Event Notification Report for January 21, 2009
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
01/20/2009 - 01/21/2009
General Information or Other
Event Number: 44792
Rep Org: FLORIDA BUREAU OF RADIATION CONTROL
Licensee: CENTRAL TESTING LABORATORY
Region: 1
City: LEESBURG State: FL
County:
License #: 3187-2
Agreement: Y
Docket:
NRC Notified By: STEVE FURNACE
HQ OPS Officer: MARK ABRAMOVITZ
Licensee: CENTRAL TESTING LABORATORY
Region: 1
City: LEESBURG State: FL
County:
License #: 3187-2
Agreement: Y
Docket:
NRC Notified By: STEVE FURNACE
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 01/21/2009
Notification Time: 12:40 [ET]
Event Date: 01/21/2009
Event Time: 12:00 [EST]
Last Update Date: 01/21/2009
Notification Time: 12:40 [ET]
Event Date: 01/21/2009
Event Time: 12:00 [EST]
Last Update Date: 01/21/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
WILLIAM COOK (R1)
MICHELE BURGESS (FSME)
WILLIAM COOK (R1)
MICHELE BURGESS (FSME)
AGREEMENT STATE REPORT - DAMAGED MOISTURE DENSITY GAUGE
The following information was received from the State of Florida via fax:
"Troxler gauge run over by dump truck at job site. Sources allegedly in shielded position. State inspector sent to investigate. Upper control rod bent, some damage to outer container. Sources in shielded position, radiation readings nominal. Gauge being transported to Troxler representative in Orlando for repair. No further action will be taken by this office."
Sources: 40 mCi Am:Be, 8 mCi Cs-137
Florida Report: FL 09-006
The following information was received from the State of Florida via fax:
"Troxler gauge run over by dump truck at job site. Sources allegedly in shielded position. State inspector sent to investigate. Upper control rod bent, some damage to outer container. Sources in shielded position, radiation readings nominal. Gauge being transported to Troxler representative in Orlando for repair. No further action will be taken by this office."
Sources: 40 mCi Am:Be, 8 mCi Cs-137
Florida Report: FL 09-006
Power Reactor
Event Number: 44793
Facility: BRUNSWICK
Region: 2 State: NC
Unit: [1] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: JAMES BURKE
HQ OPS Officer: MARK ABRAMOVITZ
Region: 2 State: NC
Unit: [1] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: JAMES BURKE
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 01/21/2009
Notification Time: 16:00 [ET]
Event Date: 01/21/2009
Event Time: 13:00 [EST]
Last Update Date: 01/21/2009
Notification Time: 16:00 [ET]
Event Date: 01/21/2009
Event Time: 13:00 [EST]
Last Update Date: 01/21/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
10 CFR Section:
50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
RANDY MUSSER (R2)
RANDY MUSSER (R2)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
LOSS OF CONTROL ROOM AIR CONDITIONING AND EMERGENCY VENTILATION SYSTEM
"At approximately 1300 hours on January 21, 2009, a loss of control air to the Control Room ventilation system occurred. As a result, the three Control Room Air Conditioning subsystems required by Technical Specification (TS) 3.7.4, 'Control Room Air Conditioning (AC) System,' and the two Control Room Emergency Ventilation subsystems required by TS 3.7.3, 'Control Room Emergency Ventilation (CREV) System,' became inoperable. As a result, this condition could have prevented the fulfillment of the safety function for these systems. Because Brunswick has a shared control room, Unit 1 and Unit 2 entered TS 3.7.3 Required Action B.1, for two CREV subsystems inoperable (i.e. be in Mode 3 within 12 hours) and TS 3.7.4, Required Action E.1, for three Control Room AC subsystems inoperable (i.e. enter LCO 3.0.3 immediately). Operability of the Control Room AC subsystems and CREV subsystems was restored and related LCO's including TS 3.0.3 were exited at 1429 hours following the restoration of control air to the Control Room ventilation systems.
"No power reduction took place as a result of the LCO 3.0.3 entry. This report applies to both Units 1 and 2 and is being made in accordance with 10 CFR 50.72(b)(3)(v)(D), as a condition that at the time of discovery could have prevented fulfillment of the safety function of systems that are needed to mitigate the consequences of an accident.
"The safety significance of this event is considered minimal. The condition existed for approximately 1 hour and 29 minutes. Plant staff took immediate action to return the equipment to service. For the brief time the Control Room AC and CREV systems were inoperable, performance of plant personnel and equipment in the Control Room was not adversely affected.
"The control air to the Control Room ventilation systems has been restored to service. This allowed restarting the Control Room air conditioning units. Both CREV trains and the three Control Room air conditioning units have been restored to operable. TS 3.7.3 and TS 3.7.4 Actions have been exited."
The licensee notified the NRC Resident Inspector.
"At approximately 1300 hours on January 21, 2009, a loss of control air to the Control Room ventilation system occurred. As a result, the three Control Room Air Conditioning subsystems required by Technical Specification (TS) 3.7.4, 'Control Room Air Conditioning (AC) System,' and the two Control Room Emergency Ventilation subsystems required by TS 3.7.3, 'Control Room Emergency Ventilation (CREV) System,' became inoperable. As a result, this condition could have prevented the fulfillment of the safety function for these systems. Because Brunswick has a shared control room, Unit 1 and Unit 2 entered TS 3.7.3 Required Action B.1, for two CREV subsystems inoperable (i.e. be in Mode 3 within 12 hours) and TS 3.7.4, Required Action E.1, for three Control Room AC subsystems inoperable (i.e. enter LCO 3.0.3 immediately). Operability of the Control Room AC subsystems and CREV subsystems was restored and related LCO's including TS 3.0.3 were exited at 1429 hours following the restoration of control air to the Control Room ventilation systems.
"No power reduction took place as a result of the LCO 3.0.3 entry. This report applies to both Units 1 and 2 and is being made in accordance with 10 CFR 50.72(b)(3)(v)(D), as a condition that at the time of discovery could have prevented fulfillment of the safety function of systems that are needed to mitigate the consequences of an accident.
"The safety significance of this event is considered minimal. The condition existed for approximately 1 hour and 29 minutes. Plant staff took immediate action to return the equipment to service. For the brief time the Control Room AC and CREV systems were inoperable, performance of plant personnel and equipment in the Control Room was not adversely affected.
"The control air to the Control Room ventilation systems has been restored to service. This allowed restarting the Control Room air conditioning units. Both CREV trains and the three Control Room air conditioning units have been restored to operable. TS 3.7.3 and TS 3.7.4 Actions have been exited."
The licensee notified the NRC Resident Inspector.
General Information or Other
Event Number: 44803
Rep Org: NC DIV OF RADIATION PROTECTION
Licensee: CHARLOTTE MECKLENBERG HOSPITAL AUTHORITY
Region: 1
City: CHARLOTTE State: NC
County:
License #: 060-0014-3
Agreement: Y
Docket:
NRC Notified By: SHARN JEFFRIES
HQ OPS Officer: HOWIE CROUCH
Licensee: CHARLOTTE MECKLENBERG HOSPITAL AUTHORITY
Region: 1
City: CHARLOTTE State: NC
County:
License #: 060-0014-3
Agreement: Y
Docket:
NRC Notified By: SHARN JEFFRIES
HQ OPS Officer: HOWIE CROUCH
Notification Date: 01/23/2009
Notification Time: 13:42 [ET]
Event Date: 01/21/2009
Event Time: 11:30 [EST]
Last Update Date: 01/23/2009
Notification Time: 13:42 [ET]
Event Date: 01/21/2009
Event Time: 11:30 [EST]
Last Update Date: 01/23/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
WILLIAM COOK (R1)
MICHELE BURGESS (FSME)
WILLIAM COOK (R1)
MICHELE BURGESS (FSME)
AGREEMENT STATE REPORT - LEAKING I-125 BRACHYTHERAPY SEEDS
The following information was obtained from the State of North Carolina by fax:
"[The] Licensee stores unused I-125 Brachytherapy seeds in bulk with other unused I-125 sources. A routine leak test of the bulked I-125 seeds in October yielded no removable contamination. A routine leak test of the bulked I-125 seeds in January 2009 showed removable contamination: 2.3-2.8 microCuries.
"The licensee has 223 total iodine brachytherapy seeds stored in the storage container and cannot determine which seeds are leaking. 164 seeds were added to the storage container since the October leak test.
"[The] Licensee has contacted [the] manufacturer (Core Oncology) to return seeds and perform assay on seeds to determine which seeds are indeed leaking.
"The licensee cannot ascertain if the I-125 seeds were damaged at patient loading (by licensee physicians) or at the manufacturer."
It is unknown if any patients have been contaminated. All patients are being contacted for bioassays.
Total activity for all the seeds to be returned is 78.71mCi (@0.3 mCi per seed).
NC Incident No. 09-10
The following information was obtained from the State of North Carolina by fax:
"[The] Licensee stores unused I-125 Brachytherapy seeds in bulk with other unused I-125 sources. A routine leak test of the bulked I-125 seeds in October yielded no removable contamination. A routine leak test of the bulked I-125 seeds in January 2009 showed removable contamination: 2.3-2.8 microCuries.
"The licensee has 223 total iodine brachytherapy seeds stored in the storage container and cannot determine which seeds are leaking. 164 seeds were added to the storage container since the October leak test.
"[The] Licensee has contacted [the] manufacturer (Core Oncology) to return seeds and perform assay on seeds to determine which seeds are indeed leaking.
"The licensee cannot ascertain if the I-125 seeds were damaged at patient loading (by licensee physicians) or at the manufacturer."
It is unknown if any patients have been contaminated. All patients are being contacted for bioassays.
Total activity for all the seeds to be returned is 78.71mCi (@0.3 mCi per seed).
NC Incident No. 09-10