Event Notification Report for December 16, 2008
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
12/15/2008 - 12/16/2008
Fuel Cycle Facility
Event Number: 44724
Facility: GLOBAL NUCLEAR FUEL - AMERICAS
Region: 2 State: NC
Unit: [] [] []
RX Type: URANIUM FUEL FABRICATION
Comments: LEU CONVERSION (UF6 TO UO2)
LEU FABRICATION
LWR COMMERICAL FUEL
NRC Notified By: SCOTT MURRAY
HQ OPS Officer: HOWIE CROUCH
Region: 2 State: NC
Unit: [] [] []
RX Type: URANIUM FUEL FABRICATION
Comments: LEU CONVERSION (UF6 TO UO2)
LEU FABRICATION
LWR COMMERICAL FUEL
NRC Notified By: SCOTT MURRAY
HQ OPS Officer: HOWIE CROUCH
Notification Date: 12/16/2008
Notification Time: 16:23 [ET]
Event Date: 12/16/2008
Event Time: 06:00 [EST]
Last Update Date: 12/16/2008
Notification Time: 16:23 [ET]
Event Date: 12/16/2008
Event Time: 06:00 [EST]
Last Update Date: 12/16/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
70.50(b)(2) - SAFETY EQUIPMENT FAILURE
10 CFR Section:
70.50(b)(2) - SAFETY EQUIPMENT FAILURE
Person (Organization):
JAY HENSON (R2)
PETER HABIGHORST (NMSS)
JAY HENSON (R2)
PETER HABIGHORST (NMSS)
CRITICALITY WARNING SYSTEM DISABLED
"At approximately 0600 on 12/16/2008, the horns of the inside Criticality Warning System (CWS) covering the Fuel Manufacturing Operation (FMO) were discovered to be in manual mode. On 12/12/08 at approximately 0700, the horns had been taken out of automatic mode and placed in manual mode as part of system maintenance activities at 0700 and inadvertently remained in this condition until this morning at 0600. According to a preliminary investigation, it appears that following maintenance on 12/12/08, incomplete system restoration left the automatic horn function disabled but the detection system remained operational.
"Once identified, the system was immediately restored to the automatic mode and the inside FMO CWS system was returned to normal operation. Follow-up tests have confirmed that the warning system horns are fully operational.
"The event is being reported within 24-hours pursuant to 10CFR70.50(b)(2) as an event in which safety equipment was disabled."
During the time that the warning system was disabled, there were no conditions that would have resulted in warning system activation. Corrective actions have been taken to prevent re-occurrence. The licensee will be notifying NRC Region 2 as well as State and local governments.
"At approximately 0600 on 12/16/2008, the horns of the inside Criticality Warning System (CWS) covering the Fuel Manufacturing Operation (FMO) were discovered to be in manual mode. On 12/12/08 at approximately 0700, the horns had been taken out of automatic mode and placed in manual mode as part of system maintenance activities at 0700 and inadvertently remained in this condition until this morning at 0600. According to a preliminary investigation, it appears that following maintenance on 12/12/08, incomplete system restoration left the automatic horn function disabled but the detection system remained operational.
"Once identified, the system was immediately restored to the automatic mode and the inside FMO CWS system was returned to normal operation. Follow-up tests have confirmed that the warning system horns are fully operational.
"The event is being reported within 24-hours pursuant to 10CFR70.50(b)(2) as an event in which safety equipment was disabled."
During the time that the warning system was disabled, there were no conditions that would have resulted in warning system activation. Corrective actions have been taken to prevent re-occurrence. The licensee will be notifying NRC Region 2 as well as State and local governments.
Hospital
Event Number: 44727
Rep Org: CJW MEDICAL CENTER
Licensee: CJW MEDICAL CENTER
Region: 1
City: RICHMOND State: VA
County:
License #: 45-15249-01
Agreement: N
Docket:
NRC Notified By: RUTH MICHAUD
HQ OPS Officer: JASON KOZAL
Licensee: CJW MEDICAL CENTER
Region: 1
City: RICHMOND State: VA
County:
License #: 45-15249-01
Agreement: N
Docket:
NRC Notified By: RUTH MICHAUD
HQ OPS Officer: JASON KOZAL
Notification Date: 12/17/2008
Notification Time: 16:07 [ET]
Event Date: 12/16/2008
Event Time: 15:00 [EST]
Last Update Date: 12/17/2008
Notification Time: 16:07 [ET]
Event Date: 12/16/2008
Event Time: 15:00 [EST]
Last Update Date: 12/17/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
35.3045(a)(2) - DOSE > SPECIFIED EFF LIMITS
10 CFR Section:
35.3045(a)(2) - DOSE > SPECIFIED EFF LIMITS
Person (Organization):
RICHARD BARKLEY (R1)
CHRIS EINGERG (FSME)
RICHARD BARKLEY (R1)
CHRIS EINGERG (FSME)
MEDICAL EVENT - MISADMINISTRATION
A patient was prescribed a gammaknife procedure to treat trigeminal neuralgia on the right side of the face and the left was treated in error. The prescribed dose was 40 Gray (Gy) to 50% isodose. The patient was notified of the misadministration. There are no expected adverse effects to the patient.
The licensee is continuing to investigate this incident to determine the cause of the misadministration and the total dose to the patient.
A Medical Event may indicate potential problems in a medical facilities use of radioactive materials. It does not necessarily result in harm to the patient.
A patient was prescribed a gammaknife procedure to treat trigeminal neuralgia on the right side of the face and the left was treated in error. The prescribed dose was 40 Gray (Gy) to 50% isodose. The patient was notified of the misadministration. There are no expected adverse effects to the patient.
The licensee is continuing to investigate this incident to determine the cause of the misadministration and the total dose to the patient.
A Medical Event may indicate potential problems in a medical facilities use of radioactive materials. It does not necessarily result in harm to the patient.