Skip to main content

Event Notification Report for January 15, 2009

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
01/14/2009 - 01/15/2009

EVENT NUMBERS
4477944780

Hospital
Event Number: 44779
Rep Org: VA NATIONAL HEALTH PHYSICS PROGRAM
Licensee: VA MEDICAL CENTER
Region: 1
City: DURHAM   State: NC
County:
License #: 03-23853-01VA
Agreement: Y
Docket:
NRC Notified By: THOMAS HUSTON
HQ OPS Officer: VINCE KLCO
Notification Date: 01/15/2009
Notification Time: 14:10 [ET]
Event Date: 01/15/2009
Event Time: 00:00 [EST]
Last Update Date: 01/15/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
35.3045(a)(1) - DOSE <> PRESCRIBED DOSAGE
Person (Organization):
ART BURRITT (R1)
ANDREA KOCK (FSME)
KENNETH O'BRIEN (R3)
Event Text
TREATMENT SITE DOSE LESS THAN PRESCRIBED

"A medical event was discovered on January 15, 2009, for a patient treated at the VA Medical Center, Durham, North Carolina.

"This medical event involved a patient who had undergone permanent implant prostate seed brachytherapy using iodine-125 seeds. The resulting seed distribution in the patient was associated with a D90 dose to the treatment site that was less than 80% of the prescribed dose. The circumstances are interpreted to meet the definition of a medical event under 10 CFR 35.3045(a)(1)(i).

"A 15-day written report on this medical event will be submitted to NRC Region III. [The licensee] notified [the] NRC Project Manager, Cassandra Frazier (NRC Region III), of this medical event.

"Department of Veterans Affairs has a Master Materials License (MML) from the NRC: License No. 03-23853-01VA. Permits are issued under the MML to VA facilities. The VA submits reports to the NRC through the VHA's National Health Physics Program office located in North Little Rock, AR. Address of permittee involved in this event: VA Medical Center, 508 Fulton Street, Durham, North Carolina 27705. VHA permit number of permittee involved in event: Permit No. 32-01134-01."

A Medical Event may indicate potential problems in a medical facilities use of radioactive materials. It does not necessarily result in harm to the patient.


General Information or Other
Event Number: 44780
Rep Org: MISSISSIPPI DIV OF RAD HEALTH
Licensee: JANX INTEGRITY GROUP
Region: 4
City: HATTIESBURG   State: MS
County:
License #: 21-16560-01
Agreement: Y
Docket:
NRC Notified By: JAYSON MOAK
HQ OPS Officer: JASON KOZAL
Notification Date: 01/16/2009
Notification Time: 13:16 [ET]
Event Date: 01/15/2009
Event Time: 00:00 [CST]
Last Update Date: 03/06/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
RYAN LANTZ (R4)
ANGELA MCINTOSH (FSME)
Event Text
AGREEMENT STATE - FIRE INVOLVING RADIOGRAPHY CAMERA

The following was provided by the State via e-mail:

"On 1-15-09, DRH was notified by the Forrest County ERC that JANX Integrity Group had an accident with one of their darkroom trucks off Hwy 59 N., in Hattiesburg, MS. The driver for JANX struck a tree off the side of the interstate causing the vehicle to catch fire. The driver then left the scene of the accident. The radiography camera, SPEC-150, SN 150 (Ir-192, 65 Ci), was not discovered until the fire department saw a 'Caution Radiation Area' sign in the bed of the darkroom truck after extinguishing the fire. Surveys were conducted by firefighter personnel for their safety and to pinpoint the location of the radioactive device in the darkroom truck. The Forrest County ERC contacted an industrial radiography company and MS licensee located in Hattiesburg to take possession of the camera and secure it in their storage vault. The radiography camera was retrieved off the darkroom truck and out of its locked storage box by the MS licensee. The radiography camera was surveyed by the MS licensee before being transported to their storage facility. On 1-15-09, JANX retrieved the radiography camera out of storage for transport back to the manufacturer to assess the damage.

"DRH took surveys of the darkroom truck and the radiography camera. Radiation measurements were as follows: 24 mR/hr at the surface of the camera; 4 mR/hr at 6 inches from the camera; levels were background at the vehicle. DRH coordinated the receipt of radiography camera between JANX and a MS licensee for delivery back to the manufacturer."

MS report number - MS 09001

* * * UPDATE FROM JAYSON MOAK TO HOWIE CROUCH AT 1739 ON 1/23/09 * * *

The following was provided by the State via e-mail:

"On 1-15-09, swipes were taken on the camera and revealed no removable contamination. Leak test results for the source and DU shielding were received from SPEC on 1-23-09 and also revealed no removable contamination."

Notified FSME EO (Chang) and R4DO (Farnholtz).


* * * UPDATE FROM JAYSON MOAK (VIA EMAIL) TO JASON KOZAL AT 1232 ON 1/28/09 * * *

The following was provided by the State via e-mail:

"On 1-28-09, DRH received the SPEC - 150, Exposure Device S/N 150 Final Inspection Certificate from SPEC. The camera met the requirements contained in 10 CFR 34.20, ANSI N432 1980, USA/9263/B(U)-96 and SPEC's QA Program approval number 102."

Notified FSME EO (White) and R4DO (Cain).


* * * UPDATE FROM JAYSON MOAK (VIA EMAIL) TO JOHN KNOKE AT 1718 ON 02/20/09 * * *

The following information was provided by the state via e-mail:

"Source was Ir-192, 65 Ci, S/N PJ1606, Source Model G-60."

Notified FSME EO (Vontill) and R4DO (Powers).


* * * UPDATE FROM JAYSON MOAK TO JOE O'HARA VIA EMAIL AT 1704 ON 02/23/09 * * *

The following information was provided by the state via e-mail:

The State of Mississippi has taken enforcement action and cited their licensee with four violations.

Notified R4DO (Gaddy) and FSME EO (Vontill).


* * * UPDATE FROM JAYSON MOAK TO PETE SNYDER VIA EMAIL AT 1003 ON 03/06/09 * * *

The following information was provided by the state via e-mail:

"On 3/5/09 [the State of Mississippi] received a written report from JANX Integrity Group."

This incident has been closed on 3/5/09.

Notified R4DO (Proulx), and FSME EO (McIntosh).