Event Notification Report for December 12, 2008
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
12/11/2008 - 12/12/2008
Power Reactor
Event Number: 44716
Facility: ARKANSAS NUCLEAR
Region: 4 State: AR
Unit: [1] [] []
RX Type: [1] B&W-L-LP,[2] CE
NRC Notified By: CHUCK OLSON
HQ OPS Officer: STEVE SANDIN
Region: 4 State: AR
Unit: [1] [] []
RX Type: [1] B&W-L-LP,[2] CE
NRC Notified By: CHUCK OLSON
HQ OPS Officer: STEVE SANDIN
Notification Date: 12/12/2008
Notification Time: 11:48 [ET]
Event Date: 12/12/2008
Event Time: 08:55 [CST]
Last Update Date: 12/12/2008
Notification Time: 11:48 [ET]
Event Date: 12/12/2008
Event Time: 08:55 [CST]
Last Update Date: 12/12/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL
Person (Organization):
JACK WHITTEN (R4)
JACK WHITTEN (R4)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | M/R | Y | 32 | Power Operation | 0 | Hot Standby |
UNIT 1 WAS MANUALLY TRIPPED FROM 32% POWER DUE TO AN ABNORMAL ROD PATTERN
"Following startup from refueling outage 1R21, Arkansas Nuclear One Unit 1 was holding stable at 32% reactor power in order to perform Nuclear Instrumentation (NI) calibration. Control Rod Drive Mechanism (CRDM) control was in automatic with the controlling group (Group 7) at approximately 75% withdrawn. Control room operators received an asymmetric rod alarm and noted abnormal rod pattern on Group 7 with reactor power lowering. At this point, operations manually scrammed the reactor. Post trip response was normal and the plant is stable in Mode 3. Reactor Coolant System pressure is approximately 2155 psig and temperature is approximately 550 degree F. Post Transient Review is in progress."
Unit 1 is in a normal post trip electrical lineup. No primary or secondary reliefs lifted during the transient. Auxiliary feedwater was placed in service to supply the Steam Generators for decay heat removal via the Main Condenser.
The licensee informed both the State and NRC Resident Inspector.
"Following startup from refueling outage 1R21, Arkansas Nuclear One Unit 1 was holding stable at 32% reactor power in order to perform Nuclear Instrumentation (NI) calibration. Control Rod Drive Mechanism (CRDM) control was in automatic with the controlling group (Group 7) at approximately 75% withdrawn. Control room operators received an asymmetric rod alarm and noted abnormal rod pattern on Group 7 with reactor power lowering. At this point, operations manually scrammed the reactor. Post trip response was normal and the plant is stable in Mode 3. Reactor Coolant System pressure is approximately 2155 psig and temperature is approximately 550 degree F. Post Transient Review is in progress."
Unit 1 is in a normal post trip electrical lineup. No primary or secondary reliefs lifted during the transient. Auxiliary feedwater was placed in service to supply the Steam Generators for decay heat removal via the Main Condenser.
The licensee informed both the State and NRC Resident Inspector.
Power Reactor
Event Number: 44717
Facility: CALLAWAY
Region: 4 State: MO
Unit: [1] [] []
RX Type: [1] W-4-LP
NRC Notified By: GREG KIMMINAU
HQ OPS Officer: HOWIE CROUCH
Region: 4 State: MO
Unit: [1] [] []
RX Type: [1] W-4-LP
NRC Notified By: GREG KIMMINAU
HQ OPS Officer: HOWIE CROUCH
Notification Date: 12/12/2008
Notification Time: 14:36 [ET]
Event Date: 12/12/2008
Event Time: 10:42 [CST]
Last Update Date: 12/12/2008
Notification Time: 14:36 [ET]
Event Date: 12/12/2008
Event Time: 10:42 [CST]
Last Update Date: 12/12/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
10 CFR Section:
50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
JACK WHITTEN (R4)
JACK WHITTEN (R4)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | N | 0 | Hot Standby | 0 | Hot Standby |
INADVERTENT VALID REACTOR TRIP AND FEEDWATER ISOLATION SIGNALS DUE TO MAINTENANCE
"Valid Reactor Trip and Manual Initiation of Auxiliary Feedwater While in MODE 3"
"At 1042 on 12/12/2008, while in Mode 3, a valid reactor trip signal was generated during I&C maintenance activities on intermediate range nuclear instrument SENI0036. This resulted in a feedwater isolation signal. Reactor Operators manually started both motor driven auxiliary feedwater pumps to maintain steam generator levels. These pumps were started prior to receiving an Auxiliary Feedwater Actuation. Plant is stable in Mode 3. Normal feedwater supply has been restored. The cause of the reactor trip is understood.
"All systems functioned normally in response to plant conditions.
"The NRC Resident Inspector has been notified."
"Valid Reactor Trip and Manual Initiation of Auxiliary Feedwater While in MODE 3"
"At 1042 on 12/12/2008, while in Mode 3, a valid reactor trip signal was generated during I&C maintenance activities on intermediate range nuclear instrument SENI0036. This resulted in a feedwater isolation signal. Reactor Operators manually started both motor driven auxiliary feedwater pumps to maintain steam generator levels. These pumps were started prior to receiving an Auxiliary Feedwater Actuation. Plant is stable in Mode 3. Normal feedwater supply has been restored. The cause of the reactor trip is understood.
"All systems functioned normally in response to plant conditions.
"The NRC Resident Inspector has been notified."