licensee has notified the NRC Resident Inspector.

* * * UPDATE AT 0750 EST ON 03/07/09 FROM BRUCE SHICK TO S. SANDIN * * *

The licensee is updating this report to show that all sirens were restored to service as of 1000 EST on 3/6/09.

The licensee informed the NRC Resident Inspector. Notified R1DO (Hansell).


Power Reactor
Event Number: 44885
Facility: BRUNSWICK
Region: 2     State: NC
Unit: [1] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: TOM HACKLER
HQ OPS Officer: JASON KOZAL
Notification Date: 03/02/2009
Notification Time: 12:57 [ET]
Event Date: 03/02/2009
Event Time: 09:15 [EST]
Last Update Date: 03/02/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
RANDY MUSSER (R2)
ANTHONY McMURTRAY (IRD)
JOHN THORPE (NRR)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N N 0 Cold Shutdown 0 Cold Shutdown
Event Text
ONSITE FATALITY

"A contract employee associated with the Unit 2 refueling outage died this morning from an apparent heart attack. The death was not the result of any industrial safety issue and did not occur in a contaminated area. The individual was treated by the onsite first responders who administered CPR and AED (automatic external defibrillator). He was transported via ambulance to Dosher Memorial hospital where he was pronounced dead at 0915."

"OSHA is being notified of the event under the requirements of 29 CFR 1904."

The licensee notified the NRC Resident Inspector.